Ruzairi Abdul Rahim

Ruzairi Abdul Rahim

Auto-generated profile, based on publicly available information

Ruzairi Abdul Rahim

Universiti Teknologi Malaysia

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2010
Verified
Conference Paper
Closed access
ZZZulkarnay Zakaria
Zulkarnay Zakaria
MMMuhammad Saiful Badri Mansor
Muhammad Saiful Badri Mansor
AJAishah Hartini Jahidin
Aishah Hartini Jahidin
MAMohd Shuhanaz Zanar Azlan
Mohd Shuhanaz Zanar Azlan
RRRuzairi Abdul Rahim
Ruzairi Abdul Rahim
Magnetic flux leakage (MFL) is a method used in oil and gas piping systems which has potential in medical gas piping inspection, cleaning and gauging tasks without interrupting the pipeline transportation process. MFL is a magnetic method of nondestructive testing that applies a magnet to magnetize the steel. At areas where there is corrosion or missing metal, the magnetic field "leaks" from the steel. In this research, a system that is capable of simulating a magnetic flux leakage of different types of crack was modeled using the Finite Element Method of Magnetic (FEMM). A portion of pipelines that may contain several cracks were introduced into the software by entering all the properties needed in order to simulate the output in the magnetic field distribution and graphical representation. The disturbance in magnetic field will result in small displacement in the field. The displacement in the fields carries the actual information about the condition of the pipeline.

13 June 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JJJuliza Jamaludin
Juliza Jamaludin
RRRuzairi Abdul Rahim
Ruzairi Abdul Rahim
This paper presents an application of a charge coupled device (CCD) linear sensor and laser diode in an optical tomography (OPT) system. OPT is a non-invasive and non-intrusive tomography system consisting of an emitter with detectors. This paper is conducted in order to analyze and prove the capability of a laser with a CCD in an OPT system for detecting and measuring the diameter of an object that exists in crystal clear water. Experiments in detecting and capturing static solid and transparent objects are conducted using this hardware and software development. Statistical engineering methods were applied to analyze and validate the experimental data. Investigations of the effect of number of sensor views and object opacity level were also carried out in this paper. In conclusion, this paper has successfully developed an OPT system that is capable of detecting the appearance and measuring the diameter of objects with different opacity levels in non-flowing crystal clear water.

1 December 2011 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
PCPei Song Chee
Pei Song Chee
RRRuzairi Abdul Rahim
Ruzairi Abdul Rahim
UHU. Hashim
U. Hashim
RARashidah Arsat
Rashidah Arsat
PLPei Ling Leow
Pei Ling Leow
Planar pinch micropump with the integration of two diffuser valve elements has been reported. The fabrication of the micropump is carried out by utilizing simple hot embossing technique for microdiffuser imprinting and spin coating for membrane construction. Parameter of diffuser design is optimized via finite element analysis (FEA). The experiment result shows that the pump works well at low frequency of 29 Hz.

9 November 2020
Verified
Conference Paper
Closed access
NPNorfarhan Hidayah M. Pajar
Norfarhan Hidayah M. Pajar
NSNurul Adilla Mohd Subha
Nurul Adilla Mohd Subha
RRRuzairi Abdul Rahim
Ruzairi Abdul Rahim
FHFazilah Hassan
Fazilah Hassan
NHNorikhwan Hamzah
Norikhwan Hamzah
Commonly, solution for consensus problem with input saturation constraints utilizes a low-gain feedback approach. However, limited work has been done on the effects of weighted coupling gain. Hence, this paper studies the effect of a time-varying coupling gain on the convergence time of leader-follower consensus on both cooperative and noncooperative leader. The input of each agent is subjected to saturation. Weighted based time-varying gain are developed and applied for cooperative leader connection and noncooperative leader connection. The weighted gain is determined by the errors between the leader and follower tracking difference calculated via computer simulation. The results show that the proposed time-varying gain algorithm reaches consensus for both cooperative and non-cooperative leaders whereas low-gain was unstable.

18 April 2025
Verified
Book Chapter
Closed access
PDF file
SDShahrulnizahani Mohammad Din
Shahrulnizahani Mohammad Din
PLPei Ling Leow
Pei Ling Leow
JPJaysuman Pusppanathan
Jaysuman Pusppanathan
RRRuzairi Abdul Rahim
Ruzairi Abdul Rahim
XHXian Feng Hor
Xian Feng Hor
SASuzanna Ridzuan Aw
Suzanna Ridzuan Aw

13 June 2025 in Jurnal Teknologi (Sciences & Engineering)
Verified
Journal Article
Closed access
AMAin Eazriena Che Man
Ain Eazriena Che Man
YAYasmin AW
Yasmin AW
NYNurhafizah Abu Talip Yusof
Nurhafizah Abu Talip Yusof
SASuzanna Ridzuan Aw
Suzanna Ridzuan Aw
MSMohd Mawardi Saari
Mohd Mawardi Saari
SYSia Yee Yu
Sia Yee Yu
In the field of multiphase flow characterisation, process tomography techniques have attracted a lot of attention because they provide important insights into the internal dynamics of complicated systems. In particular, non-invasive and invasive techniques are compared and several forms of process tomography utilized for multiphase regime identification are reviewed in this work, with an emphasis on industrial applications. Non-invasive process tomography methods evaluate electrical qualities or fluctuations in conductivity using external sensors or electrodes, allowing for real-time imaging and monitoring without physically altering the system. In contrast, more precise and localized measurements are made possible by invasive process tomography techniques, which entail the direct insertion of sensors or probes into the system. The comparative benefits and drawbacks of invasive and non-invasive process tomography methods for multiphase regime identification are also included in this review. It examines variables like measurement precision, spatial resolution, intrusiveness of the system, and installation needs. When choosing process tomography methods for finding multiphase regimes in industrial applications, researchers can make well-informed selections with the help of this review, which provides insights into the advantages and disadvantages of each methodology.