Pablo Borrelli

Pablo Borrelli

Auto-generated profile, based on publicly available information

Pablo Borrelli

Department of Clinical Physiology, Sahlgrenska University Hospital, Blå Stråket 5, 41345, Gothenburg, Sweden

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2021 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
PBPablo Borrelli
Pablo Borrelli
RKReza Kaboteh
Reza Kaboteh
OEOlof Enqvist
Olof Enqvist
JUJohannes Ulén
Johannes Ulén
ETElin Trägårdh
Elin Trägårdh
LELars Edenbrandt
Lars Edenbrandt
Background: Body composition is associated with survival outcome in oncological patients, but it is not routinely calculated. Manual segmentation of subcutaneous adipose tissue (SAT) and muscle is time-consuming and therefore limited to a single CT slice. Our goal was to develop an artificial-intelligence (AI)-based method for automated quantification of three-dimensional SAT and muscle volumes from CT images. Methods: Ethical approvals from Gothenburg and Lund Universities were obtained. Convolutional neural networks were trained to segment SAT and muscle using manual segmentations on CT images from a training group of 50 patients. The method was applied to a separate test group of 74 cancer patients, who had two CT studies each with a median interval between the studies of 3 days. Manual segmentations in a single CT slice were used for comparison. The accuracy was measured as overlap between the automated and manual segmentations. Results: The accuracy of the AI method was 0.96 for SAT and 0.94 for muscle. The average differences in volumes were significantly lower than the corresponding differences in areas in a single CT slice: 1.8% versus 5.0% (p < 0.001) for SAT and 1.9% versus 3.9% (p < 0.001) for muscle. The 95% confidence intervals for predicted volumes in an individual subject from the corresponding single CT slice areas were in the order of ± 20%. Conclusions: The AI-based tool for quantification of SAT and muscle volumes showed high accuracy and reproducibility and provided a body composition analysis that is more relevant than manual analysis of a single CT slice.

30 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
ETElin Trägårdh
Elin Trägårdh
OEOlof Enqvist
Olof Enqvist
JUJohannes Ulén
Johannes Ulén
JJJonas Jögi
Jonas Jögi
UBUlrika Bitzén
Ulrika Bitzén
LELars Edenbrandt
Lars Edenbrandt
Here, we aimed to develop and validate a fully automated artificial intelligence (AI)-based method for the detection and quantification of suspected prostate tumour/local recurrence, lymph node metastases, and bone metastases from [18F]PSMA-1007 positron emission tomography-computed tomography (PET-CT) images. Images from 660 patients were included. Segmentations by one expert reader were ground truth. A convolutional neural network (CNN) was developed and trained on a training set, and the performance was tested on a separate test set of 120 patients. The AI method was compared with manual segmentations performed by several nuclear medicine physicians. Assessment of tumour burden (total lesion volume (TLV) and total lesion uptake (TLU)) was performed. The sensitivity of the AI method was, on average, 79% for detecting prostate tumour/recurrence, 79% for lymph node metastases, and 62% for bone metastases. On average, nuclear medicine physicians’ corresponding sensitivities were 78%, 78%, and 59%, respectively. The correlations of TLV and TLU between AI and nuclear medicine physicians were all statistically significant and ranged from R = 0.53 to R = 0.83. In conclusion, the development of an AI-based method for prostate cancer detection with sensitivity on par with nuclear medicine physicians was possible. The developed AI tool is freely available for researchers.

25 September 2020 in Clinical Physiology and Functional Imaging
Verified
Journal Article
Closed access
PDF file
PBPablo Borrelli
Pablo Borrelli
MLMåns Larsson
Måns Larsson
JUJohannes Ulén
Johannes Ulén
OEOlof Enqvist
Olof Enqvist
ETElin Trägårdh
Elin Trägårdh
LELars Edenbrandt
Lars Edenbrandt

22 August 2019 in Clinical Physiology and Functional Imaging
Verified
Journal Article
Closed access
PDF file
MMMike Allan Mortensen
Mike Allan Mortensen
PBPablo Borrelli
Pablo Borrelli
MPMads Hvid Poulsen
Mads Hvid Poulsen
Oke GerkeOke Gerke
Oke Gerke
OEOlof Enqvist
Olof Enqvist
PHPoul Flemming Høilund‐Carlsen
Poul Flemming Høilund‐Carlsen

27 October 2016 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
PBPablo Borrelli
Pablo Borrelli
MDMaarten Lucas Donswijk
Maarten Lucas Donswijk
MSMarcel P. Stokkel
Marcel P. Stokkel
STSuzana C. Teixeira
Suzana C. Teixeira
HTHarm van Tinteren
Harm van Tinteren
RORenato A. Valdés Olmos
Renato A. Valdés Olmos
In recent years repeat sentinel node (SN) biopsy has been proven to be feasible in local breast cancer recurrence (LBCR). However, in these patients SNs outside the ipsilateral axilla are frequently observed. This study evaluates the contribution of SPECT/CT for SN localization and surgical adjustment in LBCR patients.

24 April 2024 in Osteoporosis and Sarcopenia
Verified
Journal Article
Open access
TYThomas Ying
Thomas Ying
PBPablo Borrelli
Pablo Borrelli
LELars Edenbrandt
Lars Edenbrandt
OEOlof Enqvist
Olof Enqvist
RKReza Kaboteh
Reza Kaboteh
HKHenrik Kjölhede
Henrik Kjölhede
Evaluation of sarcopenia from computed tomography (CT) is often based on measuring skeletal muscle area on a single transverse slice. Automatic segmentation of muscle volume has a lower variance and may be a better proxy for the total muscle volume than single-slice areas. The aim of the study was to determine which abdominal and thoracic anatomical volumes were best at predicting the total muscle volume. A cloud-based artificial intelligence tool (recomia.org) was used to segment all skeletal muscle of the torso of 994 patients who had performed whole-torso CT 2008–2020 for various clinical indications. Linear regression models for several anatomical volumes and single-slice areas were compared with regard to predicting the total torso muscle volume. The muscle volume from the tip of the coccyx and 25 cm cranially was the best of the abdominal volumes and was significantly better than the L3 slice muscle area (R2 0.935 vs 0.830, P < 0.0001). For thoracic volumes, the muscle volume between the top of the sternum to the lower bound of the Th12 vertebra showed the best correlation with the total volume, significantly better than the Th12 slice muscle area (R2 0.892 vs 0.775, P < 0.0001). Adjusting for body height improved the correlation slightly for all measurements but did not significantly change the ordering. We identified muscle volumes that can be reliably segmented by automated image analysis which is superior to single slice areas in predicting total muscle volume.