Nina Strandkjær

Nina Strandkjær

Auto-generated profile, based on publicly available information

Nina Strandkjær

Department of Cardiology, Herlev Hospital, University Hospital of Copenhagen , Herlev

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2021 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Closed access
PDF file
NSNina Strandkjær
Nina Strandkjær
MHMalene Kongsgaard Hansen
Malene Kongsgaard Hansen
SNSofie Taageby Nielsen
Sofie Taageby Nielsen
RFRuth Frikke-Schmidt
Ruth Frikke-Schmidt
ATAnne Tybjærg-Hansen
Anne Tybjærg-Hansen
PKPia R Kamstrup
Pia R Kamstrup
Background and Objective High lipoprotein(a) is a genetically determined causal risk factor for cardiovascular disease, and 20% of the adult population has high levels (ie, >42 mg/dL, >88 nmol/L). We investigated whether early life lipoprotein(a) levels measured in cord blood may serve as a proxy for neonatal venous blood levels, whether lipoprotein(a) birth levels (ie, cord or venous) predict levels later in life, and whether early life and parental levels correlate. Methods The Compare study is a prospective cohort study of newborns (N = 450) from Copenhagen, Denmark, including blood sampling of parents. Plasma lipoprotein(a) was measured in cord blood (N = 402), neonatal venous blood (N = 356), and at 2 (N = 320) and 15 months follow-up (N = 148) of infants, and in parents (N = 705). Results Mean lipoprotein(a) levels were 2.2 (95% CI, 1.9-2.5), 2.4 (2.0-2.7), 4.1 (3.4-4.9), and 14.6 (11.4-17.9) mg/dL in cord, neonatal venous, and 2- and 15-month venous samples, respectively. Lipoprotein(a) levels in cord blood correlated strongly with neonatal venous blood levels (R2 = 0.95, P < 0.001) and neonatal levels correlated moderately with 2- and 15-month levels (R2 = 0.68 and 0.67, both P < 0.001). Birth levels ≥ 90th percentile predicted lipoprotein(a) > 42 mg/dL at 15 months with positive predictive values of 89% and 85% for neonatal venous and cord blood. Neonatal and infant levels correlated weakly with parental levels, most pronounced at 15 months (R2 = 0.22, P < 0.001). Conclusions Lipoprotein(a) levels are low in early life, cord blood may serve as a proxy for neonatal venous blood, and birth levels ≥ 90th percentile can identify newborns at risk of developing high levels.

8 October 2024 in Circulation
Verified
Journal Article
Open access
JKJonas Henrik Kristensen
Jonas Henrik Kristensen
RHRasmus Bo Hasselbalch
Rasmus Bo Hasselbalch
NSNina Strandkjær
Nina Strandkjær
NJNicoline Jørgensen
Nicoline Jørgensen
MØMorten Østergaard
Morten Østergaard
KIKasper Karmark Iversen
Kasper Karmark Iversen
BACKGROUND: Cardiac troponin (cTn) is key in diagnosing myocardial infarction (MI). After MI, the clinically observed half-life of cTn has been reported to be 7 to 20 hours, but this estimate reflects the combined elimination and simultaneous release of cTn from cardiomyocytes. More precise timing of myocardial injuries necessitates separation of these 2 components. We used a novel method for determination of isolated cTn elimination kinetics in humans. METHODS: Patients with MI were included within 24 hours after revascularization and underwent plasmapheresis to obtain plasma with a high cTn concentration. After at least 3 weeks, patients returned for an autologous plasma retransfusion followed by blood sampling for 8 hours. cTn was measured with 5 different high-sensitivity cTn assays. RESULTS: Of 25 included patients, 20 participants (mean age, 64.5 years; SD, 8.2 years; 4 women [20%]) received a retransfusion after a median of 5.8 weeks (interquartile range, 5.0–6.9 weeks) after MI. After retransfusion of a median of 620 mL (range, 180–679 mL) autologous plasma, the concentration of cTn in participants’ blood increased 4 to 445 times above the upper reference level of the 5 high-sensitivity cTn assays. The median elimination half-life ranged from 134.1 minutes (95% CI, 117.8–168.0) for the Elecsys high-sensitivity cTnT assay to 239.7 minutes (95% CI, 153.7–295.1) for the Vitros high-sensitivity cTnI assay. The median clearance of cTnI ranged from 40.3 mL/min (95% CI, 32.0–44.9) to 52.7 mL/min (95% CI, 42.2–57.8). The clearance of cTnT was 77.0 mL/min (95% CI, 45.2–95.0). CONCLUSIONS: This novel method showed that the elimination half-life of cTnI and cTnT was 5 to 16 hours shorter than previously reported. This indicates a considerably longer duration of cardiomyocyte cTn release after MI than previously thought. Improved knowledge of timing of myocardial injury may call for changes in the management of MI and other disorders with myocardial injury.

