Zahra Nasiri-Gheidari

Zahra Nasiri-Gheidari

Auto-generated profile, based on publicly available information

Zahra Nasiri-Gheidari

Electrical Engineering Department, Sharif University of Technology, Tehran, Iran

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RARamin Alipour-Sarabi
Ramin Alipour-Sarabi
ZNZahra Nasiri-Gheidari
Zahra Nasiri-Gheidari
HOHashem Oraee
Hashem Oraee
Numerical and analytical methods are two methods to evaluate the performance of electrical machines. This paper provides a comparison between numerical and analytical methods. Electrical machine software typically use numerical methods to solve the electromagnetic equations. On the other hand, analytical methods are faster and more intuitive. A general analytical modeling technique to evaluate the performance of axial flux machines including but not limited to wound rotor resolvers is presented here. The proposed model is based on the actual three dimensional magnetic equivalent circuit (3-D MEC). The accuracy of the proposed model depends on the number of radial layers in the reluctance network of the machine and the time step of simulation. Flux fringing effect, skewed slots, static and dynamic eccentricity, and core magnetization curve are included in the model. Excitation method of the resolver determines the input(s) and output(s) of the algorithm. Both current and voltage excitations are discussed in the paper. Finally, the results of the proposed 3-D MEC model under healthy and eccentric (static and dynamic) rotor conditions are compared with the finite element analysis (FEA) in terms of computation time and accuracy. The results confirm high accuracy-high speed performance of the 3-D MEC model.

8 March 2018 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
ADAhmad Daniar
Ahmad Daniar
ZNZahra Nasiri-Gheidari
Zahra Nasiri-Gheidari
FTFarid Tootoonchian
Farid Tootoonchian
Linear Variable Reluctance (LVR) resolvers have substantial benefits that make them suitable for linear motion control drives. The optimal design of LVR resolvers needs an accurate modelling that is usually achieved by three-dimensional (3-D) time stepping finite element method (TSFEM). However, 3-D TSFEM is very time consuming method and is unsuitable for co-usage with optimization algorithms. So, in this paper an accurate analytical model based on improved winding function (IWF) method is proposed. The proposed model is used to calculate the inductances, air-gap flux density, induced voltages and linear position error. The distinguished feature of the proposed model is direct usage of the turn function in calculating the inductances. While, the conventional modified winding function (MWF) method uses the Fourier Seri of the turn function. So, the proposed model is much faster and more accurate than the models based on conventional MWF method. The results of the proposed model are verified with those of 3-D TSFEM. Then, the proposed model is used for design optimization of the sensor. Also, two methods are proposed for compensating the longitudinal end effect. Finally, the experimental prototype is used to evaluate the developed analytical model and the optimization process.

16 September 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MBM. Bahari
M. Bahari
ADA. Davoodi
A. Davoodi
HSH. Saneie
H. Saneie
FTF. Tootoonchian
F. Tootoonchian
ZNZ. Nasiri-Gheidari
Z. Nasiri-Gheidari
Resolvers as position sensors need a high frequency AC excitation voltage, and the induced voltage in their 2-phase perpendicular windings are amplitude modulated (AM) signals. For calculating the position, it is required to demodulated the output signals and calculate their envelopes. Then, inverse tangent can be used for calculating the position. Despite the advantages of resolvers, there are some drawbacks in their application. Calculating the envelopes is always one of the deep concerns in using resolvers. Furthermore, due to low-amplitude of the excitation flux, the performance of the resolvers is strongly affected by electromagnetic interference by the stray fields of motor and brake. Complicated winding process is the next challenge of resolvers. The last concern is referred to the high speed applications where to maintain the accuracy of the sensor it is required to increase the excitation frequency. While, the maximum frequency of excitation is limited by the frequency response of the employed ferromagnetic core and the employed resolver to digital converter (RDC). To overcome all the mentioned worries, a new permanent magnet (PM) resolver is proposed in this paper. The presented resolver has no copper winding and no need to the high frequency excitation. It is equipped by low-price Hall Effect sensors to measure the magnetic flux density and has a robust performance in high electromagnetic disturbance environments. All the analysis is done using time stepping finite element method (TSFEM) and verified by experimental measurements on a built prototype.

