Yosef Solewicz

Yosef Solewicz

Auto-generated profile, based on publicly available information

Yosef Solewicz

Faculty of Biomedical Engineering, Technion Institute of Technology, Julius Silver Building, Haifa, 3200003, ISRAEL

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2018 in IEEE Transactions on Information Forensics and Security
Verified
Journal Article
Open access
SBSofia Belikovetsky
Sofia Belikovetsky
YSYosef A. Solewicz
Yosef A. Solewicz
MYMark Yampolskiy
Mark Yampolskiy
JTJinghui Toh
Jinghui Toh
YEYuval Elovici
Yuval Elovici
Additive manufacturing (AM, or 3D printing) is a novel manufacturing technology that has been adopted in industrial and consumer settings. However, the reliance of this technology on computerization has raised various security concerns. In this paper, we address issues associated with sabotage via tampering during the 3D printing process by presenting an approach that can verify the integrity of a 3D printed object. Our approach operates on acoustic side-channel emanations generated by the 3D printer’s stepper motors, which results in a non-intrusive and real-time validation process that is difficult to compromise. The proposed approach constitutes two algorithms. The first algorithm is used to generate a master audio fingerprint for the verifiable unaltered printing process. The second algorithm is applied when the same 3D object is printed again, and this algorithm validates the monitored 3D printing process by assessing the similarity of its audio signature with the master audio fingerprint. To evaluate the quality of the proposed thresholds, we identify the detectability thresholds for the following minimal tampering primitives: insertion, deletion, replacement, and modification of a single tool path command. By detecting the deviation at the time of occurrence, we can stop the printing process for compromised objects, thus saving time and preventing material waste. We discuss various factors that impact the method, such as background noise, audio device changes and different audio recorder positions.

1 August 2019 in Speech Communication
Verified
Journal Article
Closed access
MJMichael Jessen
Michael Jessen
JBJakub Bortlík
Jakub Bortlík
PSPetr Schwarz
Petr Schwarz
YSYosef A. Solewicz
Yosef A. Solewicz

1 January 2020 in Forensic Science International
Verified
Journal Article
Closed access
PGPavel Giverts
Pavel Giverts
SSSaad Sofer
Saad Sofer
YSYosef Solewicz
Yosef Solewicz
BVBoris Varer
Boris Varer

1 October 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HHHagai Hamami
Hagai Hamami
YSYosef Solewicz
Yosef Solewicz
DZDaniel Zur
Daniel Zur
YKYonatan Kleerekoper
Yonatan Kleerekoper
JBJoachim A. Behar
Joachim A. Behar
Premature Ventricular Contractions (PVCs) are common cardiac arrhythmias originating from the ventricles. Accurate detection remains challenging due to variability in electrocardiogram (ECG) waveforms caused by differences in lead placement, recording conditions, and population demographics. We developed uPVC-Net, a universal deep learning model to detect PVCs from any single-lead ECG recordings. The model is developed on four independent ECG datasets comprising a total of 8.3 million beats collected from Holter monitors and a modern wearable ECG patch. uPVC-Net employs a custom architecture and a multi-source, multi-lead training strategy. For each experiment, one dataset is held out to evaluate out-of-distribution (OOD) generalization. uPVC-Net achieved an AUC between 97.8% and 99.1% on the held-out datasets. Notably, performance on wearable single-lead ECG data reached an AUC of 99.1%. uPVC-Net exhibits strong generalization across diverse lead configurations and populations, highlighting its potential for robust, real-world clinical deployment.

19 January 2026 in Physiological Measurement
Verified
Journal Article
Open access
MGMárton Goda
Márton Goda
HBHelen Mary Badge
Helen Mary Badge
JKJasmeen Khan
Jasmeen Khan
YSYosef Solewicz
Yosef Solewicz
MDMoran Davoodi
Moran Davoodi
JBJoachim A Behar
Joachim A Behar
Objective. Large vessel occlusion (LVO) stroke presents a major challenge in clinical practice due to the potential for poor outcomes with delayed treatment. Treatment for LVO involves highly specialized care, in particular endovascular thrombectomy, and is available only at certain hospitals. Therefore, prehospital identification of LVO by emergency ambulance services, can be critical for triaging LVO stroke patients directly to a hospital with access to endovascular therapy. Clinical scores exist to help distinguish LVO from less severe strokes, but they are based on a series of examinations that can be time-consuming and may be impractical for patients with dementia or those who cannot follow commands due to their stroke. There is a need for a fast and reliable method to aid in the early identification of LVO. In this study, our objective was to assess the feasibility of using 30 s photoplethysmography (PPG) recording to assist in recognizing LVO stroke. Approach. A total of 88 patients, including 25 with LVO, 27 with stroke mimic (SM), and 36 non-LVO stroke patients (NL), were recorded at the Liverpool Hospital emergency department in Sydney, Australia. Demographics (age, sex), as well as morphological features and beating rate variability measures, were extracted from the PPG. A binary classification approach was employed to differentiate between LVO stroke and NL + SM (NL.SM). A 2:1 train-test split was stratified and repeated randomly across 100 iterations. Main results. The best model achieved a median test set area under the receiver operating characteristic curve of 0.77 (0.71–0.82). Significance. Our study demonstrates the potential of utilizing a 30 s PPG recording for identifying LVO stroke.

30 September 2026 in Physiological Measurement
Verified
Journal Article
Open access
LALisa Attali
Lisa Attali
YSYosef Solewicz
Yosef Solewicz
SBShany Brimer Biton
Shany Brimer Biton
Hagai HamamiHagai Hamami
Hagai Hamami
EZEran Zvuloni
Eran Zvuloni
JBJoachim A Behar
Joachim A Behar
Objective. Cardiovascular disease remains one of the leading causes of morbidity and mortality worldwide, highlighting the need for accurate risk prediction. Atrial fibrillation burden (AFB), premature ventricular contraction burden (PVCB), and T-wave alternans (TWA) have been individually associated with adverse outcomes. We hypothesized that these three digital ECG biomarkers provide complementary prognostic information for major cardiovascular endpoints and all-cause mortality (ACM), and developed a machine learning approach combining these biomarkers for risk prediction. Approach. We analyzed 81 362 Holter recordings from 54 395 individuals across 20 primary care centers in Israel. A random forest model using AFB, PVCB, TWA, and age was trained to predict 5 year risk of heart failure (HF), ischemic stroke (IS), and ACM. Main results. On the test set, best AUROCs were for HF 0.75 [95% CI: 0.74–0.77] ( n pos = 622 ), for IS 0.69 [0.66–0.71] ( n pos = 365 ), and for ACM 0.79 [0.77–0.80] ( n pos = 1060 ). Combining the three ECG-derived biomarkers showed complementary predictive value and improved discrimination by up to 10% over age alone in individuals aged < 75 years. Significance. AFB, PVCB, and TWA contribute complementary prognostic information for risk stratification. When combined with age, these biomarkers improve predictive performance compared with age alone.