Luc Duempelmann

Luc Duempelmann

Auto-generated profile, based on publicly available information

Luc Duempelmann

ICFO-Institut de Ciencies Fotoniques, The Barcelona Institute of Science and Technology, Av. Carl Friedrich Gauss, 3, 08860 Castelldefels, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2015 in ACS Photonics
Verified
Journal Article
Closed access
LDLuc Duempelmann
Luc Duempelmann
ALAngélique Luu-Dinh
Angélique Luu-Dinh
BGBenjamin Gallinet
Benjamin Gallinet
LNLukas Novotny
Lukas Novotny

22 September 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
LGLukas Greuter
Lukas Greuter
SSSebastian Starosielec
Sebastian Starosielec
DNDaniel Najer
Daniel Najer
ALArne Ludwig
Arne Ludwig
LDLuc Duempelmann
Luc Duempelmann
RWRichard J. Warburton
Richard J. Warburton
We report the realization of a spatially and spectrally tunable air-gap Fabry-Pérot type microcavity of high finesse and cubic-wavelength-scale mode volume. These properties are attractive in the fields of opto-mechanics, quantum sensing, and foremost cavity quantum electrodynamics. The major design feature is a miniaturized concave mirror with atomically smooth surface and radius of curvature as low as 10 μm produced by CO2 laser ablation of fused silica. We demonstrate excellent mode-matching of a focussed laser beam to the microcavity mode and confirm from the frequencies of the resonator modes that the effective optical radius matches the physical radius. With these small radii, we demonstrate wavelength-size beam waists. We also show that the microcavity is sufficiently rigid for practical applications: in a cryostat at 4 K, the root-mean-square microcavity length fluctuations are below 5 pm.

2 November 2015 in ACS Nano
Verified
Journal Article
Closed access
LDLuc Duempelmann
Luc Duempelmann
DCDaniele Casari
Daniele Casari
ALAngélique Luu-Dinh
Angélique Luu-Dinh
BGBenjamin Gallinet
Benjamin Gallinet
LNLukas Novotny
Lukas Novotny

1 October 2019 in Analytica Chimica Acta
Verified
Journal Article
Open access
NFNuria Fabri-Faja
Nuria Fabri-Faja
OCOlalla Calvo-Lozano
Olalla Calvo-Lozano
Priyanka DeyPriyanka Dey
Priyanka Dey
RTRoland A. Terborg
Roland A. Terborg
M.-Carmen EstevezM.-Carmen Estevez
M.-Carmen Estevez
LLLaura M. Lechuga
Laura M. Lechuga
Sepsis is a condition characterized by a severe stage of blood-infection often leading to tissue damage, organ failure and finally death. Fast diagnosis and identification of the sepsis stage (sepsis, severe sepsis or septic shock) is critical for the patient's evolution and could help in defining the most adequate treatment in order to reduce its mortality. The combined detection of several biomarkers in a timely, specific and simultaneous way could ensure a more accurate diagnosis. We have designed a new optical point-of-care (POC) device based on a phase-sensitive interferometric biosensor with a label-free microarray configuration for potential high-throughput evaluation of specific sepsis biomarkers. The sensor chip, which relies on the use of metallic nanostructures, provides versatility in terms of biofunctionalization, allowing the efficient immobilization of different kind of receptors such as antibodies or oligonucleotides. We have focused on two structurally different types of biomarkers: proteins, including C-reactive protein (CRP) and Interleukin 6 (IL6), and miRNAs, using miRNA-16 as an example. Limits of Detection (LoD) of 18 μg mL-1, 88 μg mL-1 and 1 μM (6 μg mL-1) have been respectively obtained for CRP, IL6 and miRNA-16 in individual assays, with high accuracy and reproducibility. The multiplexing capabilities have also been assessed with the simultaneous analysis of both protein biomarkers.

19 November 2021 in Science Advances
Verified
Journal Article
Open access
RCRobin Camphausen
Robin Camphausen
ÁSÁlvaro Andrés Cuevas Seguel
Álvaro Andrés Cuevas Seguel
LDLuc Duempelmann
Luc Duempelmann
RTRoland A. Terborg
Roland A. Terborg
EWEwelina Wajs
Ewelina Wajs
VPValerio Pruneri
Valerio Pruneri
Hyperentanglement and SPAD array camera enable wide-field supersensitive quantum imaging.

1 August 2013 in Analytical Chemistry
Verified
Journal Article
Open access
BBBenjamin Bircher
Benjamin Bircher
LDLuc Duempelmann
Luc Duempelmann
KRKasper Renggli
Kasper Renggli
HLHans Peter Lang
Hans Peter Lang
CGChristoph Gerber
Christoph Gerber
TBThomas Braun
Thomas Braun
A microcantilever based method for fluid viscosity and mass density measurements with high temporal resolution and microliter sample consumption is presented. Nanomechanical cantilever vibration is driven by photothermal excitation and detected by an optical beam deflection system using two laser beams of different wavelengths. The theoretical framework relating cantilever response to the viscosity and mass density of the surrounding fluid was extended to consider higher flexural modes vibrating at high Reynolds numbers. The performance of the developed sensor and extended theory was validated over a viscosity range of 1–20 mPa·s and a corresponding mass density range of 998–1176 kg/m3 using reference fluids. Separating sample plugs from the carrier fluid by a two-phase configuration in combination with a microfluidic flow cell, allowed samples of 5 μL to be sequentially measured under continuous flow, opening the method to fast and reliable screening applications. To demonstrate the study of dynamic processes, the viscosity and mass density changes occurring during the free radical polymerization of acrylamide were monitored and compared to published data. Shear-thinning was observed in the viscosity data at higher flexural modes, which vibrate at elevated frequencies. Rheokinetic models allowed the monomer-to-polymer conversion to be tracked in spite of the shear-thinning behavior, and could be applied to study the kinetics of unknown processes.