15 July 2025 in Clinical Chemistry
Verified
Journal Article
Open access
SSSelma M Salonen
Selma M Salonen
JKJonas H Kristensen
Jonas H Kristensen
SSSara Simonen
Sara Simonen
RHRasmus Bo Hasselbalch
Rasmus Bo Hasselbalch
NSNina Strandkjær
Nina Strandkjær
SWSaara Wittfooth
Saara Wittfooth
Background: High-sensitivity cardiac troponin (hs-cTn) assays are prone to negative and positive interferences caused by endogenous cardiac troponin-specific autoantibodies (cTnAAbs). Large macrotroponin complexes formed of cardiac troponin (cTn) and cTnAAbs may result in falsely elevated hs-cTn results. This is potentially due to reduced clearance of macrotroponin, but direct evidence is still lacking. In this study, we investigated the possible effects of cTnAAbs on the elimination of cTn. Methods: Twenty patients with ST-elevation myocardial infarction (MI) underwent plasmapheresis within 24 h after revascularization to harvest plasma with a high cTn concentration. After clinical recovery, patients returned to the hospital for autologous plasma re-transfusion. Following re-transfusion, blood samples were collected at fixed time points and analyzed with 5 commercial hs-cTn assays. The presence of cTnAAbs in the samples and the epitope specificity of cTnAAbs were investigated with in-house immunoassays. Results: Altogether, 2 out of 20 patients (10%) were cTnAAb-positive. With 4 commercial hs-cTn assays, cTnAAb-positive patients mainly showed longer elimination half-lives and slower cTn clearances than most cTnAAb-negative patients. One hs-cTn assay was prone to negative cTnAAb interference but correspondingly less prone to positive macrotroponin interference. The central part of cardiac troponin I (cTnI) was predominantly affected by cTnAAbs. Conclusions: Endogenous cTnAAbs were for the first time shown to prolong the elimination half-life and reduce the clearance of cTn in the circulation. Additionally, the extent of analytical interference from cTnAAbs and their reactivity to macrotroponin varies among commercial hs-cTn assays, an important consideration for laboratories to ensure accurate diagnosis of MI.

