Marta Sans Merce

Dr. Marta Sans Merce

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Dentomaxillofacial Radiology
Verified
Journal Article
Open access
MDMarine Deleu
Marine Deleu
DDDorothea Dagassan
Dorothea Dagassan
IBIsabelle Berg
Isabelle Berg
JBJulie Bize
Julie Bize
KDKarl Dula
Karl Dula
MMMarta Sans Merce
Marta Sans Merce
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (PKA). Results: 227 answers were collected (38% of all centers). Third quartile of PKA values were obtained for five dental indications: 662 mGy cm² for wisdom tooth, 683 mGy cm² for single tooth implant treatment, 542 mGy cm² for tooth position anomalies, 569 mGy cm² for pathological dentoalveolar modifications, and 639 mGy cm² for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and PKA were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.

1 November 2016 in Journal of the American College of Radiology
Verified
Journal Article
Open access
OBOlivera Ciraj Bjelac
Olivera Ciraj Bjelac
ECEleftheria Carinou
Eleftheria Carinou
PFPaolo Ferrari
Paolo Ferrari
MGMerce Gingaume
Merce Gingaume
MMMarta Sans Merce
Marta Sans Merce
UOUna O’cOnnor
Una O’cOnnor
Occupational exposure from interventional x-ray procedures is one of the areas in which increased eye lens exposure may occur. Accurate dosimetry is an important element to investigate the correlation of observed radiation effects with radiation dose, to verify the compliance with regulatory dose limits, and to optimize radiation protection practice. The objective of this work is to review eye lens dose levels in clinical practice that may occur from the use of ionizing radiation. The use of a dedicated eye lens dosimeter is the recommended methodology; however, in practice it cannot always be easily implemented. Alternatively, the eye lens dose could be assessed from measurements of other dosimetric quantities or other indirect parameters, such as patient dose. The practical implementation of monitoring eye lens doses and the use of adequate protective equipment still remains a challenge. The use of lead glasses with a good fit to the face, appropriate lateral coverage, and/or ceiling-suspended screens is recommended in workplaces with potential high eye lens doses.

14 June 2015 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
MMMarta Sans Merce
Marta Sans Merce
AKAmine M Korchi
Amine M Korchi
LKLisa Kobzeva
Lisa Kobzeva
JDJérôme Damet
Jérôme Damet
GEGorislav Erceg
Gorislav Erceg
VPVitor Mendes Pereira
Vitor Mendes Pereira
Background: Protection of the head and eyes of the neurointerventional radiologist is a growing concern, especially after recent reports on the incidence of brain cancer among these personnel, and the revision of dose limits to the eye lens. The goal of this study was to determine typical occupational dose levels and to evaluate the efficiency of non-routine radiation protective gear (protective eyewear and cap). Experimental correlations between the dosimetric records of each measurement point and kerma area product (KAP), and between whole body doses and eye lens doses were investigated.Methods: Measurements were taken using thermoluminescent dosimeters placed in plastic bags and worn by the staff at different places. To evaluate the effective dose, whole body dosimeters (over and under the lead apron) were used.Results: The mean annual effective dose was estimated at 0.4 mSv. Annual eye lens exposure was estimated at 17 mSv when using a ceiling shield but without protective glasses. The protective glasses reduced the eye lens dose by a factor of 2.73. The mean annual dose to the brain was 12 mSv; no major reduction was observed when using the cap. The higher correlation coefficients with KAP were found for the dosimeters positioned between the eyes (R2=0.84) and above the apron, and between the eye lens (R2=0.85) and the whole body.Conclusions: Under the specific conditions of this study, the limits currently applicable were respected. If a new eye lens dose limit is introduced, our results indicate it could be difficult to comply with, without introducing additional protective eyewear.

