Brenden A. Butters

Brenden A. Butters

Auto-generated profile, based on publicly available information

Brenden A. Butters

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2023 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
ICI. Charaev
I. Charaev
DBD. A. Bandurin
D. A. Bandurin
ABAnthony Bollinger
Anthony Bollinger
IPI. Y. Phinney
I. Y. Phinney
IDI. Drozdov
I. Drozdov
KBK. K. Berggren
K. K. Berggren

6 November 2020 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
RBReza Baghdadi
Reza Baghdadi
JAJason P. Allmaras
Jason P. Allmaras
BBBrenden A. Butters
Brenden A. Butters
ADAndrew E. Dane
Andrew E. Dane
SISaleem Iqbal
Saleem Iqbal
KBKarl K. Berggren
Karl K. Berggren
We demonstrate a multilayer nanoscale cryogenic heater-based switch (M-hTron) that uses a normal-metal heater overlapping a thin-film superconductor separated by a thin insulating layer. The M-hTron eliminates leakage current found in three-terminal superconducting switches and applies heat locally to the superconductor, reducing the energy required to switch the device. Modeling using the energy-balance equations and the acoustic mismatch model demonstrates reasonable agreement with experiment. The M-hTron is a promising device for digital superconducting electronics that require high fan-out and offers the possibility of enhancing readout for superconducting-nanowire single-photon detectors.

25 January 2021 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
BBBrenden A Butters
Brenden A Butters
RBReza Baghdadi
Reza Baghdadi
MOMurat Onen
Murat Onen
ETEmily A Toomey
Emily A Toomey
OMOwen Anthony Medeiros
Owen Anthony Medeiros
KBKarl K Berggren
Karl K Berggren
There has been a demand for a scalable superconducting memory technology for cryogenic computing for some time. This demand has proven difficult to satisfy due to the simultaneous need for high speed operation, low power consumption, and high density, all while maintaining cryogenic and SFQ compatibility. In an effort to satisfy this demand, we have developed a simple memory cell based on our prior work with nanowire-based memories. Due to the memory cell’s reliance on kinetic inductance, the cell can be scaled to almost any size. The cell has been designed specifically such that it can easily form into an array simply by arranging in a 2D pattern. This design eliminated the need for external addressing circuitry. This new cell, when operated in isolation and without the heater, performs very well with predicted bit error rates around 10 −17 . However, preliminary array tests show that while the memory operates, the predicted error rates rise to 1.5 × 10 −3 . We believe that this issue is predominantly due to the hTron-channel kinetic inductance dramatically changing upon the application of the row-select heaters. This issue might be addressed by designing the cell to compensate for the change in kinetic inductance when the heater is activated. If this remedy proves to be effective, then this memory would enable the development of compact and scalable memory arrays.

6 January 2026 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
OMOwen Medeiros
Owen Medeiros
MCMatteo Castellani
Matteo Castellani
VKValentin Karam
Valentin Karam
RFReed Foster
Reed Foster
ASAlejandro Simon
Alejandro Simon
KBKarl K. Berggren
Karl K. Berggren

31 March 2022 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
BBBrenden Butters
Brenden Butters
AFAlvaro Fernandez-Galiana
Alvaro Fernandez-Galiana
DWDaniel Wollin
Daniel Wollin
GTGiovanni Traverso
Giovanni Traverso
Alexander SlocumAlexander Slocum
Alexander Slocum
JPJohn Petrozza
John Petrozza
The fixation and manipulation of fibroids during laparoscopic myomectomy is a persistent issue for gynecologic surgeons. In this paper, we present a laparoscopic grasper that, through a sheath-based deployment mechanism, opens into a larger multitoothed grasper within the patient and collapses back for removal. Due to the increased number of contact points with the tumor, the expanded grasper allows for reliable fixation, aiding in manipulation during excision. We describe the nature-inspired design of the grasper from a physical foundation, establish the design theory and practical issues, and present manufacturing and testing of a full-scale 5 mm grasper. The unit was tested on synthetic fibroid models and was able to sustain a 50% higher load before tearing than a common single-tooth tenaculum. This development not only promises to improve fibroid fixation in myomectomy but also its design could be adapted to aid in the fixation of other difficult tissues in laparoscopic surgery.