1 February 2020 in Soft Robotics
Wireless capsule endoscopes have revolutionized diagnostic procedures in the gastrointestinal (GI) tract by minimizing discomfort and trauma. Biopsy procedures, which are often necessary for a confirmed diagnosis of an illness, have been incorporated recently into robotic capsule endoscopes to improve their diagnostic functionality beyond only imaging. However, capsule robots to date have only been able to acquire biopsy samples of superficial tissues of the GI tract, which could generate false-negative diagnostic results if the diseased tissue is under the surface of the GI tract. To improve their diagnostic accuracy for submucosal tumors/diseases, we propose a magnetically actuated soft robotic capsule robot, which takes biopsy samples in a deep tissue of a stomach using the fine-needle biopsy technique. We present the design, control, and human–machine interfacing methods for the fine-needle biopsy capsule robot. Ex vivo experiments in a porcine stomach show 85% yield for the biopsy of phantom tumors located underneath the first layers of the stomach wall.
7 October 2015 in IEEE/ASME Transactions on Mechatronics
This paper introduces a new 5-D localization method for an untethered meso-scale magnetic robot, which is manipulated by a computer-controlled electromagnetic system. The developed magnetic localization setup is a 2D array (8 × 8) of mono-axial Hall-effect sensors, which measure the perpendicular magnetic fields at their given positions. We introduce two steps for localizing a magnetic robot more accurately. First, the dipole-modeled magnetic field of the electromagnet is subtracted from the measured data in order to determine the robot's magnetic field. Second, the subtracted magnetic field is twice differentiated in the perpendicular direction of the array, so that the effect of the electromagnetic field in the localization process is minimized. Five variables regarding the position and orientation of the robot are determined by minimizing the error between the measured magnetic field and the modeled magnetic field in an optimization method. The resulting position error is 2.1 ± 0.8 mm and angular error is 6.7 ± 4.3° within the applicable range (5 cm) of magnetic field sensors at 200 Hz. The proposed localization method would be used for the position feedback control of untethered magnetic devices or robots for medical applications in the future.
2 April 2020 in Advanced Materials
Bioinspired elastomeric fibrillar surfaces have significant potential as reversible dry adhesives, but their adhesion performance is sensitive to the presence of liquids at the contact interface. Like their models in nature, many artificial mimics can effectively repel water, but fail when low‐surface‐tension liquids are introduced at the contact interface. A bioinspired fibrillar adhesive surface that is liquid‐superrepellent even toward ultralow‐surface‐tension liquids while retaining its adhesive properties is proposed herein. This surface combines the effective adhesion principle of mushroom‐shaped fibrillar arrays with liquid repellency based on double re‐entrant fibril tip geometry. The adhesion performance of the proposed microfibril structures is retained even when low‐surface‐tension liquids are added to the contact interface. The extreme liquid repellency enables real‐world applications of fibrillar adhesives for surfaces covered with water, oil, and other liquids. Moreover, fully elastomeric liquid‐superrepellent surfaces are mechanically not brittle, highly robust against physical contact, and highly deformable and stretchable, which can increase the real‐world uses of such antiwetting surfaces.
28 December 2018 in IEEE Transactions on Robotics
This paper proposes a method of simultaneously calibrating magnetic localization and actuation systems for magnetically actuated robots. In this method, uncalibrated magnetic localization and actuation systems are calibrated simultaneously with minimal human intervention, which enables self-calibration, flexible reconfiguration, and long-term correctness of the system parameters. This method employs a bundle adjustment framework using a quadratic measurement model for sensors and the magnetic dipole model for actuators. The proposed method has been verified in comparison with finite element simulations and existing calibration methods for magnetic actuators and sensor arrays. In the experiments, the determinant of coefficient (R 2 value) was 99.84% for the sensor system and 99.45% for the actuator system after the calibration, comparable with individual state-of-art calibration methods of calibrating magnetic actuators and sensor arrays. This method has potential to improve the reconfigurability and long-term accuracy of magnetic robot localization and actuation systems, such as magnetically actuated capsule endoscopes.
3 July 2021 in Advanced Science
While suction cups prevail as common gripping tools for a wide range of real‐world parts and surfaces, they often fail to seal the contact interface when engaging with irregular shapes and textured surfaces. In this work, the authors propose a suction‐based soft robotic gripper where suction is created inside a self‐sealing, highly conformable and thin flat elastic membrane contacting a given part surface. Such soft gripper can self‐adapt the size of its effective suction area with respect to the applied load. The elastomeric membrane covering edge of the soft gripper can develop an air‐tight self‐sealing with parts even smaller than the gripper diameter. Such gripper shows 4 times higher adhesion than the one without the membrane on various textured surfaces. The two major advantages, underactuated self‐adaptability and enhanced suction performance, allow the membrane‐based suction mechanism to grip various three‐dimensional (3D) geometries and delicate parts, such as egg, lime, apple, and even hydrogels without noticeable damage, which can have not been gripped with the previous adhesive microstructures‐based and active suction‐based soft grippers. The structural and material simplicity of the proposed soft gripper design can have a broad use in diverse fields, such as digital manufacturing, robotic manipulation, transfer printing, and medical gripping.
22 October 2021 in Science Advances
A wireless magnetic millirobot navigates inside an ex vivo porcine brain propelled by a permanent magnetic array–based force trap.