Zhenhai Wang

Zhenhai Wang

Auto-generated profile, based on publicly available information

Zhenhai Wang

Department of Energy and Power Engineering, Tsinghua University Department of Energy and Power Engeering, Beijing, 100084, CHINA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2019 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
ZWZhenhai Wang
Zhenhai Wang
PFPengfei Fu
Pengfei Fu
Xing ChaoXing Chao
Xing Chao
A baseline reduction algorithm for determining gas temperature and concentration from absorption spectra with interfering features using direct absorption spectroscopy is proposed. Empirical baselines are obtained through non-absorbing baseline transform, and background subtraction is done by reducing the first three components of the orthogonal polynomial expansion of the measured spectra. The algorithm is first validated by numerical simulation using the absorption lines of CO ( R (9) and R (17)) located between 2179 and 2180 cm −1 , which provides a correct estimation of temperature and CO concentration. Then the method is demonstrated in premixed CH 4 /air flat flame. The temperature is determined with a precision of 20 K, and the detection limit for CO is 400 ppm at 1835 K with 4.70% CO and 4.70% CO 2 interference. Both the simulation and experimental results show that the algorithm is well suited for interpreting absorption spectra with neighbouring interference features as are often encountered in practical combustion environments.

10 July 2020 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
ZWZhenhai Wang
Zhenhai Wang
PFPengfei Fu
Pengfei Fu
LHLingyun Hou
Lingyun Hou
Xing ChaoXing Chao
Xing Chao
The design, optimization and demonstration of a compact, single-ended laser absorption sensor based on a diffuse-wall-reflected signal is presented for temperature and H 2 O concentration measurements in a kerosene-fuelled aero-combustor. The challenges of laser measurements in such harsh, practical combustion environments involve strong beam-steering, low signal-to-noise ratio (SNR), and constrained optical access. We present here a detailed characterization and optimization procedure of a single-ended optical configuration using a holed off-axis parabolic mirror as the pitch and catch optics, and the coked wall surface of the combustor as a diffuse reflector. A near-infrared distributed-feedback diode laser near 1.4 µm scanned at 1 kHz for direct absorption detection was used to access two H 2 O transitions for concentration and temperature measurement. An optical system design and adaptive Savitzky–Golay signal processing algorithm were used for noise suppression and SNR amelioration. The sensor was demonstrated under practical conditions in a kerosene-fuelled swirl combustor. High signal fidelity was achieved and allowed for a single-scan H 2 O concentration detection limit of 122 ppm MHz −1/2 , despite a low reflected laser intensity level of ~50 µW. In situ , time-resolved measurements detected temperatures ranging from ~1100 K to 1300 K, and H 2 O concentration ranging from ~8% to 12% as global equivalence ratio varied between 0.2 and 0.45. The results revealed an expected trend while demonstrating much faster response and less delay versus a comparative thermocouple. This successful field manifestation provides direct proof for the robustness and reliability of a diffuse-reflection-based single-ended sensor system in engine combustion chamber environments.

9 August 2022 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
NZNing Zhu
Ning Zhu
ZXZe Xu
Ze Xu
ZWZhenhai Wang
Zhenhai Wang
ZSZihao Song
Zihao Song
WWWeitian Wang
Weitian Wang
Xing ChaoXing Chao
Xing Chao
Broadband precision spectroscopy is an invaluable tool for high-fidelity species diagnostics as well as multispecies sensing in complex real-world environments. However, concurrent demands for broad spectral coverage and high spectral resolution present great challenges to both optical measurement systems and data acquisition and processing. We report methodological and experimental demonstration of a midinfrared direct optical frequency comb (OFC) spectrometer, using Fourier-transform spectroscopy (FTS) with a compressed sensing (CS) algorithm. Efficient data sampling and accurate spectral recovery are demonstrated with comb-teeth-resolving resolution of 0.0083cm−1 (250 MHz) over a spectral range of 300cm−1. The v3 band of CH4 is measured, and validated against conventional FTS results and theoretical calculations. Studies on the effect of compression ratio show that a compressed interferogram using as few as 2% of the regular sample points can effectively recover the high-resolution broadband spectrum with an accuracy of 1.9%. The developed diagnostic system bears promising potential for accurate, real-time, multispecies sensing that is pressingly needed for studying the dynamics of complex multicomponent systems.