16 May 2024 in Journal of Radiological Protection
Verified
Journal Article
Open access
LDLaura Dupont
Laura Dupont
CAChristoph Aberle
Christoph Aberle
DBDiomidis Botsikas
Diomidis Botsikas
MIMichael Ith
Michael Ith
TLThiago Viana Miranda Lima
Thiago Viana Miranda Lima
MMMarta Sans Merce
Marta Sans Merce
The aim of this study is to propose diagnostic reference levels (DRLs) values for mammography in Switzerland. For the data collection, a survey was conducted among a sufficient number of centres, including five University hospitals, several cantonal hospitals, and large private clinics, covering all linguistic regions of Switzerland to be representative of the clinical practice. The data gathered contained the mean glandular dose (MGD), the compressed breast thickness (CBT), the mammography model and the examination parameters for each acquisition. The data collected was sorted into the following categories: 2D or digital breast tomosynthesis (DBT) examination, craniocaudal (CC) or mediolateral oblique (MLO) projection, and eight categories of CBT ranging from 20 mm to 100 mm in 10 mm intervals. A total of 24 762 acquisitions were gathered in 31 centres on 36 mammography units from six manufacturers. The analysis showed that the data reflects the practice in Switzerland. The results revealed that the MGD is larger for DBT than for 2D acquisitions for the same CBT. From 20–30 mm to 90–100 mm of CBT, the 75th percentile of the MGD values obtained increased from 0.81 mGy to 2.55 mGy for 2D CC acquisitions, from 0.83 mGy to 2.96 mGy for 2D MLO acquisitions, from 1.22 mGy to 3.66 mGy for DBT CC acquisitions and from 1.33 mGy to 4.04 mGy for DBT MLO acquisitions. The results of the survey allow us to propose Swiss DRLs for mammography according to the examination type (2D/DBT), projection (CC/MLO) and CBT. The proposed values are very satisfactory in comparison with other studies.

1 June 2021 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
TSTeemu Siiskonen
Teemu Siiskonen
AGAoife Gallagher
Aoife Gallagher
OBOlivera Ciraj Bjelac
Olivera Ciraj Bjelac
LNLeos Novak
Leos Novak
MMMarta Sans Merce
Marta Sans Merce
MKMika Kortesniemi
Mika Kortesniemi
Cone beam computed tomography (CBCT) has been available since the late 1990s for use in dentistry. European legislation requires optimisation of protection and the use of diagnostic reference levels (DRLs) as well as regular quality control (QC) of the imaging devices, which is well outlined in existing international recommendations. Nevertheless, the level of application is not known. Earlier studies have indicated that few European countries have established DRLs and that patient doses (exposure parameters) have not been properly optimised. The EURADOS Working Group 12—Dosimetry in Medical Imaging undertook a survey to identify existing practices in Member States. Questionnaires were developed to identify equipment types, clinical procedures performed, and exposure settings used. The surveys were circulated to 22 countries resulting in 28 responses from 13 countries. Variations were identified in the exposure factors and in the doses delivered to patients for similar clinical indicators. Results confirm that patient doses are still not properly optimised and DRLs are largely not established. There is a need to promote the importance of performing QC testing of dental CBCT equipment and to further optimise patient exposure by establishment and use of DRLs as a part of a continuous optimisation process.

29 November 2023 in Tomography
Verified
Journal Article
Open access
PDF file
MHMarion Hamard
Marion Hamard
MMMarta Sans Merce
Marta Sans Merce
KGKarel Gorican
Karel Gorican
PPPierre-Alexandre POLETTI
Pierre-Alexandre POLETTI
ANAngeliki Neroladaki
Angeliki Neroladaki
SBSana Boudabbous
Sana Boudabbous
Osteoarthritis (OA) is a prevalent disease and the leading cause of pain, disability, and quality of life deterioration. Our study sought to evaluate the image quality and dose of cone-beam computed tomography arthrography (CBCT-A) and compare them to digital radiography (DR) for OA diagnoses. Overall, 32 cases of CBCT-A and DR with OA met the inclusion criteria and were prospectively analyzed. The Kellgren and Lawrence classification (KLC) stage, sclerosis, osteophytes, erosions, and mean joint width (MJW) were compared between CBCT-A and DR. Image quality was excellent in all CBCT-A cases, with excellent inter-observer agreement. OA under-classification was noticed with DR for MJW (p = 0.02), osteophyte detection (<0.0001), and KLC (p < 0.0001). The Hounsfield Unit (HU) values obtained for the cone-beam computed tomography CBCT did not correspond to the values for multi-detector computed tomography (MDCT), with a greater mean deviation obtained with the MDCT HU for Modeled Based Iterative Reconstruction 1st (MBIR1) than for the 2nd generation (MBIR2). CBCT-A has been found to be more reliable for OA diagnosis than DR as revealed by our results using a three-point rating scale for the qualitative image analysis, with higher quality and an acceptable dose. Moreover, the use of this imaging technique permits the preoperative assessment of extremities in an OA diagnosis, with the upright position and bone microarchitecture analysis being two other advantages of CBCT-A.