Yu Chen

Yu Chen

Auto-generated profile, based on publicly available information

Yu Chen

State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YLYi Liao
Yi Liao
Xingliang JiangXingliang Jiang
Xingliang Jiang
Zhijin ZhangZhijin Zhang
Zhijin Zhang
HZHualong Zheng
Hualong Zheng
TLTao Li
Tao Li
YCYu Chen
Yu Chen
Infrared thermal inspection is the primary way to detect transmission line conductor faults. Nevertheless, the conventional inspections are carried out at low wind speeds, causing high investment and low efficiency. Besides, the relationship between wind speed and infrared image clarity of transmission lines has yet to be investigated. In this paper, a temperature difference-based definition of infrared imaging contrast that quantifies image clarity is firstly proposed. To explore the relationship between thermal imaging contrast and wind speed, thermal cycling tests are carried out. Based on tests and membership frequency research, a method for predicting whether a clear image could be obtained is derived. In addition, the accuracy of the proposed method is verified in a natural environment. The results show that wind speed is the only variable that affects infrared imaging contrast. High clarity image can be acquired when the contrast ranges from 0.35 to 0.78. Moreover, the average error between the practical and calculated values of contrast in the natural test is 9.1%, indicating that the proposed method is effective. The conclusion in this work provides feasible guiding significance for the infrared thermal imaging inspection engineering of overhead transmission lines.

2 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
GYGuolin Yang
Guolin Yang
YLYi Liao
Yi Liao
Xingliang JiangXingliang Jiang
Xingliang Jiang
XHXiangshuai Han
Xiangshuai Han
JDJiangyi Ding
Jiangyi Ding
Zhijin ZhangZhijin Zhang
Zhijin Zhang
This paper calculates and analyzes the collision and freezing characteristics of water droplets on the cylindrical conductors with different diameters and deduces the variation law of icing weight change rate on different diameters rotating cylindrical conductors with wind speed, ambient temperature, liquid water content, and median volume diameter. Then, a prediction and value-seeking method of icing environment parameters based on rotating circular conductors is determined. The laboratory test results show that the measured values of ambient temperature T, wind speed U, liquid water content w and median volume diameter MVD are in good conformity with the reference values measured by other instruments, and the average errors of each parameter are 3.41%, 5.44%, 6.08% and 7.20%, respectively. The field natural experiment was carried out at Hunan Xuefengshan Energy Equipment Safety National Observation and Research Station. The obtained icing environmental parameters were substituted into the icing simulation calculation model of the LDQ-100 glass insulator. Compared with the field experiment results, the simulated ice shape and the field ice shape were in good agreement. The error between the numerical calculation results of the icing weight and the field icing weight of the experimental insulator was less than 6%.