Ishkrizat Taib

Ishkrizat Taib

Auto-generated profile, based on publicly available information

Ishkrizat Taib

Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia (UTHM), Batu Pahat, Malaysia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2022 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
AKAli Kamil Kareem
Ali Kamil Kareem
MGMustafa M. Gabir
Mustafa M. Gabir
IAInas R. Ali
Inas R. Ali
AIAl Emran ISMAIL
Al Emran ISMAIL
ITIshkrizat Taib
Ishkrizat Taib
OAOmar M. Almoayed
Omar M. Almoayed
The increasing number of studies on the behaviour of stent placement in recent decades provides a clear understanding of peripheral artery disease (PAD). The severe mechanical loads (axial tension and compression, bending, radial compression and torsion) deformation of the femoropopliteal artery (FPA) is responsible for the highest failure rate of permanent nickel-titanium (Nitinol) stents. Therefore, the purpose of this article is to review research papers that examined the deformation of the natural load environment of FPA, the properties of Nitinol and mechanical considerations. In conclusion, a better understanding of mechanical behaviour for FPA Nitinol stents contributes to increased mechanical performance and fatigue-life.

14 August 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
MPMuhammad Sufyan Amir Paisal
Muhammad Sufyan Amir Paisal
SASyed Fadhil Syed Adnan
Syed Fadhil Syed Adnan
ITIshkrizat Taib
Ishkrizat Taib
AIAl Emran ISMAIL
Al Emran ISMAIL
MAMohammad Kamil Abdullah
Mohammad Kamil Abdullah
NDNofrizalidris Darlis
Nofrizalidris Darlis
Femoropopiteal artery stenting is a common procedure suggested by medical expert especially for patient who is diagnosed with severe stenosis. Many researchers reported that the growth of stenosis is significantly related to the geometry of stent strut configuration. The different shapes of stent geometry are presenting the different flow pattern and re-circulation in stented femoropopliteal artery. The blood flow characteristics near to the stent geometry are predicted for the possibility of thrombosis and atherosclerosis to be formed as well as increase the growth of stenosis. Thus, this study aims to determine the flow characteristic near to stent strut configuration based on different hemodynamic parameters. Three dimensional models of stent and simplified femoropopliteal artery are modelled using computer aided design (CAD) software. Three different models of stent shapes; hexagon, circle and rectangle are simulated using computational fluid dynamic (CFD) method. Then, parametric study is implemented to predict the performance of stent due to hemodynamic differences. The hemodynamic parameters considered are pressure, velocity, low wall shear stress (WSSlow) and wall shear stress (WSS). From the observation, flow re-circulation has been formed for all simulated stent models which the proximal region shown the severe vortices. However, rectangular shape of stent strut (Type P3) shows the lowest WSSlow and the highest WSS between the range of 4 dyne/cm2 and 70 dyne/cm2. Stent Type P3 also shows the best hemodynamic stent performance as compare to others. In conclusion, Type P3 has a favourable result in hemodynamic stent performance that predicted less probability of thrombosis and atherosclerosis to be formed as well as reduces the growth of restenosis.

21 December 2020 in CFD Letters
Verified
Journal Article
Open access
PDF file
MRMuhammad Faqhrurrazi Abd Rahman
Muhammad Faqhrurrazi Abd Rahman
NANor Zelawati Asmuin
Nor Zelawati Asmuin
ITIshkrizat Taib
Ishkrizat Taib
JNJuwaidi Nazar
Juwaidi Nazar
RKRiyadhthusollehan Khairulfuaad
Riyadhthusollehan Khairulfuaad
Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory coronavirus-2 syndrome (SARS-CoV-2) were first reported by officials in Wuhan City, China, in December 2019. COVID-19 patients have a symptom of respiratory pneumonia diseases which have difficulties in breathing normally. Previously, the nebulizer machine commonly used to treat respiratory pneumonia diseases. However, the usage for this machine was not suggested during this COVID-19 period because the virus will be spread off easily. To overcome these shortcomings, the uses of Metered-Dose Inhaler (MDI) with MDI disposable inhaler spacer is preferable. Besides, it had been known that the used of MDI disposable inhaler spacer helps to increase the uptaking of the drug into the lung. Besides that, the high demand for the MDI Disposable Inhaler Spacer in the hospital, causing a shortage of supply in Malaysia. Thus, this study aims to produce a new design of this spacer to full fill the market need. This new design of MDI Disposable Inhaler Spacer (AeroCup) was designed by using Solid Work 2018. Then, the parameters for flow characteristic such as particle velocity magnitude, velocity, Eddy viscosity, turbulence Eddy dissipation and turbulence kinetic energy (TKE) was successfully characterized and compared with commercial design A using ANSYS Fluent Version 19.2. The result showed that new design (AeroCup) had the desired characteristic, which was almost similar to commercial design A. This study can provide a piece of information to produce the low-cost metered-dose inhaler (MDI) disposable inhaler spacer to enlighten the burden shouldered by front liners, especially during the pandemic and also can scale-up the economic viability.

