21 September 2016 in European Spine Journal
2 May 2014 in Medical Physics
14 June 2015 in Journal of NeuroInterventional Surgery
Background: Protection of the head and eyes of the neurointerventional radiologist is a growing concern, especially after recent reports on the incidence of brain cancer among these personnel, and the revision of dose limits to the eye lens. The goal of this study was to determine typical occupational dose levels and to evaluate the efficiency of non-routine radiation protective gear (protective eyewear and cap). Experimental correlations between the dosimetric records of each measurement point and kerma area product (KAP), and between whole body doses and eye lens doses were investigated.Methods: Measurements were taken using thermoluminescent dosimeters placed in plastic bags and worn by the staff at different places. To evaluate the effective dose, whole body dosimeters (over and under the lead apron) were used.Results: The mean annual effective dose was estimated at 0.4 mSv. Annual eye lens exposure was estimated at 17 mSv when using a ceiling shield but without protective glasses. The protective glasses reduced the eye lens dose by a factor of 2.73. The mean annual dose to the brain was 12 mSv; no major reduction was observed when using the cap. The higher correlation coefficients with KAP were found for the dosimeters positioned between the eyes (R2=0.84) and above the apron, and between the eye lens (R2=0.85) and the whole body.Conclusions: Under the specific conditions of this study, the limits currently applicable were respected. If a new eye lens dose limit is introduced, our results indicate it could be difficult to comply with, without introducing additional protective eyewear.
1 January 2019 in Physica Medica
1 November 2017 in Physica Medica
1 October 2018 in Journal of Children's Orthopaedics
Purpose: Exposure to ionizing radiation is a concern for children during intraoperative imaging. We aimed to assess the radiation exposure to the paediatric patient with 2D and 3D imaging. Methods: To evaluate the radiation exposure, patient absorbed doses to the organs were measured in an anthropomorphic phantom representing a five-year-old child, using thermoluminescent dosimeters. For comparative purposes, organ doses were measured using a C-arm for one minute of fluoroscopy and one acquisition with an O-arm. The cone-beam was centred on the pelvis. Direct and scattered irradiations were measured and compared (Student's t -test). Skin entrance dose rates were also evaluated. Results: All radiation doses were expressed in µGy. Direct radiation doses of pelvic organs were between 631.22 and 1691.87 for the O-arm and between 214.08 and 737.51 for the C-arm, and were not significant (p = 0.07). Close scattered radiation on abdominal organs were between 25.11 and 114.85 for the O-arm and between 8.03 and 55.34 for the C-arm, and were not significant (p = 0.07). Far scattered radiation doses on thorax, neck and head varied from 0.86 to 6.42 for the O-arm and from 0.04 to 3.08 for the C-arm, and were significant (p = 0.02). The dose rate at the skin entrance was 328.58 µGy.s −1 for the O-arm and 1.90 with the C-arm. Conclusion: During imaging of the pelvis, absorbed doses for a 3D O-arm acquisition were higher than with one minute fluoroscopy with the C-arm. Further clinical studies comparing effective doses are needed to assess ionizing risks of the intraoperative imaging systems in children.