Abdur Rashid

Abdur Rashid

Auto-generated profile, based on publicly available information

Abdur Rashid

Department of Electrical Engineering, COMSATS Institute of Information Technology, Abbottabad, Pakistan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Applied Mathematical Modelling
Verified
Journal Article
Closed access
TNTahir Nazir
Tahir Nazir
Muhammad AbbasMuhammad Abbas
Muhammad Abbas
AIAhmad Izani Md. Ismail
Ahmad Izani Md. Ismail
AMAhmad Abd. Majid
Ahmad Abd. Majid
ARAbdur Rashid
Abdur Rashid

1 July 2014 in Applied Mathematics and Computation
Verified
Journal Article
Closed access
Muhammad AbbasMuhammad Abbas
Muhammad Abbas
AMAhmad Abd. Majid
Ahmad Abd. Majid
AIAhmad Izani Md. Ismail
Ahmad Izani Md. Ismail
ARAbdur Rashid
Abdur Rashid

1 March 2018
Verified
Conference Paper
Closed access
RURahmat Ullah
Rahmat Ullah
ARAbdur Rashid
Abdur Rashid
AHAun Haider
Aun Haider
Zahid UllahZahid Ullah
Zahid Ullah
NANaseer Ahmad
Naseer Ahmad
NRN. U. Rahman
N. U. Rahman
In an electrical power system, the transformer is one of the most important and efficient machines, and to ensure the continuity of power supply utmost care should be taken for its safe operation. Transformers are robust device but they may fail over time due to old age, poor insulation, deterioration of cellulose as well as oil insulation. In addition, there are several elements that may lead to insulation's premature aging and damages; these may include oxygen, heat and moisture contents. transformer oil provides insulation and cooling inside a machine, however there are various factors which affect the insulation strength and smooth flow of the transformer oil over the period of time, so it is therefore very important to observe some of the specific parameters like electrical (specific resistance, dielectric strength, dielectric dissipation factor or tan delta), chemical (Water content, sludge content, acidity) and physical (viscosity, flash point, pour point) to check the effectiveness of the transformer oil Therefore by keeping in mind the factor of reliability, this work presents three field transformers along with application of different diagnostic methods on their oil sample. At the end of this work, the detailed analysis carried out on the basis of effects of temperature, humidity, and loading. Tests are performed to check the appearance, breakdown voltage, water content, acidity, dielectric dissipation or tan delta Dissolved gas analysis (DGA) and kinematic viscosity of the oil samples, results obtained from these tests are then compared to IEC standards to check the effectiveness of the oil samples.

7 November 2013 in Abstract and Applied Analysis
Verified
Journal Article
Open access
PDF file
MGMohammad Ghoreishi
Mohammad Ghoreishi
AIA. I. B. Md. Ismail
A. I. B. Md. Ismail
ARAbdur Rashid
Abdur Rashid
Homotopy analysis method (HAM) is applied to obtain the approximate solution of inner-resonance of tangent cushioning packaging system based on critical components. The solution is obtained in the form of infinite series with components which can be easily calculated. Using a convergence-control parameter, the HAM utilizes a simple method to adjust and control the convergence region of the infinite series solution. The obtained results show that the HAM is a very accurate technique to obtain the approximate solution.