Purpose: To investigate differences between positron emission tomography/magnetic resonance imaging (PET/MRI) and PET/computed tomography (PET/CT) in lesion detection and classification in oncological whole-body examinations and to investigate radiation exposure differences between both modalities. Material and Methods: In this prospective, single-center, observational study 1003 oncological examinations (918 patients, mean age 57.8±14.4y) were included. Patients underwent PET/CT and subsequent PET/MRI (149.8±49.7min after tracer administration). Examinations were reviewed by radiologists and nuclear medicine physicians in consensus. Additional findings, characterization of indetermiante findings in PETCT, missed findings in PET/MRI including their clinical relevance and effective dose of both modalities were investigated. McNemar’s test was used to compare lesion detection between both hybrid imaging modalities (p<0.001 indicating statistical significance). Results: Additional information in PET/MRI was reported in 26.3% (264/1003) of examinations compared to PET/CT (p<0.001). Of these, additional malignant findings were detected in 5.3% (53/1003), leading to a change in TNM-staging in 2.9% (29/1003) due to PET/MRI. Definite lesion classification of indeterminate PET/CT findings was possible in 11.1% (111/1003) with PET/MRI. In 2.9% (29/1003), lesions detected in PET/CT were not visible in PET/MRI. Malignant lesions were missed in 1.2% (12/1003) by PET/MRI leading to a change in TNM-staging in 0.5% (5/1003). The estimated mean effective-dose for whole-body PET/CT amounted to 17.6±8.7mSv in comparison to 3.6±1.4mSv in PET/MRI, resulting in a potential dose reduction of 79.6% (p<0.001). Conclusion: PET/MRI improves lesion detection and potentially reduces additional examinations in tumor staging. Especially younger patients may benefit from the clinically relevant dose reduction of PET/MRI compared to PET/CT.
Our data showed significant agreement between response assessments at whole-body diffusion-weighted MRI and fluorine 18 fluorodeoxyglucose PET/MRI after induction chemotherapy; the agreement after ... Background Whole-body diffusion-weighted (DW) MRI can help detect cancer with high sensitivity. However, the assessment of therapy response often requires information about tumor metabolism, which ...
Purpose To investigate how the extent of an ultrasound instructor’s clinical expertise influences the level of hands-on ultrasound competency achieved by clinicians after three-day ultrasound courses in abdominal and emergency ultrasound. The second goal was to determine how physicians in residency rate the sonographic and didactic skills of student instructors compared to medical staff instructors. Method A total of N = 100 residents participating in a 3-day ultrasound workshop were randomly trained either by 15 student instructors or by clinical staff physicians, both with > 2 years of teaching experience. Both instructor groups had previously completed 120 hours of didactic instructor training. Ultrasound competencies were assessed by a standardized objective structured clinical examination (OSCE) of healthy individuals. The sonographic and didactic skills of both instructor groups were rated by questionnaires with six-step Likert items (1 = excellent, 6 = poor). Results The cohort, trained by student instructors, achieved the same scoring level as the second cohort, trained by physician instructors (mean score 76.4, versus 73.7 of max. 100 points, p = 0.28) in the final OSCE. The sonographic qualification was rated for student educators as 1.44 (mean) [1.1–1.62], versus residents 1.46 [1.26–1.61], versus attendings 1.29 [1.05–1.61]. Didactic skill levels were rated without significant differences with means of 1.53, 1.57 and 1.53, respectively. Discussion & Conclusion The didactic competence of student instructors does not differ statistically from the competency levels of experienced physicians. In terms of the acquired ultrasound skills of trainees, our data indicate that student instructors can be as efficient as staff instructors. Therefore, student instructors can be employed as resource-saving ultrasound educators without decreasing the skills level achieved by course participants, provided that they previously underwent a comprehensive didactic and sonographic training program.
Objective: To evaluate the impact of different metal artifact reduction (MAR) algorithms on Hounsfield unit (HU) and standardized uptake values (SUV) in a phantom setting and verify these results in patients with metallic implants undergoing oncological PET/CT examinations. Methods and materials: In this prospective study, PET-CT examinations of 28 oncological patients (14 female, 14 male, mean age 69.5 ± 15.2y) with 38 different metal implants were included. CT datasets were reconstructed using standard weighted filtered back projection (WFBP) without MAR, MAR in image space (MARIS) and iterative MAR (iMAR, hip algorithm). The three datasets were used for PET attenuation correction. SUV and HU measurements were performed at the site of the most prominent bright and dark band artifacts. Differences between HU and SUV values across the different reconstructions were compared using paired t-tests. Bonferroni correction was used to prevent alpha-error accumulation (p < 0.017). Results: For bright band artifacts, MARIS led to a non-significant mean decrease of 12.0% (345 ± 315 HU) in comparison with WFBP (391 ± 293 HU), whereas iMAR led to a significant decrease of 68.3% (125 ± 185 HU, p < 0.017). For SUVmean, MARIS showed no significant effect in comparison with WFBP (WFBP: 0.99 ± 0.40, MARIS: 0.96 ± 0.39), while iMAR led to a significant decrease of 11.1% (0.88 ± 0.35, p < 0.017). Similar results were observed for dark band artifacts. Conclusion: iMAR significantly reduces artifacts caused by metal implants in CT and thus leads to a significant change of SUV measurements in bright and dark band artifacts compared with WFBP and MARIS, thus probably improving PET quantification. Advances in knowledge: The present work indicates that MAR algorithms such as iMAR algorithm in integrated PET/CT scanners are useful to improve CT image quality as well as PET quantification in the evaluation of tracer uptake adjacent to large metal implants. A detailed analysis of oncological patients with various large metal implants using different MAR algorithms in PET/CT has not been conducted yet.