5 December 2021 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
RKRiyadhthusollehan Khairulfuaad
Riyadhthusollehan Khairulfuaad
NANorzelawati Asmuin
Norzelawati Asmuin
ITIshkrizat Taib
Ishkrizat Taib
This study aims to explore the knowledge on fluid flow properties of the aqueous humour (AH), specifically on the anterior segment (AS) of the human eye for a medical condition called Glaucoma. The research objectives are to study on fluid flow characteristics of velocity and pressure of the AH on the AS of the eye using enlarged 3D printed model and computational analysis, and also to analyse the suitability of the 3D generated anterior AS in fluid flow analysis application on particle image velocimetry (PIV). Using polyvinyl alcohol (PVA) as a water-soluble 3D printing filament, a 3D model of the AS of the human eye was generated with SolidWorks 2018 and printed using Creality Ender 3. This printed model serves as the pattern for silicon rubber mould production using vacuum casting process. Analysis of AH flow hydrodynamics are conducted with computational analysis using ANSYS Workbench 19.2. Key findings support that use of PVA material suite the creation of specific shapes and patterns for 3D modelling applications alike, and silicon rubber moulding creates a non-reactive and long-lasting mould for PIV applications. Computational analysis findings support the use of the generated model for PIV applications. Overall, the study successfully supports the use of 3D printed model for PIV application and future work that can be induced include direct experimentation of the mould with PIV.

25 December 2021 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
NSNor Adrian Nor Salim
Nor Adrian Nor Salim
NANorzelawati Asmuin
Norzelawati Asmuin
AHAzian Hariri
Azian Hariri
MSM. Farid Sies
M. Farid Sies
HZHanis Zakaria
Hanis Zakaria
AAAHMAD MUBARAK TAJUL ARIFIN
AHMAD MUBARAK TAJUL ARIFIN
A Water-mist spray system in several heavy-duty kitchen hood canopies is installed to efficiently control the high heat loads and grease emissions produced from the cooking process and for safety purposes. The main purpose of this study is to reduce water consumption by introducing the water-mist recirculation system to replace the current method water-mist system since it is working as water loss. A standard ASTM 2519 and UL 1046 full-scaled experiment is developed in the laboratory. An existing Halton Europe/Asian water-mist operating system is adopted in this study. Twelve (12) cycles (at 24 hours of water-mist activation) have been studied to determine the maximum water-mist activation cycle. The data are collected at two (2) hours water-mist activation at every water-mist recirculation cycle. The water-mist spray fluids viscosity is 0.7 cP from fresh water until the 4th cycle (8 hours water-mist spray) and increase 14.29% (0.8 cP) at the 5th cycle to the 12th cycle. On average, the difference in gas emissions percentage for CO concentration between fresh water until the 4th cycle is 10.81 – 18.92% while the CO2 concentration is 12.33 – 18.22%. On average, the difference in cooling effects percentage for ducting temperature between fresh water until the 4th cycle is 5.55% while the hood temperature is 2.33%. From the study, the water-mist recirculation system could save up to 611,667 litres per year and 466,798.5 litres per year water for all U.S, European, and Asian kitchen hood designs per hood length. By adopting the new water-mist recirculation system to the current water-mist kitchen hood, the water operational cost for water successfully reduced to RM 4,889.63 per year and RM 6,977.86 per year for U.S design and European or Asian design per hood length respectively. The water-mist recirculation system has great potential to improve the current water-mist system for the commercial kitchen hood.