Currently, Pakistan is facing severe energy crises and global warming effects. Hence, there is an urgent need to utilize renewable energy generation. In this context, Pakistan possesses massive wind energy potential across the coastal areas. This paper investigates and numerically analyzes coastal areas’ wind power density potential. Eight different state-of-the-art numerical methods, namely an (a) empirical method, (b) graphical method, (c) wasp algorithm, (d) energy pattern method, (e) moment method, (f) maximum likelihood method, (g) energy trend method, and (h) least-squares regression method, were analyzed to calculate Weibull parameters. We computed Weibull shape parameters (WSP) and Weibull scale parameters (WCP) for four regions: Jiwani, Gwadar, Pasni, and Ormara in Pakistan. These Weibull parameters from the above-mentioned numerical methods were analyzed and compared to find an optimal numerical method for the coastal areas of Pakistan. Further, the following statistical indicators were used to compare the efficiency of the above numerical methods: (i) analysis of variance (), (ii) chi-square (), and (iii) root mean square error (RMSE). The performance validation showed that the energy trend and graphical method provided weak performance for the observed period for four coastal regions of Pakistan. Further, we observed that Ormara is the best and Jiwani is the worst area for wind power generation using comparative analyses for actual and estimated data of wind power density from four regions of Pakistan.
12 October 2017 in IET Generation, Transmission & Distribution
A hybrid scheme for enhancing fault ride through (FRT) capability of doubly fed induction generator under symmetrical and asymmetrical grid faults is presented. The hybrid strategy is composed of switch type fault current limiter (STFCL), braking chopper and energy storage system (ESS). The hybrid scheme guarantees the safety and controllability of rotor side converter and DC‐link capacitor. The proposed FRT scheme has ability to overcome the transients and oscillation produced during the voltage dip. The hybrid strategy is capable of keeping the fault current, DC‐link voltage, rotor current and voltage and electromagnetic torque within the limits and damps the oscillations during the voltage dip. The results of hybrid scheme are compared with STFCL only and are found better for the former case. MATLAB/Simulink is used for simulation of 9 MW wind turbine interfaced with grid.
In this paper, a model reference controller (MRC) based on a neural network (NN) is proposed for damping oscillations in electric power systems. Variation in reactive load, internal or external perturbation/faults, and asynchronization of the connected machine cause oscillations in power systems. If the oscillation is not damped properly, it will lead to a complete collapse of the power system. An MRC base unified power flow controller (UPFC) is proposed to mitigate the oscillations in 2-area, 4-machine interconnected power systems. The MRC controller is using the NN for training, as well as for plant identification. The proposed NN-based MRC controller is capable of damping power oscillations; hence, the system acquires a stable condition. The response of the proposed MRC is compared with the traditionally used proportional integral (PI) controller to validate its performance. The key performance indicator integral square error (ISE) and integral absolute error (IAE) of both controllers is calculated for single phase, two phase, and three phase faults. MATLAB/Simulink is used to implement and simulate the 2-area, 4-machine power system.