Robert Peter Cubbidge

Robert Peter Cubbidge

Auto-generated profile, based on publicly available information

Robert Peter Cubbidge

School of Life and Health Sciences, Aston University, Birmingham, UK

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HBHetal D Buckhurst
Hetal D Buckhurst
BGBernard Gilmartin
Bernard Gilmartin
RCRobert P Cubbidge
Robert P Cubbidge
NLNicola S Logan
Nicola S Logan
Anterior segment optical coherent tomography (AS-OCT, Visante; Zeiss) is used to examine meridional variation in anterior scleral thickness (AST) and its association with refractive error, ethnicity and gender. Scleral cross-sections of 74 individuals (28 males; 46 females; aged between 18-40 years (27.7±5.3)) were sampled twice in random order in 8 meridians: [superior (S), inferior (I), nasal (N), temporal (T), superior-temporal (ST), superior-nasal (SN), inferior-temporal (IT) and inferior-nasal (IN)]. AST was measured in 1mm anterior-to-posterior increments (designated the A-P distance) from the scleral spur (SS) over a 6mm distance. Axial length and refractive error were measured with a Zeiss IOLMaster biometer and an open-view binocular Shin-Nippon autorefractor. Intra- and inter-observer variability of AST was assessed for each of the 8 meridians. Mixed repeated measures ANOVAs tested meridional and A-P distance differences in AST with refractive error, gender and ethnicity. Only right eye data were analysed. AST (mean±SD) across all meridians and A-P distances was 725±46μm. Meridian SN was the thinnest (662±57μm) and I the thickest (806±60μm). Significant differences were found between all meridians (p<0.001), except S:ST, IT:IN, IT:N and IN:N. Significant differences between A-P distances were found except between SS and 6 mm and between 2 and 4 mm. AST measurements at 1mm (682±48 μm) were the thinnest and at 6mm (818±49 μm) the thickest (p<0.001); a significant interaction occurred between meridians and A-P distances (p<0.001). AST was significantly greater (p<0.001) in male subjects but no significant differences were found between refractive error or ethnicity. Significant variations in AST occur with regard to meridian and distance from the SS and may have utility in selecting optimum sites for pharmaceutical or surgical intervention.

18 February 2011 in Acta Ophthalmologica
Verified
Journal Article
Closed access
PDF file
JAJennifer Acton
Jennifer Acton
RCRobert P. Cubbidge
Robert P. Cubbidge
HKHelen King
Helen King
PGPaul Galsworthy
Paul Galsworthy
JGJonathan M. Gibson
Jonathan M. Gibson

4 March 2013 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
HBHetal Buckhurst
Hetal Buckhurst
BGBernard Gilmartin
Bernard Gilmartin
RCRobert P Cubbidge
Robert P Cubbidge
MNManbir Nagra
Manbir Nagra
NLNicola S Logan
Nicola S Logan

7 August 2007 in Epilepsia
Verified
Journal Article
Closed access
PDF file
MCMiriam Conway
Miriam Conway
RCRobert P. Cubbidge
Robert P. Cubbidge
SHSarah L. Hosking
Sarah L. Hosking

1 November 2010 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
RHRebekka Heitmar
Rebekka Heitmar
ABAndrew D. Blann
Andrew D. Blann
RCRobert P. Cubbidge
Robert P. Cubbidge
GLGregory Y. H. Lip
Gregory Y. H. Lip
Doina GherghelDoina Gherghel
Doina Gherghel
Purpose.: To establish an alternative method, sequential and diameter response analysis (SDRA), to determine dynamic retinal vessel responses and their time course in serial stimulation compared with the established method of averaged diameter responses and standard static assessment. Methods.: SDRA focuses on individual time and diameter responses, taking into account the fluctuation in baseline diameter, providing improved insight into reaction patterns when compared with established methods as delivered by retinal vessel analyzer (RVA) software. SDRA patterns were developed with measurements from 78 healthy nonsmokers and subsequently validated in a group of 21 otherwise healthy smokers. Fundus photography and retinal vessel responses were assessed by RVA, intraocular pressure by contact tonometry, and blood pressure by sphygmomanometry. Results.: Compared with the RVA software method, SDRA demonstrated a marked difference in retinal vessel responses to flickering light (P < 0.05). As a validation of that finding, SDRA showed a strong relation between baseline retinal vessel diameter and subsequent dilatory response in both healthy subjects and smokers (P = 0.001). The RVA software was unable to detect this difference or to find a difference in retinal vessel arteriovenous ratio between smokers and nonsmokers (P = 0.243). However, SDRA revealed that smokers' vessels showed both an increased level of arterial baseline diameter fluctuation before flicker stimulation (P = 0.005) and an increased stiffness of retinal arterioles (P = 0.035) compared with those in nonsmokers. These differences were unrelated to intraocular pressure or systemic blood pressure. Conclusions.: SDRA shows promise as a tool for the assessment of vessel physiology. Further studies are needed to explore its application in patients with vascular diseases.

1 August 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
RHRebekka Heitmar
Rebekka Heitmar
RCRobert P. Cubbidge
Robert P. Cubbidge
GLGregory Y. H. Lip
Gregory Y. H. Lip
Doina GherghelDoina Gherghel
Doina Gherghel
ABAndrew D. Blann
Andrew D. Blann
Purpose.: Cardiac function, such as heart rate variability, is abnormal in coronary artery disease, but its relation with the function of ocular and nail-fold blood vessels is unknown. The hypothesis was that there is abnormal retinal and peripheral microvascular endothelial function compared with large blood vessel and cardiac function. Twenty-four patients with coronary artery disease (CAD) and 30 healthy, age- and sex-matched control subjects were enrolled in the study. Methods.: Peripheral microcirculatory function was measured with continuous retinal vessel diameter assessment and nail-fold capillaroscopy. Systemic vascular function was evaluated by 24-hour blood pressure, arterial stiffness, low (LF)- and high (HF)-frequency heart rate variability, ECG monitoring, and the plasma markers von Willebrand factor (vWf) and soluble E selectin. Results.: Peripheral nail-fold capillary (P = 0.009) and retinal vessel (average baseline corrected flicker response [BFR]; P = 0.034) responses and reaction time in response to flicker (P = 0.016) were significantly different in patients compared with controls. Furthermore, patients demonstrated higher arterial stiffness (P = 0.005), LF and HF heart rate variability (P = 0.004, P = 0.006), and vWf level (P = 0.044), but there was no difference in soluble E selectin level (P = 0.278). In the CAD patients, LF and HF heart rate variability both correlated with average BFR (r = 0.58, P = 0.004; r = −0.6, P = 0.003, respectively). There was no such relationship in the healthy controls. Conclusions.: Microcirculatory abnormalities of the retina and nail-fold vessels are present in CAD. The two indices of heart rate variability correlated with an index of ocular vessel responses. The latter may be a surrogate marker of abnormal heart rate variability in CAD.