Xinyan Yang

Xinyan Yang

Auto-generated profile, based on publicly available information

Xinyan Yang

Anhui Province Key Laboratory for Control and Applications of Optoelectronic Information Materials, Department of Physics, Anhui Normal University, Wuhu, Anhui 241000, P.R. China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
XYXinyan Yang
Xinyan Yang
RYRongxing Yi
Rongxing Yi
XLXiangyou Li
Xiangyou Li
ZCZhifeng Cui
Zhifeng Cui
YLYong Feng Lu
Yong Feng Lu
WHWanxia Huang
Wanxia Huang
To improve the quantitative analysis accuracy of an aqueous solution using surface-enhanced laser-induced breakdown spectroscopy (SENLIBS), the filter paper was used as a transmission medium by placing it onto the surface of a metallic substrate to make the microdroplet spreading more uniform in a fixed region of the substrate surface. The trace elements (Cu, Pb, Cd, and Cr) in an aqueous solution were detected successfully using this method. The results showed that the sample preparation repeatability of SENLIBS was noticeably improved with the aid of filter paper. Moreover, the limit of detection (LoD) values was similar to those without filter paper. Furthermore, the R2 values were improved from 0.6192~0.9321 to 0.9481~0.9766, the RMSECV values were decreased from 0.53~1.95 μg/mL to 0.33~1.06 μg/mL, and the average relative error (ARE) values were decreased from 8.96~22.31% to 4.28~14.37% with the aid of filter paper. This demonstrated that the use of filter paper could improve the quantitative analysis accuracy of SENLIBS by increasing the sample preparation repeatability.

17 June 2020 in Frontiers in Physics
Verified
Journal Article
Open access
XYXinyan Yang
Xinyan Yang
XLXiangyou Li
Xiangyou Li
ZCZhifeng Cui
Zhifeng Cui
GYGuanxin Yao
Guanxin Yao
ZZZhengxian Zhou
Zhengxian Zhou
KLKuanguo Li
Kuanguo Li
To improve the detection sensitivity of aqueous solution using surface-enhanced laser-induced breakdown spectroscopy (SENLIBS), the number of sample preparation in a fixed point was increased. The trace elements (Cu, Pb, Cd, and Cr) in an aqueous solution were detected successfully using this method. The results showed that the spectral intensity was strengthened. The limit of detection (LoD) values were reduced from 0.034~0.058 to 0.019~0.033 μg/mL by increasing number of repeating sample preparation. This demonstrated that quantitative analysis sensitivity of SENLIBS could be improved by increasing the sample preparation repeatability.

23 August 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
XYXinyan Yang
Xinyan Yang
XLXiangyou Li
Xiangyou Li
ZCZhifeng Cui
Zhifeng Cui
ZHZhongqi Hao
Zhongqi Hao
YLYong Feng Lu
Yong Feng Lu
XWXiaoli Wang
Xiaoli Wang
In this study, chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy (CR-SENLIBS) was introduced for detecting the trace chromium (Cr) element in an aqueous solution, which could use chemical replacement to change the sample from liquid to solid. In order to illustrate the analytical-performance of the CR-SENLIBS, the direct analysis of the liquid surface by LIBS (LSLIBS) was investigated for comparison. The results show that the spectral intensity of Cr I 357.86 nm, plasma lifetime, and spectral stability were improved. Moreover, the limit of detection of Cr I 357.86 nm was 0.018 μg/mL, which was lower than 1.814 μg/mL for LSLIBS. Furthermore, the accuracy and precision were improved more than 60% and 80%, respectively; for example, the root-mean-square error of cross-validation was improved from 1.09 to 0.75 μg/mL, and the average relative standard deviation of the predicted concentration of Cr was reduced from 22.89% to 4.53% by using CR-SENLIBS. These results suggest that CR-SENLIBS has good analytical-performance, which exhibits great potential in water quality monitoring.

2 January 2024 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
XYXinyan Yang
Xinyan Yang
XWXin Wang
Xin Wang
DLDongdong Li
Dongdong Li
XZXu Zhang
Xu Zhang
KLKuohu Li
Kuohu Li
XZXianfeng Zheng
Xianfeng Zheng
For analyzing the phosphorus (P) element in water, a liquid aerosol is used as a sampling method of laser-induced breakdown spectroscopy (LIBS). To further improve the detection performance of liquid aerosol-LIBS, the effect of liquid aerosol temperature on the qualitative and quantitative analysis was investigated. With increasing the liquid aerosol temperature, the emission intensity of P increased with the temperature; the threshold energy density (Eth) of P I 213.618 nm decreased from 9.98 to 6.62 J cm−2, and the optimal laser energy density reduced from 26.00 to 18.70 J cm−2. In addition, the LoD of P decreased from 5.22 to 1.81 ppm, and the average relative standard deviation (ARSD) of the intensity of P I 213.618 nm was similar. Furthermore, the R2, the average relative error (ARE), and the root mean square error of cross validation (RMSECV) were improved from 0.9926 to 0.9964, 8.93 to 5.95%, and 4.85 to 2.91 ppm. The results indicate that liquid aerosol temperature affects the sensitivity, LoD, and accuracy of liquid aerosol-LIBS for the analysis of P in water.

1 February 2023 in Journal of Laser Applications
Verified
Journal Article
Closed access
PDF file
CLChao Lv
Chao Lv
NZNing Zhang
Ning Zhang
ZLZhanjian Lin
Zhanjian Lin
TOTianxue Ou
Tianxue Ou
Jiaming LiJiaming Li
Jiaming Li
QZQingmao Zhang
Qingmao Zhang
Fiber lasers are characterized by high efficiency, good beam quality, and high reliability and are widely used in industries. In addition, the high repetition frequency of fiber lasers can increase the analytical efficiency greatly. In this paper, a nanosecond fiber laser was introduced to be the ablation source in laser-induced breakdown spectroscopy (LIBS) for determining copper, magnesium, and manganese in aluminum alloys. Because of the high repetition frequency of the fiber laser, the conventional delay-acquisition strategy was unavailable. Discrete wavelet transform (DWT) was used to mitigate the interference of the Bremsstrahlung background. Standard calibration and internal calibration methods were also compared for quantitative analyses. The results demonstrated that the combination of DWT and internal calibration effectively improved the analytical accuracy. After optimization, the R2s of the FL-LIBS system for Cu, Mg, and Mn were 0.9897, 0.9964, and 0.9979, respectively; the root mean squared error of cross validation was 0.0414, 0.0462, and 0.031 wt. %, respectively. This study provides a convenient method for the rapid elemental analysis of aluminum alloys.

25 April 2024 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
ZZZhenmei Zhang
Zhenmei Zhang
ZWZhicheng Wang
Zhicheng Wang
QWQiaolin Wang
Qiaolin Wang
XMXiaokang Ma
Xiaokang Ma
ZWZhixie Wang
Zhixie Wang
XZXianfeng Zheng
Xianfeng Zheng
In this work, the threshold photoionization cross sections from the excited states of lutetium and ytterbium atoms were investigated by the laser pump–probe scheme under the condition of saturated resonant excitation. We obtained the resonance enhanced multiphoton ionization spectra of the lutetium and ytterbium atoms of the lanthanide metals in the range of 307.50–312.50 nm and 265.00–269.00 nm, respectively; the photoionization cross sections of the 5d6s(1D)6p(2D05/2) and 5d6s(3D)6p(2P01/2) states of lutetium and the 4f13(2F0)5d6s2(J = 1) states of ytterbium above threshold regions (0.4–1.6 eV) were measured, and measured values ranged from 2.3 ± 0.2 to 17.7 ± 1.5 Mb.