19 March 2024 in Mechanism and Machine Theory
25 December 2023 in IEEE Robotics and Automation Letters
Force feedback is of importance in Minimally Invasive Surgery (MIS) as it reduces surgical risks and enhances surgical safety. However, equipping force sensing to the tip of surgical instruments presents challenges due to their diminutive dimensions and often curved shapes. To address this issue, a novel and compact optical-based 3-Axial force sensor used for the surgical forceps is proposed. Based on the extent of disruption to the total internal reflection (TIR), the magnitude and the direction of the force can be detected by measuring the light intensity patterns from three intersecting channels. The calibration experiments validate the capability of the proposed sensor to accurately measure forces within the range of 0 to 3 N, achieving an average measurement error of 0.089N. Subsequently, the sensor, along with the detection circuit, are integrated onto a surgical forcep, and verification experiments are conducted. The results indicate that the proposed sensor can provide effective 3-Axial force sensing during the surgical process such as grasping, manipulation, and pulling. The characteristics of compact size, high precision, and integrability of the sensor make it highly promising for providing force feedback in MIS.
9 April 2025 in IEEE/ASME Transactions on Mechatronics
Elastomer-based soft manipulators have been explored in various fields due to their inherent compliant properties. Understanding and regulation of robot's compliance are important to the design, modeling, and control of soft robots. However, the elastomers are nonlinear hyperelastic materials with distributed compliance. This property makes the compliance modeling and control of soft robots fundamentally different and more complex from their rigid counterparts. This article presents a neo-Hookean model-based compliance modeling and control approach to investigate and regulate the configuration-dependent compliance property of a pneumatic-driven soft manipulator. The neo-Hookean model is used to derive the stretch ratio and update the tangent modulus of materials. The robot's compliance is obtained by integration with the forward kinematics building on the static Cosserat rod model. The derived compliance matrix is utilized to regulate robot's compliance along the $x$-, $y$-, and $z$-axes. Computational and experimental validation demonstrate high fidelity of the proposed approach. Moreover, experiments illustrate that the exhibited robot's compliance can be regulated up to 49.5% higher or 34.2% lower compared to inherent robot's compliance. The proposed model-based compliance control strategy has also demonstrated its effectiveness in enhancing grasping ability when implemented on a soft gripper.
28 October 2025 in IEEE Transactions on Robotics
Elastomer-based soft manipulators with fibre-reinforced chambers, represent a prevalent design paradigm in soft robotics. These robots incorporate multiple actuation chambers, enabling elongation and bending motions. However, the inherent compliance of materials and the pressurised chambers inevitably introduce significant nonlinearity to these robots. Moreover, design of such robots often relies on a trial-and-error approach. Consequently, a comprehensive robot prototyping framework is of paramount importance. To achieve this, we present a static modelling, design and evaluation framework for soft robots with densely reinforced chambers (i.e., the angle between the reinforcement fibre and the axial direction of soft robots is 90°). We first propose a static analytical modelling framework to achieve both the forward kinematics and the tip force generation modelling. This modelling framework accommodates the effects of pressurised chambers and (non)linear material behaviours. Furthermore, our design and evaluation framework incorporates an open-accessible simulation toolbox with a user-friendly graphical interface, along with a physical evaluation platform. The entire framework is validated by eight kinds of manipulators with varying diameters and lengths. Meanwhile, the nonlinearity introduced by geometrical deformation resulting from the elongation, the pressurised actuation chambers (i.e., the chamber stiffening effect), and material hyper-elasticity are investigated. Results also enable informed decision-making on design specifications prior to robot fabrication.
26 May 2025 in IEEE Transactions on Medical Robotics and Bionics
Manual hand-held catheterization by clinicians under Magnetic Resonance Imaging (MRI) has become popular for the treatment of cardiovascular diseases such as pulmonary edema and heart failure. However, the limited space of the MRI bore makes it challenging for clinicians to access the opening, and the prolonged operation can cause back injury. To implement MRI-guided robot-assisted catheterization, this paper presents an MR-conditional robotic system for right heart catheterization (MR-RHC). Our 2-degree-of-freedom (DoF) robotic manipulator is actuated by ultrasonic piezoelectric motors. The highly compact design (D× W× L=11 cm× 8 cm× 18 cm) allows the robot to be positioned in the MRI scanner bore, near the patient’s femoral vein opening. The contribution of this paper lies in the development of an MR-conditional robotic system that clinically required Swan-Ganz catheter movements, including (simultaneous) infinite continuous rotation and translation (i.e., the catheter can perform endless rotation and translation that are not restricted by cable tangling or limited operational motion of the actuators). The MR conditionality of the robotic system is demonstrated in a clinical MR environment. Additionally, the system has been characterized in terms of its force and torque capabilities and verified 100% success rate of tele-intervention within 7 patient specific phantoms. Lastly, the paper reports the intervention of an MRI-guided robot-operated catheter within the water-filled phantoms between the control room and MR scanner.
19 January 2026 in IEEE Robotics & Automation Magazine
Right heart catheterization (RHC) is a critical procedure for diagnosing and managing cardiovascular diseases (CVDs) such as heart failure, congenital heart disease, pulmonary edema, and pulmonary hypertension. However, currently prevalent manual RHC procedures require continuous communication of clinicians between the main control room and the operating room, leading to navigation inaccuracies and increased physical workload for clinicians during prolonged procedures. To overcome these challenges, this article introduces a robotic system that enables autonomous RHC (Auto-RHC) by transferring a catheter decision-making model from patient-specific (PS) digital twins to real-world robotic intervention using deep learning (DL) algorithms. By creating a PS digital twin using the Simulation Open Framework Architecture (SOFA) and conducting virtual RHC interventions, images capturing the catheter balloon’s position and aligned behavioral datasets were collected and utilized as input for a convolutional neural network (CNN) architecture. The trained catheter decision-making model derived from the digital twin was then transferred to real-world implementations of robot-assisted Auto-RHC. Experimental results validated the performance of the digital twin and demonstrated that the real-world robotic Auto-RHC achieved a high success rate across both static (≥96%) and dynamic heartbeat (≥94%) PS cardiac phantoms. Furthermore, Auto-RHC enhanced navigation consistency by ≥34.63% compared to expert manual operation.