Thomas Phlips

Thomas Phlips

Auto-generated profile, based on publicly available information

Thomas Phlips

Department of Cardiology and Jessa & Science, Jessa Hospital, 3500 Hasselt, Belgium

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
PTPhilippe Taghji
Philippe Taghji
MHMilad El Haddad
Milad El Haddad
TPThomas Phlips
Thomas Phlips
MWMichael Wolf
Michael Wolf
SKSebastien Knecht
Sebastien Knecht
MDMattias Duytschaever
Mattias Duytschaever

1 February 2012 in JACC
Verified
Journal Article
Closed access
BGBernhard L. Gerber
Bernhard L. Gerber
MRMichel F. Rousseau
Michel F. Rousseau
SASylvie A. Ahn
Sylvie A. Ahn
JWJean-Benoît le Polain de Waroux
Jean-Benoît le Polain de Waroux
APAnne-Catherine Pouleur
Anne-Catherine Pouleur
JVJean-Louis J. Vanoverschelde
Jean-Louis J. Vanoverschelde

1 April 2017 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
MHMilad El Haddad
Milad El Haddad
PTPhilippe Taghji
Philippe Taghji
TPThomas Phlips
Thomas Phlips
MWMichael Wolf
Michael Wolf
ADAnthony Demolder
Anthony Demolder
MDMattias Duytschaever
Mattias Duytschaever
Background—: Pulmonary vein reconnection (PVR) still determines recurrences of atrial fibrillation after contact force (CF)–guided pulmonary vein isolation. We studied whether acute PVR (adenosine and waiting time) and late PVR (at repeat) are explained by incomplete transmurality and contiguity within the deployed radiofrequency circle. Methods and Results—: We analyzed 42 CF-guided ipsilateral pulmonary vein isolation procedures. For each radiofrequency tag within the circle, we collected data reflecting lesion depth (time of application, power, impedance drop [Δ-Imp], CF, force–time integral [FTI], and ablation index [AI]) and contiguity (automated interlesion distance [ILD]). Ablation line contiguity index (ALCI) was developed as a novel automated algorithm combining depth and contiguity into one single criterion. Each circle was subdivided into 10 segments. For each segment, we determined its weakest link by annotating time min , power min , Δ-Imp min , CF min , FTI min , AI min , ILD max , and ALCI min . Compared with segments without PVR (n=758), PVR segments (n=44) were characterized by lower Δ-Imp min (4.8 versus 7.4 Ω), CF min (8.5 versus 11.8 g), FTI min (351 versus 473 gs), AI min (367 versus 408 arbitrary unit [au]), and higher ILD max (6.8 versus 5.5 mm). ALCI min was significantly lower in segments with PVR (74% versus 104%; P <0.001) and was associated with the highest accuracy to predict durable segments (area under the curve=0.73). Conclusions—: In CF-guided pulmonary vein isolation, PVR is explained by lack of both lesion depth and contiguity within the deployed radiofrequency circle. ALCI, a novel measure combining contiguity and depth, is the most accurate predictor for durable segments. By avoiding weak links in the ablation chain, ALCI-guided ablation is expected to improve success rate of point-by-point radiofrequency ablation.

1 April 2020 in Heart Rhythm
Verified
Journal Article
Closed access
MDMattias Duytschaever
Mattias Duytschaever
JPJan De Pooter
Jan De Pooter
ADAnthony Demolder
Anthony Demolder
MHMilad El Haddad
Milad El Haddad
TPThomas Phlips
Thomas Phlips
RTRene Tavernier
Rene Tavernier

2 June 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
AAAnte Anić
Ante Anić
TPThomas Phlips
Thomas Phlips
TBToni Brešković
Toni Brešković
PKPieter Koopman
Pieter Koopman
SGSteven Girouard
Steven Girouard
JVJohan Vijgen
Johan Vijgen
Aims: Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. Methods and results: ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation (PVI) durability using the CENTAURI System in conjunction with the TactiCath SE, StablePoint, and ThermoCool ST ablation catheters. Patients with paroxysmal or persistent AF were treated at two centres. Patients were analysed in five cohorts based upon ablation settings, catheter, and mapping system. Pulsed field ablation was performed in 82 patients (74% male, 42 paroxysmal AF). Pulmonary vein isolation was achieved in 100% of pulmonary veins (322/322) with first-pass isolation in 92.2% (297/322). There were four serious adverse events of interest (three vascular access complications and one lacunar stroke). Eighty patients (98%) underwent invasive remapping. Pulsed field ablation development Cohorts 1 and 2 showed a per-patient isolation rate of 38% and 26% and a per-PV isolation rate of 47% and 53%, respectively. Optimized PFA Cohorts 3–5 showed a per-patient isolation rate of 60%, 73%, and 81% and a per-PV isolation rate of 84%, 90%, and 92%, respectively. Conclusion: ECLIPSE AF demonstrated that optimized PFA using the CENTAURI System with three commercial, contact force-sensing, solid-tip focal ablation catheters resulted in transmural lesion formation and high proportion of durable PVI with a favourable safety profile, thus providing a viable treatment option for AF that integrates with contemporary focal ablation workflows.

1 July 2019 in Heart Rhythm
Verified
Journal Article
Closed access
MWMichael Wolf
Michael Wolf
MHMilad El Haddad
Milad El Haddad
VWVincent De Wilde
Vincent De Wilde
TPThomas Phlips
Thomas Phlips
JPJan De Pooter
Jan De Pooter
MDMattias Duytschaever
Mattias Duytschaever