18 February 2011 in Acta Ophthalmologica
4 March 2013 in Ophthalmic and Physiological Optics
7 August 2007 in Epilepsia
1 November 2010 in Investigative Ophthalmology & Visual Science
Purpose.: To establish an alternative method, sequential and diameter response analysis (SDRA), to determine dynamic retinal vessel responses and their time course in serial stimulation compared with the established method of averaged diameter responses and standard static assessment. Methods.: SDRA focuses on individual time and diameter responses, taking into account the fluctuation in baseline diameter, providing improved insight into reaction patterns when compared with established methods as delivered by retinal vessel analyzer (RVA) software. SDRA patterns were developed with measurements from 78 healthy nonsmokers and subsequently validated in a group of 21 otherwise healthy smokers. Fundus photography and retinal vessel responses were assessed by RVA, intraocular pressure by contact tonometry, and blood pressure by sphygmomanometry. Results.: Compared with the RVA software method, SDRA demonstrated a marked difference in retinal vessel responses to flickering light (P < 0.05). As a validation of that finding, SDRA showed a strong relation between baseline retinal vessel diameter and subsequent dilatory response in both healthy subjects and smokers (P = 0.001). The RVA software was unable to detect this difference or to find a difference in retinal vessel arteriovenous ratio between smokers and nonsmokers (P = 0.243). However, SDRA revealed that smokers' vessels showed both an increased level of arterial baseline diameter fluctuation before flicker stimulation (P = 0.005) and an increased stiffness of retinal arterioles (P = 0.035) compared with those in nonsmokers. These differences were unrelated to intraocular pressure or systemic blood pressure. Conclusions.: SDRA shows promise as a tool for the assessment of vessel physiology. Further studies are needed to explore its application in patients with vascular diseases.
1 August 2011 in Investigative Ophthalmology & Visual Science
Purpose.: Cardiac function, such as heart rate variability, is abnormal in coronary artery disease, but its relation with the function of ocular and nail-fold blood vessels is unknown. The hypothesis was that there is abnormal retinal and peripheral microvascular endothelial function compared with large blood vessel and cardiac function. Twenty-four patients with coronary artery disease (CAD) and 30 healthy, age- and sex-matched control subjects were enrolled in the study. Methods.: Peripheral microcirculatory function was measured with continuous retinal vessel diameter assessment and nail-fold capillaroscopy. Systemic vascular function was evaluated by 24-hour blood pressure, arterial stiffness, low (LF)- and high (HF)-frequency heart rate variability, ECG monitoring, and the plasma markers von Willebrand factor (vWf) and soluble E selectin. Results.: Peripheral nail-fold capillary (P = 0.009) and retinal vessel (average baseline corrected flicker response [BFR]; P = 0.034) responses and reaction time in response to flicker (P = 0.016) were significantly different in patients compared with controls. Furthermore, patients demonstrated higher arterial stiffness (P = 0.005), LF and HF heart rate variability (P = 0.004, P = 0.006), and vWf level (P = 0.044), but there was no difference in soluble E selectin level (P = 0.278). In the CAD patients, LF and HF heart rate variability both correlated with average BFR (r = 0.58, P = 0.004; r = −0.6, P = 0.003, respectively). There was no such relationship in the healthy controls. Conclusions.: Microcirculatory abnormalities of the retina and nail-fold vessels are present in CAD. The two indices of heart rate variability correlated with an index of ocular vessel responses. The latter may be a surrogate marker of abnormal heart rate variability in CAD.