Nofrizalidris Darlis

Nofrizalidris Darlis

Auto-generated profile, based on publicly available information

Nofrizalidris Darlis

Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia (UTHM), Batu Pahat, Malaysia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2017 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
NDNofrizalidris Darlis
Nofrizalidris Darlis
KOKahar Osman
Kahar Osman
MPMuhamad Hasbullah Padzillah
Muhamad Hasbullah Padzillah
JDJeswant Dillon
Jeswant Dillon
AKAhmad Zahran Md Khudzari
Ahmad Zahran Md Khudzari

2 March 2022 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
AKAli Kamil Kareem
Ali Kamil Kareem
MGMustafa M. Gabir
Mustafa M. Gabir
IAInas R. Ali
Inas R. Ali
AIAl Emran ISMAIL
Al Emran ISMAIL
ITIshkrizat Taib
Ishkrizat Taib
OAOmar M. Almoayed
Omar M. Almoayed
The increasing number of studies on the behaviour of stent placement in recent decades provides a clear understanding of peripheral artery disease (PAD). The severe mechanical loads (axial tension and compression, bending, radial compression and torsion) deformation of the femoropopliteal artery (FPA) is responsible for the highest failure rate of permanent nickel-titanium (Nitinol) stents. Therefore, the purpose of this article is to review research papers that examined the deformation of the natural load environment of FPA, the properties of Nitinol and mechanical considerations. In conclusion, a better understanding of mechanical behaviour for FPA Nitinol stents contributes to increased mechanical performance and fatigue-life.

14 August 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
MPMuhammad Sufyan Amir Paisal
Muhammad Sufyan Amir Paisal
SASyed Fadhil Syed Adnan
Syed Fadhil Syed Adnan
ITIshkrizat Taib
Ishkrizat Taib
AIAl Emran ISMAIL
Al Emran ISMAIL
MAMohammad Kamil Abdullah
Mohammad Kamil Abdullah
NDNofrizalidris Darlis
Nofrizalidris Darlis
Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

29 September 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
MPMuhammad Sufyan Amir Paisal
Muhammad Sufyan Amir Paisal
MWMuhamad Azmi Wahab
Muhamad Azmi Wahab
ITIshkrizat Taib
Ishkrizat Taib
NINorasikin Mat Isa
Norasikin Mat Isa
YRYahaya Ramli
Yahaya Ramli
NNNormayati Nordin
Normayati Nordin
Meniere's disease is a rare disorder that affects the inner ear which might be more severe if not treated. This is due to fluctuating pressure of the fluid in the endolymphatic sac and dysfunction of cochlea which causing the stretching of vestibular membrane. However, the pattern of the flow recirculation in endolymphatic region is still not fully understood. Thus, this study aims to investigate the correlation between the increasing volume of endolymphatic fluid and flow characteristics such as velocity, pressure and wall shear stress. Three dimensional model of simplified endolymphatic region is modeled using computer aided design (CAD) software and simulated using computational fluid dynamic (CFD) software. There are three different models are investigated; normal (N) model, Meniere's disease model with less severity (M1) and Meniere's disease model with high severity (M2). From the observed, the pressure drop between inlet and outlet of inner ear becomes decreases as the outlet pressure along with endolymphatic volume increases. However, constant flow rate imposed at the inlet of endolymphatic showing the lowest velocity. Flow recirculation near to endolymphatic region is occurred as the volume in endolympathic increases. Overall, high velocity is monitored near to cochlear duct, ductus reuniens and endolymphatic duct. Hence, these areas show high distributions of wall shear stress (WSS) that indicating a high probability of endolymphatic wall membrane dilation. Thus, more severe conditions of Meniere's disease, more complex of flow characteristic is occurred. This phenomenon presenting high probability of rupture is predicted at the certain area in the anatomy of vestibular system.

29 September 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
STSiti A Thomas
Siti A Thomas
SEShirly Empaling
Shirly Empaling
NDNofrizalidris Darlis
Nofrizalidris Darlis
KOKahar Osman
Kahar Osman
JDJeswant Dillon
Jeswant Dillon
AKAhmad Zahran Md Khudzari
Ahmad Zahran Md Khudzari
Aortic cannulation has been the gold standard for maintaining cardiovascular function during open heart surgery while being connected onto the heart lung machine. These cannulation produces high velocity outflow which may lead to adverse effect on patient condition, especially sandblasting effect on aorta wall and blood cells damage. This paper reports a novel design that was able to decrease high velocity outflow. There were three design factors of that was investigated. The design factors consist of the cannula type, the flow rate, and the cannula tip design which result in 12 variations. The cannulae type used were the spiral flow inducing cannula and the standard cannula. The flow rates are varied from three to five litres per minute (lpm). Parameters for each cannula variation included maximum velocity within the aorta, pressure drop, wall shear stress (WSS) area exceeding 15 Pa, and impinging velocity on the aorta wall were evaluated. Based on the result, spiral flow inducing cannulae is proposed as a better alternatives due to its ability to reduce outflow velocity. Meanwhile, the pressure drop of all variations are less than the limit of 100 mmHg, although standard cannulae yielded better result. All cannulae show low reading of wall shear stress which decrease the possibilities for atherogenesis formation. In conclusion, as far as velocity is concerned, spiral flow is better compared to standard flow across all cannulae variations.