12 April 2024 in Science Advances
Histological hematoxylin and eosin–stained (H&E) tissue sections are used as the gold standard for pathologic detection of cancer, tumor margin detection, and disease diagnosis. Producing H&E sections, however, is invasive and time-consuming. While deep learning has shown promise in virtual staining of unstained tissue slides, true virtual biopsy requires staining of images taken from intact tissue. In this work, we developed a micron-accuracy coregistration method [micro-registered optical coherence tomography (OCT)] that can take a two-dimensional (2D) H&E slide and find the exact corresponding section in a 3D OCT image taken from the original fresh tissue. We trained a conditional generative adversarial network using the paired dataset and showed high-fidelity conversion of noninvasive OCT images to virtually stained H&E slices in both 2D and 3D. Applying these trained neural networks to in vivo OCT images should enable physicians to readily incorporate OCT imaging into their clinical practice, reducing the number of unnecessary biopsy procedures.
5 May 2015 in Israel Journal of Ecology and Evolution
Smell and touch convey most of the information that nocturnal rodents collect in their natural environments, each via its own complex network of muscles, receptors and neurons. Being active senses, a critical factor determining the integration of their sensations relates to the degree of their coordination. While it has been known for nearly 50 years that sniffing and whisking can be coordinated, the dynamics of such coordination and its dependency on behavioral and environmental conditions are not yet understood. Here we introduce a novel non-invasive method to track sniffing along with whisking and locomotion using high-resolution video recordings of mice, during free exploration of an open arena. Active sensing parameters in each modality showed significant dependency on exploratory modes (“Outbound”, “Exploration” and “Inbound”) and locomotion speed. Surprisingly, the correlation between sniffing and whisking was often as high as the bilateral inter-whisker correlation. Both inter-whisker and inter-modal coordination switched between distinct high-correlation and low-correlation states. The fraction of time with high-correlation states was higher in the Outbound and Exploration modes compared with the Inbound mode. Overall, these data indicate that sniffing–whisking coordination is a complex dynamic process, likely to be controlled by multiple-level inter-modal coordinated loops of motor-sensory networks.
27 May 2019 in Applied Physics Letters
Angular compounding is a technique for reducing speckle noise in optical coherence tomography that is claimed to significantly improve the signal-to-noise ratio (SNR) of images without impairing their spatial resolution. Here, we examine how focal point movements caused by optical aberrations in an angular compounding system may produce unintended spatial averaging and concomitant loss of spatial resolution. Experimentally, we accounted for such aberrations by aligning our system and measuring distortions in images and found that when the distortions were corrected, the speckle reduction by angular compounding was limited. Our theoretical analysis using Monte Carlo simulations indicates that “pure” angular compounding (i.e., with no spatial averaging) over our full numerical aperture (13° in air) can improve the SNR by not more than a factor of 1.3. Illuminating only a partial aperture cannot improve this factor compared to a spatial averaging system with equivalent loss of resolution. We conclude that speckle reduction using angular compounding is equivalent to spatial averaging. Nonetheless, angular compounding may be useful for improving images in applications where the depth of field is important. The distortions tend to be the greatest off the focal plane, and so angular compounding combined with our correction technique can reduce speckle with a minimal loss of resolution across a large depth of field.