Jason Craft

Jason Craft

Auto-generated profile, based on publicly available information

Jason Craft

Department of Cardiac Imaging, St. Francis Hospital and Heart Center, Roslyn, NY

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2023 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
JCJason Craft
Jason Craft
YLYulee Li
Yulee Li
NNNiloofar Fouladi Nashta
Niloofar Fouladi Nashta
JWJonathan Weber
Jonathan Weber
Purpose: Highly accelerated compressed sensing cine has allowed for quantification of ventricular function in a single breath hold. However, compared to segmented breath hold techniques, there may be underestimation or overestimation of LV volumes. Furthermore, a heterogeneous sample of techniques have been used in volunteers and patients for pre-clinical and clinical use. This can complicate individual comparisons where small, but statistically significant differences exist in left ventricular morphological and/or functional parameters. This meta-analysis aims to provide a comparison of conventional cine versus compressed sensing based reconstruction techniques in patients and volunteers. Methods: Two investigators performed systematic searches for eligible studies using PubMed/MEDLINE and Web of Science to identify studies published 1/1/2010-3/1/2021. Ultimately, 15 studies were included for comparison between compressed sensing cine and conventional imaging. Results: Compared to conventional cine, there were small, statistically significant overestimation of LV mass, underestimation of stroke volume and LV end diastolic volume (mean difference 2.65 g [CL 0.57–4.73], 2.52 mL [CL 0.73–4.31], and 2.39 mL [CL 0.07–4.70], respectively). Attenuated differences persisted across studies using prospective gating (underestimated stroke volume) and non-prospective gating (underestimation of stroke volume, overestimation of mass). There were no significant differences in LV volumes or LV mass with high or low acceleration subgroups in reference to conventional cine except slight underestimation of ejection fraction among high acceleration studies. Reduction in breath hold acquisition time ranged from 33 to 64%, while reduction in total scan duration ranged from 43 to 97%. Conclusion: LV volume and mass assessment using compressed sensing CMR is accurate compared to conventional parallel imaging cine.

31 October 2024 in Journal of Cardiac Failure
Verified
Journal Article
Closed access
LWLin Wang
Lin Wang
JWJonathan Weber
Jonathan Weber
JCJason Craft
Jason Craft
MPMichael Passick
Michael Passick
OKOmar Khalique
Omar Khalique
JCJ. Jane Cao
J. Jane Cao

27 April 2024 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
JCJason Craft
Jason Craft
JWJonathan Weber
Jonathan Weber
YLYulee Li
Yulee Li
JCJoshua Y. Cheng
Joshua Y. Cheng
NDNancy Diaz
Nancy Diaz
RBRene M. Botnar
Rene M. Botnar

16 June 2021 in La radiologia medica
Verified
Journal Article
Closed access
PDF file
JCJason Craft
Jason Craft
YLYulee Li
Yulee Li
SBSalman Bhatti
Salman Bhatti
JCJie Jane Cao
Jie Jane Cao

30 April 2025 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
JCJason Craft
Jason Craft
RPRoosha Parikh
Roosha Parikh
JCJosh Y. Cheng
Josh Y. Cheng
NDNancy Diaz
Nancy Diaz
KKKarl P. Kunze
Karl P. Kunze
RBRene M. Botnar
Rene M. Botnar
Background: Serial assessment of the thoracic aorta with magnetic resonance angiography (MRA) is desirable due to 3D volumetric dataset, high spatial resolution, and lack of ionizing radiation. Electrocardiogram (ECG) gated, contrast-enhanced (CE), inversion recovery gradient echo MRA is efficient and historically provides low artifact burden, but the window for imaging with weak albumin binding extracellular gadolinium based contrast agents is small. Our purpose was to acquire whole-chest gated CE-MRA with 1.2 mm3 resolution using image-based navigator (iNAV) for motion correction/contrast monitoring, and variable density sampling in 4–5 min. Image quality and vessel diameter reproducibility are assessed against time resolved MRA (TR-MRA).Methods: iNAV CE-MRA and TR-MRA were obtained prospectively in 40 patients and reviewed by 3 blinded cardiologists for vessel diameter and image quality rated on a four point scale: (1) non-diagnostic; (2) poor-significant blurring; (3) good-mild blurring; and (4) excellent. Reproducibility and image quality were evaluated using the concordance correlation statistic and Cohen's kappa with mean differences evaluated using paired t-tests and repeat-measures ANOVA.Results: iNAV CE-MRA scan time was 4.2 ± 0.7 min. iNAV CE-MRA quality score was higher (p < .001); average difference was 1.4 ± .08 at the sinus of Valsalva (SOV), 1.3 ± .08 at the sinotubular junction (STJ), and .87 ± .10 at the ascending aorta (AAO). Major/minor diameter interobserver agreement was better for iNAV CE-MRA (SOV ICC = .87–.93; STJ ICC = .95–.96; AAO ICC = .96–.97) vs. TR-MRA (SOV ICC = .69–.82; STJ ICC = .78–.83; AAO ICC = .89), as was intraobserver agreement (SOV ICC = .93–.95; STJ ICC = .94–.96; AAO ICC = .96–.97) vs. TR-MRA (SOV ICC = .81–.88; STJ ICC = .72–.73; AAO ICC = .87–.93).Conclusion: iNAV CE-MRA is feasible within a clinically reasonable scan time, provides superior image quality, and measurement reproducibility vs. TR-MRA.

23 August 2023 in The American Journal of Cardiology
Verified
Journal Article
Closed access
JCJason Craft
Jason Craft
JWJonathan Weber
Jonathan Weber
JCJane J. Cao
Jane J. Cao
MPMichael Passick
Michael Passick
NNNora Ngai
Nora Ngai
EBEddy Barasch
Eddy Barasch