16 May 2024 in IEEE Transactions on Medical Imaging
Photon-counting computed tomography (PCCT) reconstructs multiple energy-channel images to describe the same object, where there exists a strong correlation among different channel images. In addition, reconstruction of each channel image suffers photon count starving problem. To make full use of the correlation among different channel images to suppress the data noise and enhance the texture details in reconstructing each channel image, this paper proposes a tensor neural network (TNN) architecture to learn a multi-channel texture prior for PCCT reconstruction. Specifically, we first learn a spatial texture prior in each individual channel image by modeling the relationship between the center pixels and its corresponding neighbor pixels using a neural network. Then, we merge the single channel spatial texture prior into multi-channel neural network to learn the spectral local correlation information among different channel images. Since our proposed TNN is trained on a series of unpaired small spatial-spectral cubes which are extracted from one single reference multi-channel image, the local correlation in the spatial-spectral cubes is considered by TNN. To boost the TNN performance, a low-rank representation is also employed to consider the global correlation among different channel images. Finally, we integrate the learned TNN and the low-rank representation as priors into Bayesian reconstruction framework. To evaluate the performance of the proposed method, four references are considered. One is simulated images from ultra-high-resolution CT. One is spectral images from dual-energy CT. The other two are animal tissue and preclinical mouse images from a custom-made PCCT systems. Our TNN prior Bayesian reconstruction demonstrated better performance than other state-of-the-art competing algorithms, in terms of not only preserving texture feature but also suppressing image noise in each channel image.
12 June 2024 in IEEE Transactions on Medical Imaging
In medical applications, the diffusion of contrast agents in tissue can reflect the physiological function of organisms, so it is valuable to quantify the distribution and content of contrast agents in the body over a period. Spectral CT has the advantages of multi-energy projection acquisition and material decomposition, which can quantify K-edge contrast agents. However, multiple repetitive spectral CT scans can cause excessive radiation doses. Sparse-view scanning is commonly used to reduce dose and scan time, but its reconstructed images are usually accompanied by streaking artifacts, which leads to inaccurate quantification of the contrast agents. To solve this problem, an unsupervised sparse-view spectral CT reconstruction and material decomposition algorithm based on the multi-channel score-based generative model (SGM) is proposed in this paper. First, multi-energy images and tissue images are used as multi-channel input data for SGM training. Secondly, the organism is multiply scanned in sparse views, and the trained SGM is utilized to generate multi-energy images and tissue images driven by sparse-view projections. After that, a material decomposition algorithm using tissue images generated by SGM as prior images for solving contrast agent images is established. Finally, the distribution and content of the contrast agents are obtained. The comparison and evaluation of this method are given in this paper, and a series of mouse scanning experiments are carried out to verify the effectiveness of the method.
27 May 2025 in IEEE Transactions on Circuits and Systems for Video Technology
The unstructured, unordered and inherent irregular sampling properties presents difficulties for accurate and efficient realizing semantic segmentation of large-scale 3D point cloud. The complexity and the long-distance information exploitation are the key challenges for large-scale 3D point cloud semantic segmentation. Therefore, in order to efficiently exploit long-distance global information and improve the segmentation accuracy of point cloud data located at the edges of distinct categories, a novel Trigonometric Bilinear attention and Global-aware Aggregation network (TBGA-Net) is designed to integrate and supplement the local-global contextual features for large-scale point clouds segmentation. The proposed Global-aware Context Aggregation block (GCA) can implicitly excavate the global context for each 3D point by utilizing its surface-to-volume ratio of the neighborhood to the global point cloud. Furthermore, aim at refining local-global features, the Trigonometric Bilinear Attention block (TBA) utilizes trigonometric functions to embed the point cloud coordinates of local regions, and applies bilinear attention to realize feature enhancement for obtaining more discriminative local-global features. Additionally, we further designed a novel Dynamic-adjusting Cross-entropy Loss (DCLoss) to incorporate with TBGA-Net for addressing the issue of class imbalance in training data for large-scale 3D point cloud semantic segmentation. The experimental results on three 3D point cloud datasets demonstrates that the proposed algorithm indicates better segmentation accuracy especially for the point located at the boundary of the distinct categories.
12 March 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
X-ray spectrum plays an essential role in CT applications. Since it is difficult to measure x-ray spectrum directly in practice, x-ray spectrum is always indirectly obtained by using transmission measurements through a calibration phantom of known thickness and materials. These methods are independent of CT image reconstruction and bring extra cost. To solve this problem, we propose a parametric physical model based x-ray spectrum estimation algorithm for CT imaging. First, an x-ray spectrum model with six parameters is proposed, which is derived from the x-ray imaging physics. Second, a template image containing different material components can be obtained by segmenting CT reconstructed images with a simple method. And the estimated projections can be calculated by reprojecting the template image with the proposed spectrum model. Finally, the six model parameters can be solved by iteratively minimizing the error between the estimated projection and real measurements. The effectiveness of the proposed method has been validated on both simulated and real data. Experimental results demonstrate that the proposed method can estimate the accurate spectra at different energies and provide a good reconstruction of characteristic radiations without extra cost.
16 January 2021 in Radiation Detection Technology and Methods
15 October 2024 in IEEE Transactions on Instrumentation and Measurement
Micro X-ray Fluorescence (μXRF) is a technology for non-destructive detection of elements with high resolution. Currently, the μXRF imaging system cannot scan with a fixed distance and incident angle, which highly affects the measurement consistency of curved objects. To solve this problem, we developed a novel Three-dimensional (3D) μXRF imaging system based on a robotic arm and a depth camera. In our system, the depth camera is used to capture both the coordinates and normal vectors of the contour of the object, while the μXRF spectrometer is installed on the six-axis robotic arm to flexibly scan the curved surface according to the contour. Compared to the existing systems, the proposed 3D μXRF imaging system eliminates the interference to the counts caused by the changes in the X-ray incident angle and distance, which improves the 3D imaging quality of curved surfaces. The highest resolution of the system can be controlled to within 50μm, and the single-point acquisition time can be as short as milliseconds. The alloy sample scanning experiment quantitatively demonstrated the fluctuation of the detector counts is only 0.62% within 18mm of the alloy sample surface, while the fluctuations of the other two scanning methods are 3.79% and 9.42%. The oil painting experiment validated the accuracy of the imaging system in element identification and imaging, by comparing it with ground truth. Teapot and cylinder experiments are performed to demonstrate the system’s capability for high-precision and high-resolution 3D imaging of objects in any orientation.