Lijuan Huang

Lijuan Huang

Auto-generated profile, based on publicly available information

Lijuan Huang

School of Electronic and Information Engineering, South China Normal University, Foshan, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
WSWeiheng Shao
Weiheng Shao
YCYinghui Chen
Yinghui Chen
LHLijuan Huang
Lijuan Huang
WFwenxiao FANG
wenxiao FANG
Symmetry are a critical assumption and an application barrier in a two-port near-field probing system before the asymmetric calibration was proposed. Asymmetric calibration can break through this barrier and benefit probe design and application expansion. In this communication, a novel asymmetric correction method has been proposed to compensate for the influence of the asymmetry element, which is inserted into one side of the probing system. Different from the traditional ultrawideband asymmetric calibration method that highly depends on the symmetry of the calibrator, the proposed method can achieve asymmetry correction using the S-parameter of a symmetric two-port probe and the asymmetric element. The efficiency of the asymmetric correction method is proven by three typical asymmetric measurements, inserting a connector, an attenuator, and a cable. The verified measurement frequency range of the proposed asymmetric correction method is up to 20 GHz.

5 February 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LHLijuan Huang
Lijuan Huang
JLJinfu Liao
Jinfu Liao
ZHZhanjun Huang
Zhanjun Huang
WSWeiheng Shao
Weiheng Shao
YCYan Chen
Yan Chen
JWJianying Wang
Jianying Wang
In this paper, an ungrounded double-loop active differential magnetic field probe is proposed. The proposed probe includes two low noise amplifiers and an ungrounded double-loop detection structure, which can ensure a high magnetic field response. The detection structure also includes a shielded ground plate for suppressing electric field coupling and improving the common-mode rejection ratio (CMRR). Meanwhile, a rotate asymmetric calibration method (RACM) is used to correct the probing system’s asymmetry, improve the CMRR, and broaden the measurement frequency range. Therefore, the probing system combines several advanced design ideas, including adding two amplifiers, designing an ungrounded double-loop detection structure with shielded ground plate, using the asymmetric calibration method, and reserving differential output. The calibration data show that the proposed probe has a high magnetic field response factor of -19.8 dB at 2 GHz and a suppressed electric field response factor below -90 dB at 2 GHz. After using the RACM, a CMRR of more than 31.8 dB can be obtained when the frequency is less than 9 GHz. When the frequency is up to 14 GHz, the CMRR is better than 16 dB. The validation results of measuring three stand-wave points prove that the proposed probe and probing system can realize radio frequency magnetic field detection along a trace of up to 14 GHz.

13 December 2023 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
XHXiao He
Xiao He
LHLijuan Huang
Lijuan Huang
DZDezhi Zeng
Dezhi Zeng
BHBo Hou
Bo Hou
YCYuan Chi
Yuan Chi
ELEn Li
En Li
The asymmetric calibration method is a very interesting technology for differential output probes. It has been proven that the asymmetric calibration method (ACM) can broaden the application scenarios of the electromagnetic field dual probe. However, ACM is not verified on a back‐to‐back double‐loop differential magnetic field probing system. This paper calibrates a back‐to‐back double‐loop differential magnetic field probing system by inserting a connector for creating an asymmetry using ACM. The calibration results show that ACM can be used to calibrate an asymmetric back‐to‐back double‐loop differential magnetic field probing system. The calibration results are further verified by measuring the standing wave magnetic field, and the verification results show that the asymmetric calibration method is effective in eliminating the asymmetry of the back‐to‐back double‐loop differential magnetic field probing system and the work frequency band reaches up to 12 GHz.