Armin Werber

Armin Werber

Auto-generated profile, based on publicly available information

Armin Werber

Laboratory for Micro-optics, Institute of Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 102, 79110 Freiburg, Germany

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2005 in Applied Optics
Verified
Journal Article
Closed access
PDF file
AWArmin Werber
Armin Werber
HZHans Zappe
Hans Zappe
A novel type of liquid microlens, bounded by a microfabricated, distensible membrane and activated by a microfluidic liquid-handling system, is presented. By use of an elastomer membrane fabricated by spin coating onto a dry-etched silicon substrate, the liquid-filled cavity acts as a lens whereby applied pressure changes the membrane distension and thus the focal length. Both plano–convex and plano–concave lenses, individual elements as well as arrays, were fabricated and tested. The lens surface roughness was seen to be ∼9 nm rms, and the focal length could be tuned from 1 to 18 mm. This lens represents a robust, self-contained tunable optical structure suitable for use in, for example, a medical environment.

1 January 2007
Verified
Conference Paper
Closed access
JFJens Fiala
Jens Fiala
SRStephan Reichelt
Stephan Reichelt
AWArmin Werber
Armin Werber
PBPhilipp Bingger
Philipp Bingger
HZHans Zappe
Hans Zappe
FBFriedhelm Beyersdorf
Friedhelm Beyersdorf
A miniaturized photoplethysmographic sensor system which utilizes the principle of pulse oximetry is presented. The sensor is designed to be implantable and will permit continuous monitoring of important human vital parameters such as arterial blood oxygen saturation as well as pulse rate and shape over a long-term period in vivo. The system employs light emitting diodes and a photo transistor embedded in a transparent elastic cuff which is directly wrapped around an arterial vessel. This paper highlights the specific challenges in design, instrumentation, and electronics associated with that sensor location. In vitro measurements were performed using an artificial circulation system which allows for regulation of the oxygen saturation and pulsatile pumping of whole blood through a section of a domestic pig's arterial vessel. We discuss our experimental results compared to reference CO-oximeter measurements and determine the empirical calibration curve. These results demonstrate the capabilities of the pulse oximeter implant for measurement of a wide range of oxygen saturation levels and pave the way for a continuous and mobile monitoring of high-risk cardiovascular patients.