1 December 2015 in Thin Solid Films
1 July 2016 in Defect and Diffusion Forum
The present studies characterize and evaluate the fracture toughness at the surface AISI 8620 with hard coating. The hard coatings FeB and Fe2B were formed using the boriding dehydrated paste at temperatures 1223 and 1273 K with 6 and 8 h exposure time, respectively. The presence of hard coatings formed on the surface AISI 8620 were confirmed by the classical metallographic technique combined with X-ray diffraction analysis. The distribution of alloying elements was determined by Energy Dispersive Spectroscopy (EDS). The fracture toughness of the hard coatings on AISI 8620 was estimated using a Vicker microindentation induced fracture testing of 15 and 35 μm from the surface, applying four load (0.49, 0.98,1.96 and N). The microcrack generated at the corner of the microindentation was considered as an experimental parameter and the tree model Palmqvist crack model was employed to determine the fracture toughness. The adherence of the hard coatings/substrate was evaluate in qualitative form though the VDI 3198 by testing Rockwell C and observed by Scanning Electron Microscopy (SEM). The formation of hard layers was obtained in the range of 100-130 μm, results of XRD present phases FeB, Fe2B, CrB and MnB, the values obtained of Kc are in the range of 2.3 to 4.1 MPam1⁄2 and results of acceptable adhesion HF4 patterns for conditions 6 h of treatment
1 February 2017 in Defect and Diffusion Forum
The paper also presents the growth kinetics of the hard layers on the surface grade machinery steels type AISI 9840 with a boron dehydrated paste. The thermochemical treatment was performed at three different temperatures: 1173, 1223, and 1273 K, with 2, 4, 6, and 8 h treatment time for each temperature. The presence of the hard layers FeB and Fe2B formed on the surface AISI 9840 was confirmed by cross sectional observation by scanning electron microscopy (SEM), XRD analysis and the distribution of alloy elements from hard layers was confirmed by energy dispersive spectroscopy (EDS). Using the law of parabolic growth the mobility of boron was included potential influence of boron, treatment time, temperature and time incubation in hard layers. Finally, nanoindentation technique test the modulus and hardness are obtained of the FeB and Fe2B hard layers.
5 September 2017 in MRS Advances
1 July 2015 in Defect and Diffusion Forum
The present study reports the growth of layers formed in the surface of the boride steel AISI W2; by the application of the dehydrated paste-pack boriding process and using three different temperatures at 1173, 1223 and 1273 K, with 2, 4, 6 and 8 h of exposure. The substrate and the boride Fe2B were analysed quantitatively and qualitatively. The growth of the boride layer Fe2B was examined using optical microscopy (OM), scanning electron microscopy (SEM-EDS) and X-ray diffraction (XRD). The properties were mechanically evaluated, using a Vickers indenter with loads of 0.5 and 1 N, with a constant distance of 15 μm and 30 μm. To determine the fracture toughness (Kc) and the adherence of the boride layer Fe2B, the Rockwell C test method (VDI 3198) was used. The morphology present in the boride Fe2B layer showed a smooth flat, whit ranged thickness from 13.96 ± 1.61 μm to 79.86 ± 4.13 μm. The presence of boride Fe2B layers of steel substrate was confirmed by XRD and the distribution of alloying elements by Energy Disperses for Spectroscopy (EDS). The hardness of the boride layers Fe2B ranged from 157 9± 17 to 1875 ± 25 HV. The fracture toughness of boride Fe2B layer observed ranged from 4.15 to 4.75 MPam1/2. The boride layer has a scale delamination H3 to H6. The boride layers formed in the surface have the function to increase the service life of W2 steels used in the industry.
1 February 2017 in Defect and Diffusion Forum
One of the most used in the field of medicine for the treatment of tibial shaft fractures internal fixation methods is by osteosynthesis plates, the most common plate limited contact dynamic compression (DCP-LC) [1]. This paper presents the results of the fracture site grade 1, where the contact plate and the bone callus area on plates made of bone (LVM stainless steel, titanium alloy different biomedical materials and cobalt alloy), in recovery conditions 1% (one week of recovery), 50% (three weeks of recovery), 75% (six weeks of recovery) and 100%. The fractured tibia bone was modeled with an ideal geometry in CAD [2], modeling of commercial DCP-LC plate was obtained by parameterization of the part using a coordinate machine equipment for the exact geometry. The finite element method for the analysis of each case under the same loads and boundary conditions is used, the results were used to determine stress concentrations in the displacement plate and the fracture callus in the load direction, to have a starting point in the optimization of the geometry from a commercial plate minimizing mass while determining that the material has faster and better biocompatibility with the human body recovery. The results obtained show that the plate under the conditions of three different types of biomaterials has a greater stress concentration in the part located in the fracture zone from stage with 1% recovery between the surfaces of the bone callus upper and lower, keeping this a significant effect on the recovery of the fracture. The compression and tension strength that occur in the intact part of the bone and the tibial fracture interface at different stages of osseous healing have been investigated, The results were compared and presented, showing that the stress distribution in the callus to 1% recovery in the stainless steel plate indicate considerable compression in the area of the callus with this causing deterioration in the area fracture because the callus is not strengthened by contact between fractured bone by increasing the recovery time, the results also indicate that the titanium plate is the one with the lower shielding effect [3] according to the distribution of contact stresses according to the recovery period in the part of callus, making it the material of which the best adaptability to the bone is obtained.