Objective: Evaluate the inter and intra-observer reliability of Nash and Moe’s grades, used to assess patients diagnosed with Adolescent Idiopathic Scoliosis (AIS). Methodology: Forty-seven representative x-rays of patients with AIS were randomly selected to evaluate the apical vertebral rotation (AVR) using Nash and Moe’s grades. The evaluation of the AVR was made independently in two distinct moments by two observers. The inclusion criteria in the study were a patient diagnosed with AIS and an orthostasis radiography with a good-quality image. An agreement study between the evaluations and the inter and intraobserver’s reliability was determined using Kappa’s statistics with a confidence interval of 95%. Results: The interobservers’ Kappa’s value in the first evaluation was 0,44 (CI 95%; 0,22-0,66) and 0,37 (CI 95%; 0,17-0,56) in the second. In the intraobservers’ evaluations, the Kappa’s value for examiner 1 was 0,61 (CI 95%; 0,40-0,81) and 0,46 (CI 95%; 0,22-0,70) for examiner 2. Conclusion: This study’s results demonstrated that Nash and Moe’s grades are unreliable for evaluating vertebral rotation in patients with AIS. Level of Evidence III; A Cross-Sectional Study.
Objective To evaluate the immediate correction capacity of the Wood-Chêneau-Rigo brace (WCR), produced using digital technological resources and robotic engineering, in primary and secondary curves of adolescent idiopathic scoliosis (AIS). Methods A retrospective study was conducted of 138 patients with a diagnosis of AIS and who received a WCR brace from a laboratory that makes orthoses and orthopedic prostheses between 2019 and 2021. These individuals were submitted to an independent analysis of the radiographic parameters by a single researcher, the main outcome of which was the standardized measurement of the main and secondary curves using the Cobb method. The radiographs analyzed were performed in orthostasis before and immediately after the adaptation of the brace on the patient. The correction capacity was calculated as the ratio of the difference between the pre- and post-brace curves to the pre-brace curve. Results The mean correction with the WCR was 48.4% for the main curve and 41.0% for the secondary curve. The level of correction of the main curve was significantly higher in patients with a main curve with the apex of convexity in the thoracolumbar region (p = 0.004), especially in the left thoracolumbar region (p = 0.010); curves of magnitude between 10º and 24.9º (p <0.001); and curves classified as simple (p <0.001). Conclusion The use of the WCR, which is produced using modern technological resources, was effective in the immediate correction of AIS. Long-term studies on this new modality of conservative scoliosis treatment are necessary. Level of evidence III; Retrospective study.
Objective: To evaluate the axial correction capacity of the 3D brace in treating Adolescent Idiopathic Scoliosis (AIS). Methods: A retrospective study was carried out with 61 patients with AIS who obtained the 3D brace, between 2019 and 2022, in a laboratory that manufactures orthotics and orthopedic prostheses. These individuals underwent independent analysis of radiographic parameters by evaluating vertebral rotation using the Nash and Moe classification. The analyzed radiographs were taken in orthostasis before and after treatment with the 3D vest. Patients were divided into groups I and II-IV according to the Nash and Moe radiographic classification. Corrective capacity was estimated by assessing the degree of vertebral rotation before and after treatment. Results: Of the 61 patients evaluated, 36 (59%) had Nash and Moe grade I, and 25 patients grade II-IV before treatment. After treatment, 13 (21%) had grade II-IV, and 48 had grade I. Of the patients categorized as II-IV, 64% had improvement in the rotational profile. None clinical studies or radiographic parameter was associated with a change in rotational profile other than brace use (p=0.012). Conclusion: In the studied sample, treatment with the 3D vest promoted a change in vertebral rotation according to the Nash and Moe classification. The majority showed improvement in this parameter of evaluation of treatment of AIS. Level of Evidence III; Retrospective Study.
Introduction: This study aims to evaluate the safety of using the cortical path screw with transfixation of the second cortical bone in relation to the vascular structures. Methods: This retrospective observational study (level of evidence: III, study of non-consecutive patients) analyzed data from the medical records of patients who underwent computed angiotomography scans of the abdomen at Hospital Mater Dei, measuring, in millimeters, the distance between the point of the lumbar vertebra considered the anatomical reference for the transfixation of the second cortical bone and the vascular structures adjacent to the spine (abdominal aorta, inferior vena cava, iliac vessels, segmental lumbar arteries). Results: Forty-eight patients were evaluated, with a mean age of 60 years (±8 years, 41-75), of whom 52% were male and 48% female. The measurements obtained between the pre-vertebral vessels and the possible screw exit points did not demonstrate contact in any of the vertebrae studied. Conclusions: The measurements obtained suggest the safety of using the cortical path screw transfixing the second cortical bone. Knowing the position of the vessels is essential to reduce intra- and postoperative complications related to spinal instrumentation. Level of evidence III; Study of non-consecutive patients.
Objective Morphometric study of the positioning of the cortical trajectory pedicle screw in the lumbar spine of Brazilian patients of different sexes and ages, through the use of computed tomography images, in order to obtain more reliable data about cortical screw insertion and the variations observed, providing assistance for a safer, more effective approach with fewer complications. Methods Selection of 100 patients from a database, alternating by sex, measuring the length, diameter, cephalic angulation, and lateral angulation of the vertebrae from L1 to L5. Results Statistically significant measurements were obtained for the four different parameters in relation to sex. The mean age was 56, with a minimum of 20 and a maximum of 87 years. The L4 and L5 screws showed a reduction in relation to the other levels, while the width showed a progressive increase starting at L3. Lateral angulation was the parameter with the least variation among the levels, while there was greater variation and a reduction from L4 to L5 in cephalic angulation. Conclusion Statistically significant results were obtained for length, diameter, lateral and cephalic angulation. Sex was a significant factor in spine surgery instrumentation using the cortical trajectory pedicle screw technique. Level of evidence I; Diagnostic study (investigation of an examination for diagnosis).