Rehman Ansari

Rehman Ansari

Auto-generated profile, based on publicly available information

Rehman Ansari

Univ. College London (United Kingdom)

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2018 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
RARehman Ansari
Rehman Ansari
EZEdward Z. Zhang
Edward Z. Zhang
ADAdrien Desjardins
Adrien Desjardins
PBPaul C. Beard
Paul C. Beard
A miniature forward-viewing endoscopic probe that provides high-resolution 3D photoacoustic images is demonstrated. The probe is of outer diameter 3.2 mm and comprised of a transparent Fabry-Pérot (FP) polymer-film ultrasound sensor that is located at the distal end of a rigid optical fiber bundle. Excitation laser pulses are coupled simultaneously into all cores of the bundle and are transmitted through the FP sensor to provide wide-field tissue illumination at the distal end. The resulting photoacoustic waves are mapped in 2D by sequentially scanning the input end of the bundle with an interrogation laser beam in order to individually address different points on the FP sensor. In this way, the sensor acts as a high-density ultrasound array that is comprised of 50,000 individual elements, each of which is 12 µm in diameter, within the 3.2 mm diameter footprint of the probe. The fine spatial sampling that this affords, along with the wide bandwidth (f-3dB = 34 MHz) of the sensor, enables a high-resolution photoacoustic image to be reconstructed. The measured on-axis lateral resolution of the probe was depth-dependent and ranged from 45-170 µm for depths between 1 and 7 mm, and the vertical resolution was 31 µm over the same depth range. The system was evaluated by acquiring 3D images of absorbing phantoms and the microvascular anatomies of a duck embryo and mouse skin. Excellent image fidelity was demonstrated. It is anticipated that this type of probe could find application as a tool for guiding laparoscopic procedures, fetal surgery and other minimally invasive interventions that require a millimeter-scale forward-viewing 3D photoacoustic imaging probe.

29 October 2019 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
EMEfthymios Maneas
Efthymios Maneas
RARosalind Aughwane
Rosalind Aughwane
NHNam Huynh
Nam Huynh
Wenfeng XiaWenfeng Xia
Wenfeng Xia
RARehman Ansari
Rehman Ansari
ADAdrien Desjardins
Adrien Desjardins
Minimally invasive fetal interventions require accurate imaging from inside the uterine cavity. Twin‐to‐twin transfusion syndrome (TTTS), a condition considered in this study, occurs from abnormal vascular anastomoses in the placenta that allow blood to flow unevenly between the fetuses. Currently, TTTS is treated fetoscopically by identifying the anastomosing vessels, and then performing laser photocoagulation. However, white light fetoscopy provides limited visibility of placental vasculature, which can lead to missed anastomoses or incomplete photocoagulation. Photoacoustic (PA) imaging is an alternative imaging method that provides contrast for haemoglobin, and in this study, two PA systems were used to visualise chorionic (fetal) superficial and subsurface vasculature in human placentas. The first system comprised an optical parametric oscillator for PA excitation and a 2D Fabry‐Pérot cavity ultrasound sensor; the second, light emitting diode arrays and a 1D clinical linear‐array ultrasound imaging probe. Volumetric photoacoustic images were acquired from ex vivo normal term and TTTS treated placentas. It was shown that superficial and subsurface branching blood vessels could be visualised to depths of approximately 7 mm, and that ablated tissue yielded negative image contrast. This study demonstrated the strong potential of PA imaging to guide minimally invasive fetal therapies.

12 November 2020 in Optics Letters
Verified
Journal Article
Open access
RARehman Ansari
Rehman Ansari
EZEdward Z. Zhang
Edward Z. Zhang
ADAdrien E. Desjardins
Adrien E. Desjardins
PBPaul C. Beard
Paul C. Beard
A miniature flexible photoacoustic endoscopy probe that provides high-resolution 3D images of vascular structures in the forward-viewing configuration is described. A planar Fabry–Perot ultrasound sensor with a − 3 d B bandwidth of 53 MHz located at the tip of the probe is interrogated via a flexible fiber bundle and a miniature optical relay system to realize an all-optical probe measuring 7.4 mm in outer diameter at the tip. This approach to photoacoustic endoscopy offers advantages over previous piezoelectric based distal-end scanning probes. These include a forward-viewing configuration in widefield photoacoustic tomography mode, finer spatial sampling (87 µm spatial sampling interval), and wider detection bandwidth (53 MHz) than has been achievable with conventional ultrasound detection technology and an all-optical passive imaging head for safe endoscopic use.