10 June 2025 in Clinical Chemistry
Verified
Journal Article
Closed access
NSNina Strandkjær
Nina Strandkjær
MHMorten Bagge Hansen
Morten Bagge Hansen
SAShoaib Afzal
Shoaib Afzal
RHRasmus Bo Hasselbalch
Rasmus Bo Hasselbalch
SKSophie Sander Knudsen
Sophie Sander Knudsen
OHOla Hammarsten
Ola Hammarsten
Background: Cardiac troponin (cTn) levels exceeding the 99th percentile upper reference limit and a rise/fall pattern are key for diagnosing myocardial injury and infarction. Macrotroponins, formed by patient anti-cTn antibodies targeting cTn, can cause persistently elevated cTn levels without ongoing myocardial injury. The frequency and impact of macrotroponin interference on cTn 99th percentiles are unclear. This study compares sex-specific 99th percentiles for 2 cTn assays, before and after excluding macrotroponin-positive samples, focusing on the top 10% of cTn levels. Methods: We examined 1058 plasma samples from healthy individuals previously used for Danish cTn 99th percentiles. Following International Federation of Clinical Chemistry and Laboratory Medicine educational recommendations, macrotroponin presence was assessed in the top 10% cTn samples using immunoglobulin G (IgG) depletion screening and a reference sucrose gradient, confirming macrotroponin when both methods concurred. Due to analytical dilution constraints, [the highest] 88 of 135 Siemens Atellica high-sensitivity cTnI (hs-cTnI) samples were analyzed with both methods. All 106 Roche hs-cTnT samples were negative using IgG depletion, and sucrose analysis was limited to the highest 70 samples. Results: Macrotroponin was found in 76% (67/88) of Siemens samples but in none of the Roche samples (0/70). Excluding macrotroponin-affected samples lowered the Siemens 99th percentiles from 117 ng/L to 22 ng/L in men and from 37 ng/L to 9 ng/L in women. The 99th/50th percentile ratio for Siemens decreased from 12- to 29-fold to 3- to 7-fold, approaching the Roche ratios. Conclusions: Macrotroponin significantly influenced the Siemens Atellica hs-cTnI 99th percentiles, suggesting important clinical implications that warrant further prospective studies. The 99th/50th percentile ratio may help evaluate macrotroponin interference in troponin assays.

7 May 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
NSNina Strandkjær
Nina Strandkjær
NJNicoline Jørgensen
Nicoline Jørgensen
RHRasmus Bo Hasselbalch
Rasmus Bo Hasselbalch
JKJonas Kristensen
Jonas Kristensen
MKMarie Sophie Sander Knudsen
Marie Sophie Sander Knudsen
KIKasper Karmark Iversen
Kasper Karmark Iversen
Background: Cardiac troponins are the preferred biomarkers for the diagnosis of acute myocardial infarction. Although sex‐specific 99th percentile thresholds of troponins are recommended in international guidelines, the clinical effect of their use is poorly investigated. The DANSPOT Study (The Danish Study of Sex‐ and Population‐Specific 99th percentile upper reference limits of Troponin) aims to evaluate the clinical effect of a prospective implementation of population‐ and sex‐specific diagnostic thresholds of troponins into clinical practice. Methods: This study is a nationwide, multicenter, stepped‐wedge cluster‐randomized trial of the implementation of population‐ and sex‐specific thresholds of troponins in 22 of 23 clinical centers in Denmark. We established sex‐specific thresholds for 5 different troponin assays based on troponin levels in a healthy Danish reference population. Centers will sequentially cross over from current uniform manufacturer‐derived thresholds to the new population‐ and sex‐specific thresholds. The primary cohort is defined as patients with symptoms suggestive of acute coronary syndrome having at least 1 troponin measurement performed within 24 hours of arrival with a peak troponin value between the current uniform threshold and the new sex‐specific female and male thresholds. The study will compare the occurrence of the primary outcome, defined as a composite of nonfatal myocardial infarction, unplanned revascularization, and all‐cause mortality within 1 year, separately for men and women before and after the implementation of the new sex‐specific thresholds. Conclusions: The DANSPOT Study is expected to show the clinical effects on diagnostics, treatment, and clinical outcomes in patients with myocardial infarction of implementing sex‐specific diagnostic thresholds for troponin based on a national Danish reference population. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05336435.

28 April 2026 in European Heart Journal
Verified
Journal Article
Closed access
AKAlexander Holst Kronborg
Alexander Holst Kronborg
RHRasmus Bo Hasselbalch
Rasmus Bo Hasselbalch
CPCasper Holm Grund Pedersen
Casper Holm Grund Pedersen
SKSophie Sander Knudsen
Sophie Sander Knudsen
HBHenning Bundgaard
Henning Bundgaard
NSNina Strandkjær
Nina Strandkjær