Piezoelectric polymers characterized by flexibility are sought for applications in microelectronics, medicine, telecommunications, and everyday devices. The objective of this work was to obtain piezoelectric polymeric composites with a cellular structure and to evaluate their usefulness in practice. Composites based on polyolefins (isotactic-polypropylene and polyethylene) with the addition of aluminosilicate fillers were manufactured by extrusion, and then polarized in a constant electric field at 100 V/µm. The content of mineral fillers up to 10 wt% in the polymer matrix enhances its electric stability and mechanical strength. The value of the piezoelectric coefficient d33 attained ~150 pC/N in the range of lower stresses and ~80 pC/N in the range of higher stresses, i.e., at ~120 kPa. The materials exhibited high durability in time, therefore, they can be used as transducers of mechanical energy of the human motion into electric energy. It was demonstrated that one shoe insert generates an energy of 1.1 mJ after a person walks for 300 s. The miniaturized integrated circuits based on polyolefin composites may be applied for the power supply of portable electronics. Due to their high sensitivity, they can be recommended for measuring the blood pulse.
Static and dynamic methods can be used to assess the way a foot is loaded. The research question is how the pressure on the feet would vary depending on walking/running speed. This study involved 20 healthy volunteers. Dynamic measurement of foot pressure was performed using the Ortopiezometr at normal, slow, and fast paces of walking. Obtained data underwent analysis in a “Steps” program. Based on the median, the power generated by the sensors during the entire stride period is the highest during a fast walk, whereas based on the average; a walk or slow walk prevails. During a fast walk, the difference between the mean and the median of the stride period is the smallest. Regardless of the pace of gait, the energy released per unit time does not depend on the paces of the volunteers’ gaits. Conclusions: Ortopiezometr is a feasible tool for the dynamic measurement of foot pressure. For investigations on walking motions, the plantar pressure analysis system, which uses the power generated on sensors installed in the insoles of shoes, is an alternative to force or energy measurements. Regardless of the pace of the walk, the amounts of pressure applied to the foot during step are similar among healthy volunteers.
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.