23 August 2024 in International Journal of Emergency Medicine
Introduction: Mass casualty incidents (MCI) are unforeseeable and complex events that occur worldwide, therefore enhancing the training that medical first responders (MFRs) receive is fundamental to strengthening disaster preparedness and response. In recent years, extended reality (XR) technology has been introduced as a new approach and promising teaching technique for disaster medicine education. Objective: To assess the effectiveness of XR simulation as a tool to train MFRs in MCIs, and to explore the perception and experience of participants to these new forms of training. Design: Systematic review. Methods: This systematic review was conducted in accordance with the “Preferred reporting items for systematic reviews and meta-analyses” (PRISMA) statement. Four databases were searched (MEDLINE, EMBASE, CINAHL and LILACs) using a comprehensive search strategy to identify relevant articles, and MetaQAT was used as a study quality assessment tool. Data from included studies was not pooled for meta-analysis due to heterogeneity. Extracted data was synthesised in a narrative, semi-quantitative manner. Results: A total of 18 studies were included from 8 different countries. Studies encompassed a variety of participants (e.g., nurses, paramedics, physicians), interventions (virtual, mixed and augmented reality), comparators (comparison between two groups and single groups with pre-post evaluation), and outcomes (effectiveness and MFR perception). The synthesis of data indicated that XR was an effective tool for prehospital MCI training by means of improved triage accuracy, triage time, treatment accuracy, performance correctness and/or knowledge acquired. These XR systems were well perceived by MFRs, who expressed their interest and satisfaction towards this learning experience and emphasized its usefulness and relevance. Conclusion: This research supports the usefulness and significance of XR technology that allows users to enhance their skills and confidence when facing forthcoming disasters. The findings summarize recommendations and suggestions for the implementation, upgrade and/or assessment of this novel and valuable teaching method.
23 March 2023 in PLOS ONE
Introduction/Background: Mass-casualty incidents (MCIs) and disasters require an organised and effective response from medical first responders (MFRs). As such, novel training methods have emerged to prepare and adequately train MFRs for these challenging situations. Particular focus should be placed on extended reality (XR), which encompasses virtual, augmented and mixed reality (VR, AR, and MR, respectively), and allows participants to develop high-quality skills in realistic and immersive environments. Given the rapid evolution of high-fidelity simulation technology and its advantages, XR simulation has become a promising tool for emergency medicine. Accordingly, this systematic review aims to: 1) evaluate the effectiveness of XR training methods and 2) explore the experience of MFRs undergoing such training.Methods: A comprehensive search strategy will encompass four distinct themes: MFRs, disasters/MCIs, education and simulation, and XR. Four databases (MEDLINE, EMBASE, CINAHL and LILACs) will be searched along with an in-depth examination of the grey literature and reference lists of relevant articles. MetaQAT will be used as a study quality assessment tool and integrated into Covidence as part of the data extraction form. Given the predicted high heterogeneity between studies, it may not be possible to standardise data for quantitative comparison and meta-analysis. Thus, data will be synthesised in a narrative, semi-quantitative manner.Discussion: This review will examine the existing literature on the effectiveness of XR simulation as a tool to train MFRs for MCIs, which could ultimately improve preparedness and response to disasters.Trial registration: Protocol registration:PROSPEROCRD42021275692.
18 June 2024 in BMC Health Services Research
Introduction: Medical First Responders (MFRs) in the emergency department SUMMA 112 are tasked with handling the initial management of Mass Casualty Incidents (MCI) and building response capabilities. Training plays a crucial role in preparing these responders for effective disaster management. Yet, evaluating the impact of such training poses challenges since true competency can only be proven amid a major event. As a substitute gauge for training effectiveness, self-efficacy has been suggested.Objective: The purpose of this study is to employ a pre- and post-test assessment of changes in perceived self-efficacy among MFRs following an intervention focused on the initial management of MCI. It also aimed to evaluate a self-efficacy instrument for its validity and reliability in this type of training.Method: In this study, we used a pretest (time 1 = T1) – post-test (time 2 = T2) design to evaluate how self-efficacy changed after a training intervention with 201 MFRs in initial MCI management. ANOVA within-subjects and between subjects analyses were used.Results: The findings reveal a noteworthy change in self-efficacy before and after training among the 201 participants. This suggests that the training intervention positively affected participants’ perceived capabilities to handle complex situations like MCI.Conclusion: The results allow us to recommend a training program with theory components together with practical workshops and live, large-scale simulation exercises for the training of medical first responders in MCI, as it significantly increases their perception of the level of self-efficacy for developing competencies associated with disaster response.
