The pathophysiological mechanisms underlying severe cardiac dysfunction after aneurysmal subarachnoid haemorrhage (aSAH) remain poorly understood. In the present study, we focused on two categories of contributing factors describing the brain–heart relationship. The first group includes brain-specific cerebrospinal fluid (CSF) and serum biomarkers, as well as cardiac-specific biomarkers. The secondary category encompasses parameters associated with cerebral autoregulation and the autonomic nervous system. A group of 15 aSAH patients were included in the analysis. Severe cardiac complications were diagnosed in seven (47%) of patients. In the whole population, a significant correlation was observed between CSF S100 calcium-binding protein B (S100B) and brain natriuretic peptide (BNP) (rS = 0.62; p = 0.040). Additionally, we identified a significant correlation between CSF neuron-specific enolase (NSE) with cardiac troponin I (rS = 0.57; p = 0.025) and BNP (rS = 0.66; p = 0.029), as well as between CSF tau protein and BNP (rS = 0.78; p = 0.039). Patients experiencing severe cardiac complications exhibited notably higher levels of serum tau protein at day 1 (0.21 ± 0.23 [ng/mL]) compared to those without severe cardiac complications (0.03 ± 0.04 [ng/mL]); p = 0.009. Impaired cerebral autoregulation was noted in patients both with and without severe cardiac complications. Elevated serum NSE at day 1 was related to impaired cerebral autoregulation (rS = 0.90; p = 0.037). On the first day, a substantial, reciprocal correlation between heart rate variability low-to-high frequency ratio (HRV LF/HF) and both GFAP (rS = −0.83; p = 0.004) and S100B (rS = −0.83; p = 0.004) was observed. Cardiac and brain-specific biomarkers hold the potential to assist clinicians in providing timely insights into cardiac complications, and therefore they contribute to the prognosis of outcomes.
Considering the variety of complications that arise after aneurysmal subarachnoid haemorrhage (aSAH) and the complex pathomechanism of delayed cerebral ischaemia (DCI), the task of predicting the outcome assumes a profound complexity. Therefore, there is a need to develop early predictive and decision-making models. This study explores the effect of serum biomarkers and clinical scales on patients’ outcomes and their interrelationship with DCI and systemic complications in aSAH. This was a retrospective analysis including aSAH patients admitted to the Wroclaw University Hospital (Wrocław, Poland) from 2011 to 2020. A good outcome was defined as a modified Rankin Scale (mRS) score of 0–2. The prediction of the development of DCI and poor outcome was conducted using logistic regression as a standard model (SM) and random forest as a machine learning method (ML). A cohort of 174 aSAH patients were included in the analysis. DCI was diagnosed in 79 (45%) patients. Significant differences between patients with poor vs. good outcome were determined from their levels of albumin (31 ± 7 vs. 35 ± 5 (g/L); p < 0.001), D-dimer (3.0 ± 4.5 vs. 1.5 ± 2.8 (ng/mL); p < 0.001), procalcitonin (0.2 ± 0.4 vs. 0.1 ± 0.1 (ng/mL); p < 0.001), and glucose (169 ± 69 vs. 137 ± 48 (nmol/L); p < 0.001). SM for DCI prediction included the Apache II scale (odds ratio [OD] 1.05; 95% confidence interval [CI] 1.00–1.09) and albumin level (OD 0.88; CI 0.82–0.95). ML demonstrated that low albumin level, high Apache II scale, increased D-dimer and procalcitonin levels had the highest predictive values for DCI. The integration of clinical parameters and scales with a panel of biomarkers may effectively facilitate the stratification of aSAH patients, identifying those at high risk of secondary complications and poor outcome.
23 February 2022 in Applied Bionics and Biomechanics
The aim of this experimental study was to analyze the impact of applying different configurations of the transpedicular fixation system on selected mechanical parameters of the thoracolumbar spine under conditions of its instability (after simulated fracture). Five study groups were tested: physiological, with compression fracture of the vertebra, with two-segment fixation, with three-segment fixation, and with four-segment fixation. Each of the analyzed study groups was subjected to axial compression, flexion, and extension. Based on the conducted experimental tests, the mechanical parameters, i.e., stiffness coefficient and dissipation energy, were determined for all groups under consideration. The stiffness value of two-segment fixation is significantly lower than the physiological value (during flexion and extension). The use of long-segment fixation considered in two configurations (three- and four-segment fixation) may result in excessive stiffness of the system due to the high stiffness values achieved (approx. 2530 higher than the physiological values in the case of compression and on average 60 higher in the case of flexion). The use of long-segment fixator design shows better results than short-segment fixation. Considering both biomechanical and clinical aspects, three-segment fixation seems to be a compromise solution as it saves the patient from more extensive stiffening of the spinal motion segments.
Contemporary clinical practice is progressively shifting towards percutaneous minimally invasive surgery. Conversely, the incorporation of transverse connectors in the design of spinal fixation systems is associated with more invasive open surgical procedures. The primary objective of this investigation was to evaluate the influence of transverse connectors in posterior spinal fixation system designs in cases involving vertebral compression fractures, specifically on selected mechanical parameters of the thoracolumbar spine in situations of instability. This research objective was achieved through a combination of experimental tests and numerical simulations. From the experimental tests conducted, critical mechanical parameters were ascertained, including the bending stiffness coefficient and energy dissipation. Numerical simulations were employed to determine additional parameters, such as the angular range of motion for individual spinal segments, intradiscal pressure within individual intervertebral discs, and stress distribution on the articular facets. Analyzing the impact of transverse connectors on the obtained results revealed that their inclusion in a fixation system results in a minor increase in stiffness and a decrease in mobility in comparison to fixation systems devoid of connectors. These findings create the potential for utilizing minimally invasive surgery as a viable alternative to open surgical procedures.