Alexander Jaffray

Alexander Jaffray

Auto-generated profile, based on publicly available information

Alexander Jaffray

Department of Physics and Astronomy, The University of British Columbia, Vancouver, Canada

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
JOJ.M. Ospel
J.M. Ospel
AJA. Jaffray
A. Jaffray
VSV. Schulze-Zachau
V. Schulze-Zachau
SKSebastian Kozerke
Sebastian Kozerke
CFC. Federau
C. Federau
BACKGROUND AND PURPOSE: Infarct volume in acute ischemic stroke is an important prognostic marker and determines endovascular treatment decisions. This study evaluates the magnitude and potential clinical impact of the error related to partial volume effects in infarct volume measurement on diffusion-weighted MR imaging in acute stroke and explores how increasing spatial resolution could reduce this error. MATERIALS AND METHODS: Diffusion-weighted imaging of 393 patients with acute stroke, of whom 56 had anterior circulation large-vessel occlusion, was coregistered to standard space. Lesion boundaries were manually segmented. A 3D lesion-volume model was resampled for voxel sizes from 4 × 4 × 8 to 1 × 1 × 2 mm, and the surface-volume, corresponding to the partial volume error, was calculated. The number of cases with anterior circulation large-vessel occlusion, in which the endovascular therapy core threshold of 70 mL was contained within the margin of error, was calculated as a function of imaging resolution. RESULTS: The mean infarct core volume was 27.2 ± 49.9 mL. The mean surface volume was 14.7 ± 20.8 mL for 2 × 2 × 4 mm resolution and 7.4 ± 10.7 mL for 1 × 1 × 2 mm resolution. With a resolution of 2 × 2 × 4 mm, 70 mL was contained within the margin of error in 7/56 cases (12.5%) with large-vessel occlusion, while with a 1 × 1 × 2 mm voxel size, the margin of error was 3/56 (5%). The lesion-volume range of potentially misclassified lesions dropped from 46.5–94.1 mL for a 2 × 2 × 4 mm resolution to 64.4–80.1 mL for a 1 × 1 × 2 mm resolution. CONCLUSIONS: Partial volume effect is an important source of error in infarct volume measurement in acute stroke. Increasing spatial resolution substantially decreases the mean error. Standard use of high-resolution DWI should be considered to increase the reliability of infarct volume measurements.

4 March 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
LBLaura Beghini
Laura Beghini
SBSilvan Büeler
Silvan Büeler
MLMartina D. Liechti
Martina D. Liechti
AJAlexander Jaffray
Alexander Jaffray
GDGergely David
Gergely David
SVS. Johanna Vannesjo
S. Johanna Vannesjo

1 November 2025 in Radiology
Verified
Journal Article
Closed access
CGChristina Graf
Christina Graf
AJAlexander Jaffray
Alexander Jaffray
ARArmin Rund
Armin Rund
SSStefan Steinerberger
Stefan Steinerberger
DLDavid K. B. Li
David K. B. Li
ARAlexander Rauscher
Alexander Rauscher
Robust inversion in fluid-attenuated inversion recovery reduced artifacts in brain MRI that mimic hyperintense white matter lesions.

2 May 2024 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
AJAlexander Jaffray
Alexander Jaffray
ZWZhe Wu
Zhe Wu
SVS. Johanna Vannesjo
S. Johanna Vannesjo
KUKâmil Uludağ
Kâmil Uludağ
LKLars Kasper
Lars Kasper
Magnetic Resonance Imaging (MRI) acquires data in the frequency domain (k-space), with the sampling pattern traversed by a path known as the k-space trajectory. It is desirable to implement MRI data sampling using k-space trajectories with high acquisition efficiency (i.e., a fast coverage of k-space). Traditional Cartesian MRI traverses k-space by acquiring individual lines of the k-space, each requiring an excitation, a phase-encoding step, and a short readout gradient. However, it is possible to traverse k-space with an arbitrary trajectory, achieved by a long sequence of readout gradients, thus presenting the opportunity to acquire more sampling points per excitation. Spiral trajectories are a popular and efficient method for traversing k-space with a long readout, as well as classical echo-planar imaging (EPI) trajectories. Non-Cartesian trajectories, such as spiral trajectories, yield significant reductions in the number of excitations required for the acquisition of an image, thus offering considerable acceleration and improvements in signal-to-noise ratio (SNR) per unit time at the cost of reconstruction complexity. These improvements are particularly beneficial in diffusion MRI due to sequence timing constraints (Lee et al., 2021).

16 January 2026 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
AJAlexander Jaffray
Alexander Jaffray
CGChristina Graf
Christina Graf
ARArmin Rund
Armin Rund
SSStefan Steinerberger
Stefan Steinerberger
ATAnthony Traboulsee
Anthony Traboulsee
ARAlexander Rauscher
Alexander Rauscher
BACKGROUND AND PURPOSE: Double inversion recovery (DIR) is an MRI technique in which two types of tissue are suppressed, usually cerebrospinal fluid (CSF) and white matter (WM). The suppression is achieved with two inversion pulses prior to the acquisition of the imaging data. In the presence of strong inhomogeneities in the static magnetic field B0 and/or the radiofrequency (RF) field, inversion may be inadequate, resulting in bright signal in tissues that should have been suppressed. The purpose of this work was to develop a DIR scan with inversion pulses that are robust against inhomogeneities in the B0 and RF field. MATERIALS AND METHODS: In this prospective study, the DIR sequence was equipped with inversion pulses designed with optimal control. Robustness against field inhomogeneities was incorporated into the cost functional for pulse optimization. DIR and controlled DIR (C-DIR) MRI images were acquired at 3T in 14 participants (9 male, age=36.1±11.5 years) enrolled between October 2024 to August 2025 from a single academic medical center: nine healthy; two with relapsing-remitting multiple sclerosis; one with persistent concussion symptoms; two with asymptomatic white matter hyperintensities. Suppression of CSF, presence of artifacts, and visibility of multiple sclerosis lesions and white matter hyperintensities were independently assessed visually by a radiologist. In eight healthy volunteers, means and SDs were computed for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), with significance evaluated using a Student’s t-test. RESULTS: C-DIR exhibits improved inversion in the presence of inhomogeneities in the B0 and the radiofrequency field, resulting in the removal of artifactual signal. CNR increases ranged from 27% between gray matter and CSF (p<.001) to 102% between the brainstem and adjacent CSF (p<0.001). SNR in the cortical gray matter was 10.74±1.48 in DIR and 11.68±2.21 in C-DIR (p=.07). CONCLUSIONS: Inversion with a robust RF pulse improves the quality of DIR, demonstrating artifact reduction and improved CNR.

6 May 2026 in Nature Communications
Verified
Journal Article
Open access
PDF file
CGChristina Graf
Christina Graf
AJAlexander Jaffray
Alexander Jaffray
ARArmin Rund
Armin Rund
SSStefan Steinerberger
Stefan Steinerberger
DLDavid K. B. Li
David K. B. Li
ARAlexander Rauscher
Alexander Rauscher