Joachim Sacher

Joachim Sacher

Auto-generated profile, based on publicly available information

Joachim Sacher

Sacher Lasertechnik GmbH (Germany)

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
TMTobias Milde
Tobias Milde
MHMorten Hoppe
Morten Hoppe
HTHerve Tatenguem
Herve Tatenguem
MMMario Mordmüller
Mario Mordmüller
JOJames O’gOrman
James O’gOrman
JSJoachim Sacher
Joachim Sacher
The measurement of trace gases has increasingly become a key technique in healthcare and other medical applications. Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a suitable method that can provide the required characteristics in such applications for a comparatively low cost and small size. The quantitative detection and a low detection limit are also required by applications. In this paper, we present new results on sensing biomedically relevant gases using the on-beam QEPAS technique with some newly developed tunable high-power single-mode laser diodes based on GaSb material. The data processing and detection limit determination are done by a field programmable gate array device, as well as an automatic measurement of the resonance frequency.

29 June 2006 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
SSS. Stry
S. Stry
STS. Thelen
S. Thelen
JSJ. Sacher
J. Sacher
DHD. Halmer
D. Halmer
PHP. Hering
P. Hering
MMM. Mürtz
M. Mürtz

1 June 2015 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
SRSimon Rauch
Simon Rauch
JSJoachim Sacher
Joachim Sacher
A single ridge waveguide laser wavelength stabilized by a compact external Bragg grating cavity with an output power as much as 380 mW and a beam quality factor M2 of 1.3 is presented. A characterization concerning tunability by current, short-term optical linewidth, and intensity fluctuations is performed. The device exhibits a wavelength tuning factor at 780 nm of 0.5 pm/mA, a short-term optical linewidth of 18 kHz, and a low-frequency relative intensity noise of -136 dB/Hz. These characteristics allow a high resolution absorption spectroscopy of the D2 line of rubidium.

4 July 2017 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
AJA. Jiménez
A. Jiménez
TMT. Milde
T. Milde
NSN. Staacke
N. Staacke
CAC. Aßmann
C. Aßmann
GBGUILLERMO CARPINTERO DEL BARRIO
GUILLERMO CARPINTERO DEL BARRIO
JSJ. Sacher
J. Sacher

8 September 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
TMTobias Milde
Tobias Milde
CAChristian Assmann
Christian Assmann
AJAlvaro Jimenez
Alvaro Jimenez
MHMartin Honsberg
Martin Honsberg
JOJames O’gOrman
James O’gOrman
JSJoachim Sacher
Joachim Sacher
The wavelength, λ, range of 1.8  μm≤λ≤3.5  μm contains strong spectral absorption lines of many gases used in health, industry, safety, and medicine and whose sensitive and quantitative detection is desirable. However, the performance of InP diode lasers markedly deteriorates beyond λ∼2  μm. In this paper we present new results on developing tunable high power single mode laser diodes based on the GaSb material system with emission in the wavelength range of 1.8  μm≤λ≤2.2  μm.

27 September 2024 in Science Advances
Verified
Journal Article
Open access
LLLukas Lindner
Lukas Lindner
FHFelix A. Hahl
Felix A. Hahl
TLTingpeng Luo
Tingpeng Luo
GAGuillermo Nava Antonio
Guillermo Nava Antonio
XVXavier Vidal
Xavier Vidal
JJJan Jeske
Jan Jeske
Diamond is a potential host material for laser applications due to its exceptional thermal properties, ultrawide bandgap, and color centers, which promise gain across the visible spectrum. More recently, coherent laser methods offer improved sensitivity for magnetometry. However, diamond fabrication is difficult in comparison to other crystalline matrices, and many optical loss channels are not yet understood. Here, we demonstrate a continuous-wave laser threshold as a function of the pump intensity on nitrogen-vacancy (NV) color centers. To achieve this, we constructed a laser cavity with both an NV diamond medium and an intracavity antireflection-coated diode laser. This dual-medium approach compensates intrinsic losses of the cavity by providing a fixed additional gain below threshold of the diode laser. We observe a continuous-wave laser threshold of the laser system and linewidth narrowing with increasing green pump power on the NV centers. Our results are a major development toward coherent approaches to magnetometry.