Dongsheng Wang

Dongsheng Wang

Auto-generated profile, based on publicly available information

Dongsheng Wang

College of Water Conservancy and Hydropower Engineering, Hohai University 4 , Nanjing 210098

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Physics of Fluids
Verified
Journal Article
Closed access
DWDongsheng Wang
Dongsheng Wang
TMTong Mu
Tong Mu
JFJiangang Feng
Jiangang Feng
RZRui Zhang
Rui Zhang
ZFZhaodan Fei
Zhaodan Fei
PZPeipei Zhang
Peipei Zhang
Axial-flow pumps have complex hydraulic performance under diverse conditions, especially under low-flow conditions, which may occur rotational stall and brings serious system vibration. By combining experiments and numerical simulation analysis, the fine features of the local internal flow field in multi-flow rate conditions are accurately reflected, revealing the mechanism of changes in the internal flow field and hydraulic performance of axial-flow pumps under different flow conditions, especially at low-flow conditions. As the flow rate decreased, the backflow velocity in near wall area of the inlet pipe and circumferential swirl velocity increased gradually, and the tip leakage vortex (TLV) and pressure surface vortex also increased gradually. Based on the average axial velocity V0 under the design flow rate, the axial backflow velocity was −1.18 V0 and the circumferential velocity was −3.53 V0 under the deep stall condition. The maximum vorticity of TLV, secondary vortex and pressure surface vortex was 5 × 106 S−2, and the area of maximum intensity was the largest. The interaction between the secondary vortices and the mainstream intensifies the formation and development of passage vortex and blocks the inlet pipe. Under the influence of comprehensive factors, the entropy production in the inlet channel and impeller region reached the maximum under the deep stall condition, both of which were above 22 × 10−2 kg m2 s−3 K−1, more than twice that outside the saddle zone. This study analyzed the flow instability under biased conditions from multiple levels and perspectives, providing a basis for improving the hydraulic performance under diverse flow conditions in the future.

1 August 2025 in Physics of Fluids
Verified
Journal Article
Open access
QGQiwen Gao
Qiwen Gao
SCShi Cheng
Shi Cheng
TMTong Mu
Tong Mu
QWQi Wang
Qi Wang
DWDongsheng Wang
Dongsheng Wang
Rectification optimization of the forebay in deflection-type inlet pumping stations mostly relies on a trial-and-error approach, which inevitably leads to resource wastage. To precisely improve the adverse flow patterns in the forebay, this study employs numerical simulations to reveal their formation mechanisms, establishes the intrinsic relationship between flow patterns and hydraulic characteristics, and proposes a targeted rectification measure—a “double-bottom sill + baffle plate” combination. The results indicate that five typical flow structures exist in the computational domain of the pumping station. Among them, the deflection mainstream, which has the most significant impact on the forebay, can be visually categorized into four zones: a concentrated-deflection zone, a gradient deflection zone, a low-speed zone, and a deflection–reflection zone. Helical flows and entrainment vortices predominantly occur in the concentrated-deflection zone, and deflection–reflection zone, localized at the forebay inlet, the degree change section, and the outlet, with intensity proportional to inflow condition. Helical flow intensity correlates with flow uniformity, while vortex strength links to local entropy generation. Energy loss at the forebay outlet shows a positive correlation with inflow condition. Post-rectification redistributes the flow velocity at the bottom sills and enhances the streamlined jet and destruct the vertical flow gradient, results show 36.36% higher flow uniformity, 8.14% less head loss, 1.79% lower turbulent kinetic energy, and 6.6% reduced dissipation rate. This study enhances the understanding of the distribution pattern of undesirable flow regimes in the forebay and provides practical guidance for analogous forebay design.