11 February 2022 in Journal of Emergency Nursing
MGMaría Eugenia Gómez-Robledo
María Eugenia Gómez-Robledo
Standard precautions, including protections from blood and body fluid exposure, are designed to protect health care providers from infections. Sharps safety practices rarely include the potential for the unconscious patient's own body to be a potential source of clinician percutaneous injury from sharp objects outside of the perioperative setting. This case report reviews a percutaneous injury to the hand of a physician who was performing chest compressions on a patient with an out-of-hospital cardiac arrest. The 76-year-old patient in cardiac arrest had undergone a medial sternotomy surgery 15 years before the arrest. The sternal wire rotated owing to the initial chest compressions, breaking the clinician's nitrile glove and producing an open wound on the thenar region of the clinician's right hand. Application of a 10 × 10 12-ply gauze pack on the chest of the patient in cardiac arrest allowed the resuscitation team to continue with the compressions with no further wounds from the wire. This case report is a novel contribution to the published literature and advances standard precautions considerations in patients with out-of-hospital cardiac arrest, with the sternotomy wire from previous surgery as a source of percutaneous clinician injury during chest compression.
1 February 2026 in BMC Medical Education
Background: Virtual Reality (VR) generates an artificial environment in which users interact with computer-generated scenarios and sounds. Using devices such as headsets and motion sensors, users are immersed in a simulated world. Augmented reality (AR) is an interactive overlay of the real environment that provides an additional wrapper over the environment, and the user experiences an immersive and interactive environment. In Mixed reality (MR), VR and AR elements are combined; computer graphics interplay with real objects, allowing users to interact with virtual and physical objects at the same time. VR and MR are effective training tools in different healthcare settings. These tools are useful for preparing emergency health personnel to respond to disasters by providing them with an immersive reality since real practices are very difficult to implement in mass casualty incidents. Given the usefulness of this approach, assessing the optimal training times associated with this method and the side effects that may influence learning is helpful. One of the most common side effects is fatigue. We developed a questionnaire to assess fatigue in terms of various dimensions, that can affect a person while training in the context of VR and MR. Methods: We designed a questionnaire to assess the fatigue levels perceived by professionals and validated this measure after VR training experience. We analyzed ratings of visual, mental, physical, and general fatigue. This questionnaire was applied to emergency professionals (Sample size = 101). Results: The reliability and validity of the questionnaire were assessed in terms of the following factors: general, social, emotional, visual, and motivational fatigue. Conclusions: The results of this research suggest that fatigue is an element of VR and MR training. Educators should take these effects into account to optimize learning in the context of VR and MR. According to user feedback, the optimal length of time for mixed reality training is around 20 min, especially when the user has little or no experience.
1 July 2026 in Advances in Simulation
SESalvador Espinosa-Ramírez
Salvador Espinosa-Ramírez
Introduction: Throughout Europe, Emergency Medical Services (EMS) rely heavily on Medical First Responders (MFR) to ensure early stabilization and appropriate handling of complex Mass Casualty Incidents (MCI). Mixed Reality (MR), also known as Augmented Reality (AR), provides interactive training by integrating real environments with digital components. This technology enables MFR to practise complex decision-making and hands-on interventions in high-stress, simulated scenarios. However, assessing its genuine effectiveness remains challenging, as true competency is often difficult to demonstrate outside real-life emergencies. This study aims to measure pre- and post-test changes in perceived self-efficacy among MFR following a targeted MR intervention focused specifically on the initial management of MCI. Method: A pre-test/post-test survey design was employed with 274 MFR who underwent detailed MR training simulating complex, early-stage MCI scenarios. To analyze the intervention’s precise impact on participant confidence, data were analyzed using both within- and between-subjects ANOVA, providing information about the change in self-efficacy across the cohort. Results: The analysis revealed a statistically significant increase in perceived self-efficacy among the 274 participants following the training (F(1,270)=169.36, p< .01, η 2 =.385). The mean score increased from 34.45 (SD=6.27) to 38.38 (SD=5.40), representing an absolute increase of 3.93 points. This corresponds to an 11.41% increase relative to baseline scores and an 8.19% increase when calculated against the maximum possible score (48 points), indicating a strong practical effect of the intervention. The MR intervention could detect change and indicate a positive influence on confidence and how a combined approach including MR training can improve MFR perceived preparedness. Conclusion: Findings suggest that MR training significantly enhances MFRs' perceived self-efficacy in managing MCIs. Consequently, integrating immersive MR technologies into emergency training programs may represent a valuable complementary strategy for strengthening organizational disaster preparedness and improving MFR confidence and decision-making skills in high-stakes situations.