Hui Ma

Hui Ma

Auto-generated profile, based on publicly available information

Hui Ma

Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2024 in Analytical Chemistry
Verified
Journal Article
Open access
HMHui Ma
Hui Ma
ARAiswarya A. Ramanujam
Aiswarya A. Ramanujam
JLJacqueline Linnes
Jacqueline Linnes
TKTamara Kinzer-Ursem
Tamara Kinzer-Ursem
Microfluidic techniques are widely applied in biomolecular analysis and disease diagnostic assays. While the volume of the sample that is directly used in such assays is often only femto-to microliters, the “dead volume” of solutions supplied in syringes and tubing can be much larger, even up to milliliters, increasing overall reagent use and making analysis significantly more expensive. To reduce the difficulty and cost, we designed a new chip using a low volume solution for analysis and applied it to obtain real-time data for protein–protein interaction measurements. The chip takes advantage of air/aqueous two-phase droplet flow, on-chip rapid mixing within milliseconds, and a droplet capture method, that ultimately requires only 2 μL of reagent solution. The interaction is analyzed by particle diffusometry, a nonintrusive and precise optical detection method to analyze the properties of microparticle diffusion in solution. Herein, we demonstrate on-chip characterization of human immunodeficiency virus p24 antibody–antigen protein binding kinetics imaged via fluorescence microscopy and analyzed by PD. The measured kon and koff are 1 × 106 M–1 s–1 and 3.3 × 10–4 s–1, respectively, and agree with independent measurement via biolayer interferometry and previously calculated p24-antibody binding kinetics. This new microfluidic chip and the protein–protein interaction analysis method can also be applied in other fields that require low-volume solutions to perform accurate measurement, analysis, and detection.

16 June 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ENEmilie I. Newsham
Emilie I. Newsham
EPElizabeth A. Phillips
Elizabeth A. Phillips
HMHui Ma
Hui Ma
MCMegan M. Chang
Megan M. Chang
SWSteven T. Wereley
Steven T. Wereley
JLJacqueline Linnes
Jacqueline Linnes
Wax valves were modeled and optimized for use in multi-step paper-fluidic devices. Micro-particle image velocimetry quantified microscale flow in nitrocellulose.

19 March 2024 in Analytical Chemistry
Verified
Journal Article
Closed access
HMHui Ma
Hui Ma
TKTamara Kinzer-Ursem
Tamara Kinzer-Ursem
JLJacqueline Linnes
Jacqueline Linnes

31 October 2022 in Analytical Chemistry
Verified
Journal Article
Open access
HMHui Ma
Hui Ma
SWSteven T. Wereley
Steven T. Wereley
JLJacqueline Linnes
Jacqueline Linnes
TKTamara Kinzer-Ursem
Tamara Kinzer-Ursem
The measurement and optimization of protein-protein interactions are critical in the design of biotherapeutics, biomolecular sensing elements, and functional protein-based biomaterials among other biomolecular sciences and engineering. Current gold standard assays require specifically designed core facilities, equipment, and expertise to implement the measurement, making it inconvenient for most labs unless implemented routinely. We developed a new method aiming at measuring protein binding kinetics based on microfluidics and particle diffusometry (PD), which only needs very general lab equipment, including a fluorescence microscope, a syringe pump, and a simple microchannel fabricated on a glass slide. Protein binding pairs are immobilized on two kinds of nanoparticles with different diameters using widely available conjugation chemistries. The two diluted particle suspensions are injected using a syringe pump into a Y-junction microchannel, where they bind and form particle complexes with increasing size, thereby decreasing particles' Brownian motion amplitude and diffusivity, which can be detected by PD. By taking images at a series of specific points along the microchannel, the particle diffusivity is measured at different time points after the introduction of protein-protein binding. These data are then used to quantify the protein binding kinetic constant. This label-free particle-based method is simple to operate and as accurate as the current gold standard. We demonstrate the feasibility of this accessible method by quantifying the streptavidin-biotin association constant (1.74 +/- 0.51 x 107 M-1 s-1), which compares well with previously published results.

1 April 2024 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
HMHui Ma
Hui Ma
SWSteven T. Wereley
Steven T. Wereley
JLJacqueline Linnes
Jacqueline Linnes
TKTamara Kinzer-Ursem
Tamara Kinzer-Ursem
This work presents a straightforward computational method to estimate the rotational diffusion coefficient (Dr) of cells and particles of various sizes using the continuum fluid mechanics theory. We calculate the torque (Γ) for cells and particles immersed in fluids to find the mobility coefficient μ and then obtain the Dr by substituting Γ in the Einstein relation. Geometries are constructed using triangular mesh, and the model is solved with computational fluid dynamics techniques. This method is less intensive and more efficient than the widely used models. We simulate eight different particle geometries and compare the results with previous literature.

20 April 2026 in The Analyst
Verified
Journal Article
Open access
PDF file
HMHui Ma
Hui Ma
DRDavid M. Raizen
David M. Raizen
HBHaim H Bau
Haim H Bau
GravSorter: Diverse genotypes are placed in a vertical liquid column slightly denser than the worms. Gravitaxis-competent worms swim downward, while deficient worms float and are collected for downstream sorting and sequencing.