Repeatable and reliable site-specific preparation of specimens for atom probe tomography (APT) at cryogenic temperatures has proven challenging. A generalized workflow is required for cryogenic specimen preparation including lift-out via focused ion beam and in situ deposition of capping layers, to strengthen specimens that will be exposed to high electric field and stresses during field evaporation in APT and protect them from environment during transfer into the atom probe. Here, we build on existing protocols and showcase preparation and analysis of a variety of metals, oxides, and supported frozen liquids and battery materials. We demonstrate reliable in situ deposition of a metallic capping layer that significantly improves the atom probe data quality for challenging material systems, particularly battery cathode materials which are subjected to delithiation during the atom probe analysis itself. Our workflow design is versatile and transferable widely to other instruments.
As hydrogen is touted as a key player in the decarbonization of modern society, it is critical to enable quantitative hydrogen (H) analysis at high spatial resolution and, if possible, at the atomic scale. H has a known deleterious impact on the mechanical properties (strength, ductility, toughness) of most materials that can hinder their use as part of the infrastructure of a hydrogen-based economy. Enabling H mapping including local hydrogen concentration analyses at specific microstructural features is essential for understanding the multiple ways that H affect the properties of materials including embrittlement mechanisms and their synergies. In addition, spatial mapping and quantification of hydrogen isotopes is essential to accurately predict tritium inventory of future fusion power plants thus ensuring their safe and efficient operation. Atom probe tomography (APT) has the intrinsic capability to detect H and deuterium (D), and in principle the capacity for performing quantitative mapping of H within a material's microstructure. Yet, the accuracy and precision of H analysis by APT remain affected by complex field evaporation behavior and the influence of residual hydrogen from the ultrahigh vacuum chamber that can obscure the signal of H from within the material. The present article reports a summary of discussions at a focused workshop held at the Max-Planck Institute for Sustainable Materials in April 2024. The workshop was organized to pave the way to establishing best practices in reporting APT data for the analysis of H. We first summarize the key aspects of the intricacies of H analysis by APT and then propose a path for better reporting of the relevant data to support interpretation of APT-based H analysis in materials.
Atom probe tomography requires needle-shaped specimens with a diameter typically below 100 nm, making them both very fragile and reactive, and defects (notches at grain boundaries or precipitates) are known to affect the yield and data quality. The use of a conformal coating directly on the sharpened specimen has been proposed to increase yield and reduce background. However, to date, these coatings have been applied ex situ and mostly are not uniform. Here, we report on the controlled focused-ion beam in situ deposition of a thin metal film on specimens immediately after specimen preparation. Different metallic targets e.g. Cr were attached to a micromanipulator via a conventional lift-out method and sputtered using Ga or Xe ions. We showcase the many advantages of coating specimens from metallic to nonmetallic materials. We have identified an increase in data quality and yield, an improvement of the mass resolution, as well as an increase in the effective field-of-view. This wider field-of-view enables visualization of the entire original specimen, allowing to detect the complete surface oxide layer around the specimen. The ease of implementation of the approach makes it very attractive for generalizing its use across a very wide range of atom probe analyses.
The early stages of corrosion occurring at liquid‐solid interfaces control the evolution of the material's degradation process, yet due to their transient state, their analysis remains a formidable challenge. Here corrosion tests are performed on a MgCa alloy, a candidate material for biodegradable implants using pure water as a model system. The corrosion reaction is suspended by plunge freezing into liquid nitrogen. The evolution of the early‐stage corrosion process on the nanoscale by correlating cryo‐atom probe tomography (APT) with transmission‐electron microscopy (TEM) and spectroscopy, is studied. The outward growth of Mg hydroxide Mg(OH)2 and the inward growth of an intermediate corrosion layer consisting of hydrloxides of different compositions, mostly monohydroxide Mg(OH) instead of the expected MgO layer, are observed. In addition, Ca partitions to these newly formed hydroxides and oxides. Density‐functional theory calculations suggest a domain of stability for this previously experimental unreported Mg(OH) phase. This new approach and these new findings advance the understanding of the early stages of magnesium corrosion, and in general reactions and processes at liquid‐solid interfaces, which can further facilitate the development of corrosion‐resistant materials or better control of the biodegradation rate of future implants.
Atom probe tomography (APT) has been established in the microscopic chemical and spatial analysis of metallic or semiconductors nanostructures. In recent years, and especially with the development of a transfer shuttle system and adapted preparation protocols, the field of frozen liquids has been opened up. Still, very limited knowledge is available about the evaporation and fragmentation behavior of frozen liquids in APT. In this work, efforts were made to extend the method toward organic and biological soft matter, which are mostly built from hydrocarbon chains, the evaporation and fragmentation behavior of simple alkane chains (n-tetradecanes). Tetradecane shows a very complex evaporation behavior whereby peaks of C1–C15 can be observed. Based on multihit events and the representation of these in correlation plots, more detailed information about the evaporation behavior and the decay of molecules into smaller fragments in the region near the tip can be studied. A variety of different dissociation tracks of larger molecules in their excited state and their subsequent decay in low-field regions, on the way to the detector, could be observed and the dissociation zone in the low-field region was calculated.