Márton Goda

Mr. Márton Goda

Pázmány Péter Catholic University - Faculty of Information Technology and Bionics

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in Physiological Measurement
Verified
Journal Article
Open access
MGMárton Goda
Márton Goda
Peter CharltonPeter Charlton
Peter Charlton
JBJoachim A Behar
Joachim A Behar
Objective. Photoplethysmography is a non-invasive optical technique that measures changes in blood volume within tissues. It is commonly and being increasingly used for a variety of research and clinical applications to assess vascular dynamics and physiological parameters. Yet, contrary to heart rate variability measures, a field which has seen the development of stable standards and advanced toolboxes and software, no such standards and limited open tools exist for continuous photoplethysmogram (PPG) analysis. Consequently, the primary objective of this research was to identify, standardize, implement and validate key digital PPG biomarkers. Approach. This work describes the creation of a standard Python toolbox, denoted pyPPG , for long-term continuous PPG time-series analysis and demonstrates the detection and computation of a high number of fiducial points and digital biomarkers using a standard fingerbased transmission pulse oximeter. Main results. The improved PPG peak detector had an F1-score of 88.19% for the state-of-the-art benchmark when evaluated on 2054 adult polysomnography recordings totaling over 91 million reference beats. The algorithm outperformed the open-source original Matlab implementation by ∼5% when benchmarked on a subset of 100 randomly selected MESA recordings. More than 3000 fiducial points were manually annotated by two annotators in order to validate the fiducial points detector. The detector consistently demonstrated high performance, with a mean absolute error of less than 10 ms for all fiducial points. Significance. Based on these fiducial points, pyPPG engineered a set of 74 PPG biomarkers. Studying PPG time-series variability using pyPPG can enhance our understanding of the manifestations and etiology of diseases. This toolbox can also be used for biomarker engineering in training data-driven models. pyPPG is available on https://physiozoo.com/ .

14 September 2016 in Computing in cardiology
Verified
Conference Paper
Closed access
MGMárton Goda
Márton Goda
PHPeter Hajas
Peter Hajas

31 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MGMárton Goda
Márton Goda
TTTamás Telek
Tamás Telek
FKFerenc Kovács
Ferenc Kovács
The detailed assessment of fetal breathing movement (FBM) monitoring can be a pre-indicator of many critical cases in the third trimester of pregnancy. Standard 3D ultrasound monitoring is time-consuming for FBM detection. Therefore, this type of measurement is not common. The main goal of this research is to provide a comprehensive image about FBMs, which can also have potential for application in telemedicine. Fifty pregnancies were examined by phonography, and nearly 9000 FBMs were identified. In the case of male and female fetuses, 4740 and 3100 FBM episodes were detected, respectively. The measurements proved that FBMs are well detectable in the 20–30 Hz frequency band. For these episodes, an average duration of 1.008 ± 0.13 s (p < 0.03) was measured in the third trimester. The recorded material lasted for 16 h altogether. Based on these measurements, an accurate assessment of FBMs could be performed. The epochs can be divided into smaller-episode groups separated by shorter breaks. During the pregnancy, the rate of these breaks continuously decreases, and episode groups become more contiguous. However, there are significant differences between male and female fetuses. The proportion of the episodes which were classified into minimally 10-member episode groups was 19.7% for males and only 12.1% for females, even at the end of the third trimester. In terms of FBM detection, phonography offers a novel opportunity for long-term monitoring. Combined with cardiac diagnostic methods, it can be used for fetal activity assessment in the third trimester and make measurement appreciably easier than before.

13 April 2021 in IEEE Access
Verified
Journal Article
Open access
MGMárton Goda
Márton Goda
TTTamas Telek
Tamas Telek
This paper proposes a novel phonography-based method for Fetal Breathing Movement (FBM) detection by its excitation sounds. It requires significantly less effort than the current procedures, and it allows long-term measurement, even at home. More than 50 pregnancies in the third trimester were examined, for a minimum of 20 minutes, taking synchronous long-term measurements using a commercial phonocardiographic fetal monitor and a 3D ultrasound machine. To analyze the gained chaotic signal, the frequency band was split into single test-frequencies in the 15–35 Hz frequency band, and their signal-free (silent) zones were regarded as the starting point (SP) of the next motions. The analysis made other disturbing signals, such as fetal hiccups, trunk rotation and limb movements, or maternal heart beats, distinguishable. The dominant test-frequencies of the analysis were predicted by a Hidden Markov Model (HMM). The SPs of the motion units (episodes) were determined by some features of the FBM, applying weighting factors. The recorded material lasted for 16 hours altogether (with nearly 3.5 hours of FBM). Based on the results of HMM method, nearly 7500 FBM episodes were identified in the phonogram signal with an average length of 0.96±0.13 seconds. The procedure for phonography-based breathing movement detection can be combined with a fetal heart activity measurement, and thus allows very intensive, long-term monitoring of the fetus.