31 May 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RARamin Alipour-Sarabi
Ramin Alipour-Sarabi
ZNZahra Nasiri-Gheidari
Zahra Nasiri-Gheidari
FTFarid Tootoonchian
Farid Tootoonchian
HOHashem Oraee
Hashem Oraee
Among position sensors, resolvers are superior from reliability point of view. However, obtaining lower output voltage harmonics and simple manufacturing process is a challenge in the design and optimization of resolvers. In this paper, a metaheuristic optimization algorithm is used to minimize total harmonic distortion of the output signals, and consequently the estimated position error in concentrated coil wound field resolvers. Meanwhile, to minimize total coil numbers, manufacturing costs, and complexity of the winding process, modified objective function and constraints are proposed. In this way, a modified winding function method is employed for performance analysis of the axial flux resolver. Then, the merits of the optimized winding configuration with respect to fractional slot concentrated windings are shown. The results of the proposed configurations are verified with a three-dimensional time-stepping finite-element method. Finally, the prototype of the studied axial flux resolver is constructed and tested. Good agreement is obtained between simulation and experimental results, confirming the effectiveness of the optimization process.

10 October 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RARamin Alipour-Sarabi
Ramin Alipour-Sarabi
ZNZahra Nasiri-Gheidari
Zahra Nasiri-Gheidari
FTFarid Tootoonchian
Farid Tootoonchian
HOHashem Oraee
Hashem Oraee
High pole number permanent magnet (PM) motors, due to their high torque density, have been receiving considerable attentions in recent years. To achieve an accurate position control in PM machines, resolvers are suggested for industrial applications. Mechanical and electromagnetic considerations in the case of high pole number resolvers lead the machine designers to choose small cores with low slot numbers. This paper proposes two different on-tooth winding configurations to achieve high pole number without increasing the slot numbers, while the accuracy of the detected position is intended to be the maximum value. Variable turn on tooth winding (VTTW) is compared with fractional slot concentrated winding (FSCW) for two-phase machines. By the aid of winding function's harmonic contents and winding factors, the accuracy of different configurations is analyzed and confirmed by the 3-D time stepping finite-element method. Results show that the wound field resolver equipped with FSCW has higher accuracy than the VTTW. Moreover, it is shown that concentrated winding suffers from sub-harmonics. In this regard, a modification on the rotor winding is performed to decrease the total harmonic distortion of output signals and decrease the estimated position error. In addition, the role of winding layers and displacement angle between them is further investigated in this paper. Finally, a prototype with 20-pole 6-layer FSCW resolver has been constructed. Practical results are in good agreement with the analytical predictions.

29 January 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HSHamid Saneie
Hamid Saneie
ZNZahra Nasiri-Gheidari
Zahra Nasiri-Gheidari
Single-phase, outer-rotor squirrel cage induction motors are widely used in ceiling fan applications. Furthermore, they can be employed for pumps, and in-wheel hub drives. In this paper an analytical model based on magnetic equivalent circuit (MEC) is proposed to evaluate the performance of the motor. The influence of rotor slots’ skewing, stator end windings, slots’ leakage inductance, and core saturation are included in the model. Furthermore, the windings’ copper losses and the core's iron losses are calculated using the proposed model. The results of the presented model are compared with those of time variant finite element analysis (TVFEA) and experimental measurements. Close agreement between the results confirms the success of the proposed model from accuracy point of view. Furthermore, the computation time required for the proposed model considering the linear and non-linear cores are one minute, and 11 minutes, respectively. However those of TVFEA considering 64000 mesh elements for linear and non-linear cores are 21, and 28 hours, respectively.