14 April 2025 in Optics Express
Verified
Journal Article
Closed access
ZWZhenhai Wang
Zhenhai Wang
NZNing Zhu
Ning Zhu
WWWeitian Wang
Weitian Wang
Xing ChaoXing Chao
Xing Chao
This paper demonstrates what we believe to be a new WMS m-FID technique based on cepstral analysis, incorporating wavelength modulation spectroscopy (WMS) with a modified form of the time-domain molecular free-induction decay (m-FID) signal. Detailed theoretical framework of the WMS m-FID technique, as well as the fitting routine, has been investigated. The proposed WMS m-FID technique is first validated through a static CO gas cell experiment using the CO R(9) absorption line near 2179.7719 cm−1. The fitting error between the measured and best-fit m-FID signals is less than 1.0 %, with integrated absorbance area of relative uncertainty 0.17 %. Time-resolved measurements of CO over a 6-second purge period demonstrate the reliability and robustness of the proposed WMS m-FID approach in comparison with direct absorption spectroscopy (DAS) and WMS-2f/1f techniques. The demonstration of the proposed WMS m-FID approach is further carried out in a premixed CH4/Air laminar flame of a flat-flame burner. The relative fitting residuals between the measured and best-fit m-FID signals remain below 4.0 %, yielding T = 1763 K and XH2O=16.58 % at HAB = 7 mm, with a temperature uncertainty of 30 K and absolute H2O concentration uncertainty of 0.65 %. The average temperature difference between the WMS m-FID and WMS-2f/1f techniques is within 18.0 K (<1.0 % relative), and the H2O concentration difference is within 0.4 % (<2.6 % relative). Additionally, the proposed WMS m-FID technique significantly improves computational efficiency, enabling 22-fold acceleration compared to the time-consuming spectral-fitting routine in standard WMS-2f/1f techniques. Finally, a strictly baseline-free CO measurement is achieved by directly fitting the m-FID signal of the measured transmitted intensity beyond the 3rd-order peak (τ ≥ ~5.7 ns) and the 4th-order peak (τ ≥ ~7.7 ns), with deviations of 2.7 % and 4.4 % from the entire m-FID signal fitting, respectively. Both the static gas-cell and high-temperature flat-flame demonstrations indicate that the proposed WMS m-FID technique enables quantitative, accurate, and baseline-free measurements. It is envisioned that the WMS m-FID technique can be an effective solution for achieving baseline-free, quantitative, in situ monitoring in practical combustion environments.

1 January 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
XCXiaoliang Chen
Xiaoliang Chen
NZNing Zhu
Ning Zhu
WWWeitian Wang
Weitian Wang
ZWZhenhai Wang
Zhenhai Wang
YWYuki Wakata
Yuki Wakata
Xing ChaoXing Chao
Xing Chao
Drop evaporation is a ubiquitous phenomenon that has been studied for over a century. However, the surrounding gas-phase field including the temperature and vapor concentration distribution is not sufficiently studied experimentally. In this paper, a sensor based on tunable laser absorption spectroscopy is designed to study the vapor-phase temperature and concentration distribution of evaporating sessile drops, and data processing method involving data pre-processing and tomographic reconstruction is proposed to realize high-precision, spatially resolved measurement, which was realized by scanning the mechanical galvanometer in the horizontal direction. With free-knot splines smoothing and "denucleated" onion peeling algorithm, temperature and H2O concentration distributions surrounding the evaporated drop at three different substrate plate temperatures are observed. The concentration and temperature in close vicinity to the gas-liquid interface are reconstructed accurately despite the high-gradient changes. Spatial resolution of under 100mm with temporal resolution of 10s has been realized. Quantitative depiction of the temperature and concentration fields shows evidence of convection, and indicates that while the concentration level sharply peaks at the interface, temperature in the close vicinity to the drop shows flattening or even dipping trends. The in situ laser measurement results are validated against contact measurement, theoretical prediction with saturated vapor pressure, and model simulation of COMSOL. Uncertainties have been evaluated based on both repeated measurements and model prediction of input uncertainty propagation. Temperature and concentration measurement uncertainties are estimated to be < 1.5% and < 3.5%, respectively, even though all experiments were performed in open air with non-negligible buoyancy-induced convection.

14 April 2026 in Applied Optics
Verified
Journal Article
Open access
SASyed Tajammul Ahmad
Syed Tajammul Ahmad
ZWZhenhai Wang
Zhenhai Wang
LMLuca Moretti
Luca Moretti
DGDavide Gatti
Davide Gatti
MMMarco Marangoni
Marco Marangoni
AFAamir Farooq
Aamir Farooq
We demonstrate the application of a broadband long-wave infrared dual-comb spectrometer (LWIR-DCS) for gas detection across the molecular fingerprint region (7.5–11.5 µm). As a benchmark, we first validate the spectrometer through broadband single-species measurements of SO 2 , resolving its blended rovibrational transitions around 1111−1259cm −1 (8–9 µm) with excellent agreement to HITRAN simulations. Building on this, we demonstrate simultaneous multispecies detection of CH 4 , N 2 O, and C 2 H 4 , recovering broadband absorption spectra spanning 1000−1250cm −1 (8–10 µm) with a spectral point spacing of 8.34×10 −3 cm −1 . Line-by-line fitting enables accurate extraction of mole fractions and pressure-broadening coefficients for the multispecies mixture, with residuals being within a few percent across the full bandwidth. Together, these results establish the LWIR-DCS as a powerful platform for both single-species and multispecies detection, with applications in environmental sensing, atmospheric chemistry, combustion diagnostics, and industrial process monitoring.