Purpose: Quantitative volumetricT1mapping in the liver has the potential to aid in the detection, diagnosis, and quantification of liver fibrosis, inflammation, and spatially resolved liver function. However, accurate measurement of hepaticT1is confounded by the presence of fat and inhomogeneous excitation. Furthermore, scan time constraints related to respiratory motion require tradeoffs of reduced volumetric coverage and/or increased acquisition time. This work presents a novel 3D acquisition and estimation method for confounder‐correctedT1measurement over the entire liver within a single breath‐hold through simultaneous estimation ofT1, fat and .Theory and Methods: The proposed method combines chemical shift encoded MRI and variable flip angle MRI with a mapping technique to enable confounder‐correctedT1mapping. The method was evaluated theoretically and demonstrated in both phantom and in vivo acquisitions at 1.5 and 3.0T. At 1.5T, the method was evaluated both pre‐ and post‐ contrast enhancement in healthy volunteers.Results: The proposed method demonstrated excellent linear agreement with reference inversion‐recovery spin‐echo basedT1in phantom acquisitions at both 1.5 and 3.0T, with minimal bias (5.2 and 45 ms, respectively) overT1ranging from 200–1200 ms. In vivo results were in general agreement with reference saturation‐recovery based 2DT1maps (SMART1Map, GE Healthcare).Conclusion: The proposed 3DT1mapping method accounts for fat and confounders through simultaneous estimation ofT1, , PDFF and . It demonstrates strong linear agreement with referenceT1measurements, with low bias and high precision, and can achieve full liver coverage in a single breath‐hold.
Purpose: Quantitative T1 mapping has the potential to replace biopsy for noninvasive diagnosis and quantitative staging of chronic liver disease. Conventional T1 mapping methods are confounded by fat and inhomogeneities, resulting in unreliable T1 estimations. Furthermore, these methods trade off spatial resolution and volumetric coverage for shorter acquisitions with only a few images obtained within a breath‐hold. This work proposes a novel, volumetric (3D), free‐breathing T1 mapping method to account for multiple confounding factors in a single acquisition.Theory and Methods: Free‐breathing, confounder‐corrected T1 mapping was achieved through the combination of non‐Cartesian imaging, magnetization preparation, chemical shift encoding, and a variable flip angle acquisition. A subspace‐constrained, locally low‐rank image reconstruction algorithm was employed for image reconstruction. The accuracy of the proposed method was evaluated through numerical simulations and phantom experiments with a T1/proton density fat fraction phantom at 3.0 T. Further, the feasibility of the proposed method was investigated through contrast‐enhanced imaging in healthy volunteers, also at 3.0 T.Results: The method showed excellent agreement with reference measurements in phantoms across a wide range of T1 values (200 to 1000 ms, slope = 0.998 (95% confidence interval (CI) [0.963 to 1.035]), intercept = 27.1 ms (95% CI [0.4 54.6]), r2 = 0.996), and a high level of repeatability. In vivo imaging studies demonstrated moderate agreement (slope = 1.099 (95% CI [1.067 to 1.132]), intercept = −96.3 ms (95% CI [−82.1 to −110.5]), r2 = 0.981) compared to saturation recovery‐based T1 maps.Conclusion: The proposed method produces whole‐liver, confounder‐corrected T1 maps through simultaneous estimation of T1, proton density fat fraction, and in a single, free‐breathing acquisition and has excellent agreement with reference measurements in phantoms.