Jafar Mohammadi

Jafar Mohammadi

Auto-generated profile, based on publicly available information

Jafar Mohammadi

Western University, 1151 Richmond St N, London, ON N6A 5B9, Canada

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2014 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
JMJafar Mohammadi
Jafar Mohammadi
SVSadegh Vaez-Zadeh
Sadegh Vaez-Zadeh
SASaeed Afsharnia
Saeed Afsharnia
EDEhsan Daryabeigi
Ehsan Daryabeigi
In this paper, a combined vector and direct power control (CVDPC) is proposed for the rotor side converter (RSC) of doubly fed induction generators (DFIGs). The control system is based on a direct current control by selecting appropriate voltage vectors from a switching table. In fact, the proposed CVDPC enjoys the benefits of vector control (VC) and direct power control (DPC) in a compacted control system. Its benefits in comparison with VC include fast dynamic response, robustness against the machine parameters variation, lower computation, and simple implementation. On the other hand, it has benefits in comparison with DPC, including less harmonic distortion and lower power ripple. An extensive simulation study, using MATLAB/Simulink, is conducted on a 9-MW wind farm composed of six 1.5-MW DFIG-based wind turbines. The performance of the proposed CVDPC method is compared with both VC and DPC under steady-state and transient conditions. Simulation results confirm the superiority of the CVDPC over either VC or DPC.

12 July 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JMJafar Mohammadi
Jafar Mohammadi
FAFirouz Badrkhani Ajaei
Firouz Badrkhani Ajaei
GSGary Stevens
Gary Stevens
A comprehensive knowledge of the available grounding strategies and their effects is essential for design, operation, and protection of the dc microgrid. This paper investigates and compares different dc microgrid grounding strategies that involve the choice of grounding configurations and grounding devices. The impacts of different grounding strategies on line-to-ground (LG) fault detection and protection, transient LG fault current magnitude, leakage current level, common mode voltage, personnel/equipment safety, system reliability, service continuity, and insulation requirements are thoroughly investigated. LG fault response of a low-voltage dc microgrid with different grounding devices is studied by detailed simulation of a realistic study system modeled in the PSCAD software. The study results indicate that: 1) the ungrounded, bipolar solidly grounded, unipolar parallel resistance grounded, and bipolar resistance grounded dc microgrids enable LG fault ride through, due to the low fault current; 2) the unipolar solidly grounded, bipolar solidly grounded, diode-grounded, and thyristor-grounded dc microgrids experience significantly large transient discharge currents under LG faults; and 3) the unipolar solidly grounded, diode-grounded, thyristor-grounded, and unipolar low-resistance-grounded dc microgrids provide considerable steady-state LG fault current which necessitates fast detection and clearance of faults.

1 February 2014 in Energy Conversion and Management
Verified
Journal Article
Closed access
JMJ. Mohammadi
J. Mohammadi
SAS. Afsharnia
S. Afsharnia
SVS. Vaez-Zadeh
S. Vaez-Zadeh

18 April 2019 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
MJMohammad Jahanpour-Dehkordi
Mohammad Jahanpour-Dehkordi
SVSadegh Vaez-Zadeh
Sadegh Vaez-Zadeh
JMJafar Mohammadi
Jafar Mohammadi
Fast transient and smooth steady state performance of wind energy conversion systems (WECSs) is essential for sustained power conversion and grid code fulfilment including low voltage ride through capability. In this paper, an analysis of permanent magnet synchronous generator (PMSG) based WECSs under vector control and direct torque control provides the basis for combining salient features of the two control methods into a reliable and effective control system to provide enhanced machine performance. The system includes two hysteresis current controllers in connection with an inverter-switching table. The proposed control provides fast transient and smooth steady state performance for machine side converter of PMSGs, which controls DC-link voltage under grid fault conditions. Extensive simulation results on a 2 MW PMSG based WECS demonstrate the desired performance of the proposed control system under both grid-normal and -fault conditions.

8 June 2016 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
JMJafar Mohammadi
Jafar Mohammadi
SASaeed Afsharnia
Saeed Afsharnia
SVSadegh Vaez‐Zadeh
Sadegh Vaez‐Zadeh
SFShahrokh Farhangi
Shahrokh Farhangi
Due to the latest grid codes, wind turbines (WTs) are required to remain connected to grid under grid faults and supply reactive power into the grid. So, this paper proposes an improved fault ride through (FRT) strategy for doubly fed induction generators (DFIGs) under both symmetrical and asymmetrical grid faults. The proposed strategy is realized through active and passive FRT compensators. The active compensator is performed through control of the rotor‐ and grid‐side converters of DFIGs to limit the stator and rotor over currents and inject reactive power into the grid to support the grid voltage recovery, respectively. The passive compensator is based on a three‐phase rotor current limiter (RCL) resistor located in series with the rotor windings. It considerably reduces the rotor and stator overcurrent at the instants of grid faults occurrence and clearance. The proposed strategy decreases the stator and rotor over currents, electromagnetic torque oscillations and DC‐link over voltage and also support grid voltage by supplying reactive power into the grid. In this way, the DFIG can fulfill the FRT requirements of the latest grid codes. Simulation studies using MATLAB/SIMULINK are conducted on a 1.5 MW DFIG‐based WT to validate the effectiveness of the proposed FRT strategy.

14 May 2018 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
JMJafar Mohammadi
Jafar Mohammadi
SVSadegh Vaez‐Zadeh
Sadegh Vaez‐Zadeh
EEEsmaeil Ebrahimzadeh
Esmaeil Ebrahimzadeh
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
This study proposes a combined control method based on vector control (VC) and virtual flux direct power control (VFDPC) for grid‐side converter of doubly fed induction generator (DFIG)‐based wind energy conversion systems (WECSs). VC gives lower power ripple with a slower dynamic response, while VFDPC provides a faster dynamic response, but higher power ripple. So, an analogy between VC and VFDPC is proved first and then used to propose a combined control method that takes the advantages of VC and VFDPC in an integrated control system. In the combined control method, the grid currents are directly controlled using hysteresis controllers and optimal switching table. It has several advantages compared to VC including faster power/current dynamic response, robustness to grid filter parameter variation, lower computation, and simple implementation. On the other hand, its advantages compared to VFDPC include less current harmonic distortion, lower power ripple, and robustness to measurement noise. To demonstrate the effectiveness and robustness of the combined control method, simulation results on a 1.5 MW DFIG‐based WECS are provided and compared with both VC and VFDPC under different steady‐state and transient conditions. The simulation results verify the superiority of the proposed method over either VC or VFDPC.