1 September 2007 in Chinese Physics
5 December 2022 in High Voltage
The physical mechanism of leader formation and development is not well understood. In this study, we present experimental and simulation results obtained with a 10 m long air gap discharge. A 10 m outdoor discharge experiment is carried out to obtain the current, voltage, and optical image during the leader discharge process. Four different impulse voltages were applied to the rod‐plane gap. The measured current is used as an input for a plasma model, then the temperature and electric field could be calculated. The simulation results show that the temperature of the streamer stem during the dark period may exceed 2000 K. In addition, the critical charge required for leader initiation can be as low as 0.27 μC for a 10 m air gap. The channel temperature is relatively stable in the process of leader development, which is maintained at about 4500 K. The electron density is about 0.5–3 × 10 20 m −3 , and the discharge channel conductivity fluctuates in the range of 1–10 S/m for the leader current between 1 and 2 A. A long dark period is tended to be associated with a higher injected charge by the first streamer. It is inferred that the voltage increments during the dark period play an important role in promoting streamer‐to‐leader transition, except for temperature and the injected charge.
27 August 2015 in Journal of Applied Physics
The control of electron energy probability functions (EEPFs) in low pressure partially ionized plasmas is typically accomplished through the format of the applied power. For example, through the use of pulse power, the EEPF can be modulated to produce shapes not possible under continuous wave excitation. This technique uses internal control. In this paper, we discuss a method for external control of EEPFs by transport of electrons between separately powered inductively coupled plasmas (ICPs). The reactor incorporates dual ICP sources (main and auxiliary) in a tandem geometry whose plasma volumes are separated by a grid. The auxiliary ICP is continuously powered while the main ICP is pulsed. Langmuir probe measurements of the EEPFs during the afterglow of the main ICP suggests that transport of hot electrons from the auxiliary plasma provided what is effectively an external source of energetic electrons. The tail of the EEPF and bulk electron temperature were then elevated in the afterglow of the main ICP by this external source of power. Results from a computer simulation for the evolution of the EEPFs concur with measured trends.