Andrea Pergolini

Andrea Pergolini

Auto-generated profile, based on publicly available information

Andrea Pergolini

The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
APAndrea Pergolini
Andrea Pergolini
CLChiara Livolsi
Chiara Livolsi
ETEmilio Trigili
Emilio Trigili
BCBaojun Chen
Baojun Chen
FGFrancesco Giovacchini
Francesco Giovacchini
NVNicola Vitiello
Nicola Vitiello
Powered hip exoskeletons, in combination with passive prostheses, have been recently proposed to improve the economy and pattern of walking of lower-limb amputees within clinical scenarios. However, for everyday life support, a real-time control strategy that can accurately recognize different locomotion modes and transitions is required. In this letter, we proposed a novel locomotion recognition algorithm for an Active Pelvis Orthosis designed to assist people with lower-limb amputation, in quasi-static (sit-to-stand/stand-to-sit) and dynamic locomotion modes (walking and stairs negotiation). Two finite-state machines were combined to recognize in real-time the participants’ locomotion, one was a rule-based algorithm and one was based on four linear discriminant analysis classifiers. Four transfemoral amputees took part in the experiments and performed a circuit of tasks in two conditions, namely in transparent mode (the exoskeleton was controlled to provide null output impedance), and in assistive mode (the exoskeleton was controlled to output an assistive torque consistently with the locomotion mode recognized by the algorithm), to test the algorithm in real-time conditions. The median (25 th , 75 th percentile) between-subjects recognition accuracy was 94.8% (93.4%, 96.5%) with user-dependent models. Offline analysis on user-independent models with leave-one-subject-out validation resulted in between-subjects recognition accuracy equal to 95.9% (94.0%, 97.8%). The results of this study pave the way for future experimentations of the technology in ecological scenarios.

25 March 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
APAndrea Pergolini
Andrea Pergolini
TBThomas Bowman
Thomas Bowman
TLTiziana Lencioni
Tiziana Lencioni
AMAlberto Marzegan
Alberto Marzegan
MMMario Meloni
Mario Meloni
SCSimona Crea
Simona Crea
Individuals with Parkinson’s disease (PD) are characterized by gait and balance disorders limiting their independence and quality of life. Home-based rehabilitation programs, combined with drug therapy, demonstrated to be beneficial in the daily-life activities of PD subjects. Sensorized shoes can extract balance- and gait-related data in home-based scenarios and allow clinicians to monitor subjects’ activities. In this study, we verified the capability of a pair of sensorized shoes (including pressure-sensitive insoles and one inertial measurement unit) in assessing ground-level walking and body weight shift exercises. The shoes can potentially be combined with a sensory biofeedback module that provides vibrotactile cues to individuals. Sensorized shoes have been assessed in terms of the capability of detecting relevant gait events (heel strike, flat foot, toe off), estimating spatiotemporal parameters of gait (stance, swing, and double support duration, stride length), estimating gait variables (vertical ground-reaction force, vGRF; coordinate of the center of pressure along the longitudinal axes of the feet, yCoP; and the dorsiflexion angle of the feet, Pitch angle). The assessment compared the outcomes with those extracted from the gold standard equipment, namely force platforms and a motion capture system. Results of this comparison with 9 PD subjects showed an overall median absolute error lower than 0.03 s in detecting the foot-contact, foot-off, and heel-off gait events while performing ground-level walking and lower than 0.15 s in body weight shift exercises. The computation of spatiotemporal parameters of gait showed median errors of 1.62 % of the stance phase duration and 0.002 m of the step length. Regarding the estimation of vGRF, yCoP, and Pitch angle, the median across-subjects Pearson correlation coefficient was 0.90, 0.94, and 0.91, respectively. These results confirm the suitability of the sensorized shoes for quantifying biomechanical features during body weight shift and gait exercises of PD and pave the way to exploit the biofeedback modules of the bidirectional interface in future studies.

9 July 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
CLChiara Livolsi
Chiara Livolsi
CSC. B. Sanz-Morère
C. B. Sanz-Morère
APA. Pergolini
A. Pergolini
AGA. Giffone
A. Giffone
FGF. Giovacchini
F. Giovacchini
NVNicola Vitiello
Nicola Vitiello
Transfemoral amputation is a debilitating condition that leads to long-term mobility restriction and secondary disorders that negatively affect the quality of life of millions of individuals worldwide. Currently available prostheses are not able to restore energetically efficient and functional gait, thus, recently, the alternative strategy to inject energy at the residual hip has been proposed to compensate for the lack of energy of the missing leg. Here, we show that a portable and powered hip exoskeleton assisting both the residual and intact limb induced a reduction of walking energy expenditure in four individuals with above-knee amputation. The reduction of the energy expenditure, quantified using the Physiological Cost Index, was in the range [-10, -17] % for all study participants compared to walking without assistance, and between [-2, -24] % in three out of four study participants compared to walking without the device. Additionally, all study participants were able to walk comfortably and confidently with the hip exoskeleton overground at both their self-selected comfortable and fast speed without any observable alterations in gait stability. The study findings confirm that injecting energy at the hip level is a promising approach for individuals with above-knee amputation. By reducing the energy expenditure of walking and facilitating gait, a hip exoskeleton may extend mobility and improve locomotor training of individuals with above-knee amputation, with several positive implications for their quality of life.

16 September 2025 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
APAndrea Pergolini
Andrea Pergolini
CSClara Beatriz Sanz-Morere
Clara Beatriz Sanz-Morere
CLChiara Livolsi
Chiara Livolsi
MFMatteo Fantozzi
Matteo Fantozzi
FDFilippo Dell’aGnello
Filippo Dell’aGnello
NVNicola Vitiello
Nicola Vitiello
Most individuals who experience a stroke exhibit several sensorimotor impairments that limit their independence in everyday activities. Hemiparetic gait is frequently characterized by reduced knee flexion in swing due to knee stiffness or muscle weakness and knee hyperextension or knee buckling in the stance phase. Recently, unilateral-powered orthoses have been designed to overcome the limitations of the passive knee-ankle-foot orthoses. This study presents a unilateral Active Knee Orthosis Exoskeleton, AKO-$\beta$, endowed with a series elastic actuator and designed to assist the knee in flexion and extension movements. The paper describes the system mechatronic design and its characterization on the bench, the control system, and pilot experiments with three post-stroke participants. The device has a weight of 1.78 kg on the user's leg, with a lateral encumbrance of 76 mm. The pilot experiments aimed to verify the effects of the exoskeleton assistance in hemiparetic gait patterns. When walking with the device, participants on average increased the knee flexion on the paretic side by 18.70 deg (+44.9%) during swing and decreased knee hyperextension in stance by 4.50 deg, compared to walking without it. Overall, when walking with the exoskeleton, subjects showed improved Gait Variable Score of the paretic knee profile by 37.5% compared to walking without it. The temporal and spatial gait symmetry indexes did not show clear changes, although an improvement in symmetry was observed in two of the three participants. These preliminary results suggest the potential benefits of the unilateral Active Knee Orthosis exoskeleton to enhance and restore mobility in individuals with hemiparetic gait.