1 December 2024 in Physiological Measurement
Verified
Journal Article
Open access
KMKristóf Müller
Kristóf Müller
JHJanka Hatvani
Janka Hatvani
MKMiklós Koller
Miklós Koller
MGMárton Goda
Márton Goda
Objective. Phonocardiography has recently gained popularity in low-cost and remote monitoring, including passive fetal heart monitoring. The development of methods which analyze phonocardiographic data tries to capitalize on this opportunity, and in recent years a multitude of such algorithms and models have been published. In these approaches there is little to no standardization and multiple parts of these models have to be reimplemented on a case-by-case basis. Datasets containing heart sound recordings also lack standardization in both data storage and labeling, especially in fetal phonocardiography. Approach. We are presenting a toolbox that can serve as a basis for a future standard framework for heart sound analysis. This toolbox contains some of the most widely used processing steps and with these, complex analysis pipelines can be created. These functions can be tested individually. Main results. Due to the interdependence of the steps, we validated the current segmentation stage using two phonocardiogram (PCG) datasets, a fetal dataset comprising 50 one-minute abdominal PCG recordings, which include 6758 S1 and 6729 S2 labels and a filtered version of the dataset used in the 2022 PhysioNet Challenge, containing 413 records with 9795 S1 and 9761 S2 labels. Our results were compared to other common and publicly available segmentation methods, such as peak detection with the Neurokit2 library, and the hidden semi-Markov model by Springer et al. Our best model achieved a 96.1% F1 score and 11.7 ms mean absolute error for fetal S1 detection, and 81.3% F1 score and 50.5 ms mean absolute error for PhysioNet S1 detection. Significance. Our detection method outperformed all other tested methods on the fetal dataset and achieved results comparable to the state of the art on the PhysioNet dataset. Accurate segmentation of signals is critical for the calculation of accurate statistical measures and the creation of classification models. Our toolbox contains functions for both feature extraction and calculation of statistics which are compatible with the previous steps. All of our methods can be fine tuned for specific datasets. pyPCG is available on https://pypcg-toolbox.readthedocs.io/en/latest/.

19 January 2026 in Physiological Measurement
Verified
Journal Article
Open access
MGMárton Goda
Márton Goda
HBHelen Mary Badge
Helen Mary Badge
JKJasmeen Khan
Jasmeen Khan
YSYosef Solewicz
Yosef Solewicz
MDMoran Davoodi
Moran Davoodi
JBJoachim A Behar
Joachim A Behar
Objective. Large vessel occlusion (LVO) stroke presents a major challenge in clinical practice due to the potential for poor outcomes with delayed treatment. Treatment for LVO involves highly specialized care, in particular endovascular thrombectomy, and is available only at certain hospitals. Therefore, prehospital identification of LVO by emergency ambulance services, can be critical for triaging LVO stroke patients directly to a hospital with access to endovascular therapy. Clinical scores exist to help distinguish LVO from less severe strokes, but they are based on a series of examinations that can be time-consuming and may be impractical for patients with dementia or those who cannot follow commands due to their stroke. There is a need for a fast and reliable method to aid in the early identification of LVO. In this study, our objective was to assess the feasibility of using 30 s photoplethysmography (PPG) recording to assist in recognizing LVO stroke. Approach. A total of 88 patients, including 25 with LVO, 27 with stroke mimic (SM), and 36 non-LVO stroke patients (NL), were recorded at the Liverpool Hospital emergency department in Sydney, Australia. Demographics (age, sex), as well as morphological features and beating rate variability measures, were extracted from the PPG. A binary classification approach was employed to differentiate between LVO stroke and NL + SM (NL.SM). A 2:1 train-test split was stratified and repeated randomly across 100 iterations. Main results. The best model achieved a median test set area under the receiver operating characteristic curve of 0.77 (0.71–0.82). Significance. Our study demonstrates the potential of utilizing a 30 s PPG recording for identifying LVO stroke.