4 December 2024 in IEEE Transactions on Nuclear Science
Commissioning of detector systems for the High-Luminosity Large Hadron Collider (HL-LHC) is scheduled to take place between 2026 and 2028 at CERN. Application Specific Integrated Circuits (ASICs) for those systems have been in intense development over the past ten years. Some of those ASICs, as is the case of the Low Power GigaBit Transceiver (lpGBT) described in this work, have now been produced in industrial quantities and have been fully qualified for operation in the HL-LHC environments that require, where the innermost detectors are concerned, radiation hardness in excess of 1 MGy. The lpGBT is a multi-functional device, enabling data transmission between the off-detector and the on-detector systems. Data can be transmitted from the detector at 5.12 Gbit s −1 and 10.24 Gbit s −1 and to the detector at 2.56 Gbit s −1 . It implements data rate-configurable electrical links to communicate with the front-end ASICs and low-speed serial and parallel buses for experiment control. A set of analog functions for monitoring and control of the physics detectors is also included. This paper describes the functionality and the architecture of the lpGBT ASIC and reports on its radiation hardness characterization.
4 June 2021 in IEEE Transactions on Nuclear Science
We present the design and test results of a time-to-digital-converter (TDC). The TDC will be a part of the readout Application-Specific Integrated Circuit (ASIC), called endcap timing read-out chip (ETROC), to read out low-gain avalanche detectors (LGADs) for the CMS endcap timing layer (ETL) of high-luminosity large hadron collider (LHC) upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 μW for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the time of arrival (TOA) and the time over threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65-nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 and 9.9 ps with and without nonlinearity correction, respectively. The TDC block consumes 97 μW at the hit occupancy of 1%. Over a temperature range from 23 °C to 78 °C and a power supply voltage range from 1.05 to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation tolerance specifications.
1 March 2016 in Journal of Instrumentation
We report the development of a mid-board, TOSA and ROSA based miniature dual channel optical transmitter (MTx) and a transceiver (MTRx). The design transmission data rate is 5.12 Gbps per channel and receiving data rate 4.8 Gbps. MTx and MTRx are only 6 mm tall and are electrically and optically pluggable. Although the fiber TOSA/ROSA coupling is through a custom latch, the fiber uses the standard LC ferrule, flange and spring. The TOSA and ROSA with the LC coupling mechanism ensure light coupling efficiency. With the dual channel serializer LOCx2 sits under MTx, one achieves high data transmission with a small PCB footprint, and enjoys the reliability of the hermetically packaged TOSA. MTx and MTRx are designed for detector front-end readout of the ATLAS Liquid Argon Calorimeter (LAr) trigger upgrade.
1 February 2015 in Journal of Instrumentation
1 March 2014 in Journal of Instrumentation
30 March 2020 in Journal of Instrumentation
We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.