29 August 2024 in IEEE Transactions on Instrumentation and Measurement
The efficient perception of the underwater flow field is of great significance to the development of underwater intelligent equipment. Driven by unique whisker receptors of the harbor seals, this study proposes and demonstrates a bio-inspired whisker sensor based on orthometric Fiber Bragg Grating (BIWS-OFBG). Four FBGs are deployed around an artificial whisker as basic sensing units. The hydrodynamic information is encoded as the wavelength evolution of the FBGs. In the underwater experiment, BIWS-OFBG obtains the vortex street distribution in the bionic fishtail wake. It realizes frequency locking with RMSE of 0.0208 Hz and rotation direction recognition of the vortex with a maximum detection distance of 300 mm. Oscillatory stimulus are also detectable. Based on the theoretical model, we further give the calibrated function to express the relationship between wavelength shift and steady flow velocity. A maximum sensitivity of 0.86 nm/(m/s) is achieved. The suggested device provides a new framework for the design of bionic whisker sensors. Replacing integrated circuits with optical fiber sensing units will greatly enhance the adaptability of sensors in extreme application scenarios.
11 March 2025 in IEEE Sensors Journal
We built a reflective parallel tapered optical fiber structure and used it as a biosensor for highly sensitive in situ detection of label-free Mucin 1 (MUC1). A sensing tapered optical fiber probe was prepared, and a reference probe of similar Free Spectral Range (FSR) was connected in parallel to establish the optical Vernier-effect. This arrangement amplified the refractive index (RI) sensitivity to 8.4 times that of a single sensing probe with 19845.22 nm/RIU. Meanwhile, the aptamer was chemically bonded to the surface of sensing probe to specifically detect MUC1. This biosensor has a linear wide detection range of 10-10 - 10-1 mg/mL, with a high sensitivity of 12.56 nm/log(C/C0) and a low limit of detection (LOD) of 0.012 pg/mL. Significantly, the reflective structures, unlike transmissive ones, could be inserted into samples rather than requiring samples to be moved to the sensing area, which not only reduces contamination of samples during movement, but also enables the measurement of trace samples that cannot be transferred. Further, this novel sensing structure with high sensitivity holds promise for the preliminary diagnosis and prognostic monitoring of cancer and has broad development prospects in clinical and therapeutic applications.