25 March 2020 in IET Generation, Transmission & Distribution
This study presents an algorithm for detection, classification, and location of transmission line faults. A fault index based on features extracted from current signals using the alienation coefficient and Wigner distribution function has been proposed for the detection and classification of faults. Double line and double line to ground faults have been classified from each other using ground fault index based on negative sequence current. Statistical relations are proposed for the estimation of fault location using peak values of the proposed fault index. The results of different case studies established the effectiveness of the algorithm. The algorithm is found to be effective for providing protection to transmission line against various faults. This is achieved using current signals recorded on one terminal of the line. This makes the protection scheme less complex, fast and more economic due to the elimination of the requirement of communication channel and global positioning system synchronisation. The proposed protection scheme is also validated on a real‐time network of transmission utility. The effectiveness of the algorithm is established by comparing performance with reported algorithms.
1 March 2017 in IET Generation, Transmission & Distribution
This study presents a wavelet‐alienation based algorithm for protection of two terminal transmission line. The proposed algorithm makes use of wavelet transform based approximate coefficients of three‐phase voltage and current signals, obtained over a quarter cycle to detect, classify and locate various faults. Detection and classification of these faults are achieved with the help of alienation coefficients of current signals from both the terminals of the transmission line. The approximate coefficients of voltage and current signals, obtained over a quarter cycle, are fed to artificial neural network to locate the faults precisely. The proposed algorithm has been tested successfully for various types of faults with the variations in location, inception angle and fault impedance.
9 June 2020 in IEEE Transactions on Industrial Informatics
The custom power devices play important role for enhancing the power transfer capacity of transmission system. However, these devices introduce challenges of under-reach or over-reach, in the protection of transmission system. This paper introduces a novel, protection algorithm based on wavelet alienation neural technique for STATCOM-compensated transmission system. For detecting and classifying faults, approximate coefficients are computed from the post-fault quarter cycle current waveforms. Fault index, which is summation of Alienation coefficients (computed by approximate coefficients) of both the buses, is computed and compared with the threshold magnitude for detecting and classifying the different faults. For the determination of fault location, Artificial Neural Network (ANN) is applied, with input as three-phase approximate coefficients, evaluated from the voltage and current signals over a time duration of a quarter cycle. Robustness of developed scheme has been validated for various faults at different locations with varying fault impedances and angles of fault incidence.
18 January 2021 in IEEE Access
Fault analysis (detection, classification and location) of transmission network is of great importance in power system. A Wavelet-Alienation-Neural (WAN) technique has been developed for the fault analysis of Unified Power Flow Controller (UPFC) compensated transmission network. The detection and classification of various outages are accomplished by alienation of wavelet based approximate coefficients computed from current signals. The precise location of faults is carried out by an Artificial Neural Network fed from estimated approximate coefficients computed from voltage and current signals of the same quarter cycle. The robustness of the algorithm is proved with the case studies of varying fault locations, sampling frequency, system parameters, effects of noise, fault incipient angle, different control strategies and fault path impedances.
1 August 2018 in Electric Power Systems Research
16 November 2020 in IEEE Transactions on Industrial Informatics
This article presents a $k$ -means clustering and weighted $k$ -nearest neighbor ( $k$ -NN) regression-based algorithm for the protection of transmission line. Three-phase current signals of both the terminals are synchronized and sampled with a sampling frequency of 3.84 kHz. Cumulative differential sum (CDS) is computed by subtracting the samples of current cycle from the previous cycle at both the terminals of transmission line. $k$ -means clustering is applied on CDS to compute two centroids using moving window of width, equal to one cycle. Difference between the absolute values of centroids is computed at both the terminals and represented by the centroid difference (CD). The CD of both the terminals is added to compute the fault index. The computed fault index is used to detect and classify the types of faults. The location of the fault is estimated by the weighted $k$ -NN regression method. Various case studies are performed to validate the robustness of the algorithm for different fault parameters such as fault impedance and fault location. The effect of noise is also considered to check the accuracy of the proposed algorithm in the noisy environment.