28 February 2020 in Optics Express
Verified
Journal Article
Open access
DMDylan M. Marques
Dylan M. Marques
JGJames A. Guggenheim
James A. Guggenheim
RARehman Ansari
Rehman Ansari
EZEdward Z. Zhang
Edward Z. Zhang
PBPaul C. Beard
Paul C. Beard
PMPeter Munro
Peter Munro
Fabry-Pérot (FP) etalons are used as filters and sensors in a range of optical systems. Often FP etalons are illuminated by collimated laser beams, in which case the transmitted and reflected light fields can be calculated analytically using well established models. However, FP etalons are sometimes illuminated by more complex beams such as focussed Gaussian beams, which may also be aberrated. Modelling the response of FP etalons to these beams requires a more sophisticated model. To address this need, we present a model that can describe the response of an FP etalon that is illuminated by an arbitrary beam. The model uses an electromagnetic wave description of light and can therefore compute the amplitude, phase and polarization of the optical field at any position in the system. It can also account for common light delivery and detection components such as lenses, optical fibres and photo-detectors, allowing practical systems to be simulated. The model was validated against wavelength resolved measurements of transmittance and reflectance obtained using a system consisting of an FP etalon illuminated by a focussed Gaussian beam. Experiments with focal spot sizes ranging from 30 µm to 250 µm and FP etalon mirror reflectivities in the range 97.2 % to 99.2 % yielded excellent visual agreement between simulated and experimental data and an average error below 10% for a range of quantitative comparative metrics. We expect the model to be a useful tool for designing, understanding and optimising systems that use FP etalons.

24 April 2020 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
EMEfthymios Maneas
Efthymios Maneas
RARosalind Aughwane
Rosalind Aughwane
NHNam Huynh
Nam Huynh
Wenfeng XiaWenfeng Xia
Wenfeng Xia
RARehman Ansari
Rehman Ansari
ADAdrien Desjardins
Adrien Desjardins
Successful therapy of twin‐to‐twin transfusion syndrome requires accurate imaging to guide laser photocoagulation of the anastomosing placental vessels. Photoacoustic (PA) imaging is an alternative imaging method that provides contrast for hemoglobin, and in this study, it was used to visualize chorionic superficial and subsurface vasculature in human placentas. The strong potential of PA imaging to guide minimally invasive fetal therapies was demonstrated.Further details can be found in the article by Efthymios Maneas, Rosalind Aughwane, Nam Huynh, et al. (e201900167). image

19 December 2013 in Optics Letters
Verified
Journal Article
Closed access
PDF file
RARehman Ansari
Rehman Ansari
CMChristian Myrtus
Christian Myrtus
RARedouane Aherrahrou
Redouane Aherrahrou
Jeanette ErdmannJeanette Erdmann
Jeanette Erdmann
ASAchim Schweikard
Achim Schweikard
GHGereon Hüttmann
Gereon Hüttmann
We present an ultrahigh-resolution, high-speed spectral domain optical coherence phase microscopy (SD-OCPM) system that combines submicrometer transverse spatial resolution and subnanometer optical path length sensitivity, with an acquisition speed of over 217,000  voxels/s. The proposed SD-OCPM system overcomes two significant drawbacks of traditional common-path interferometers—limited transverse spatial resolution and suboptimal detection sensitivity—while maintaining phase stability that is comparable with common-path interferometer setups. The transverse and axial spatial resolution of the setup is measured to be 0.6 and 1.9 μm, respectively, with a phase sensitivity of 0.0027 rad (corresponds to optical path length sensitivity of 110 pm). High-speed acquisition allows for phase-sensitive 4D imaging of biological samples with subcellular resolution.