We present a first implementation of optical-frequency-comb-based rapid trace gas detection in the molecular fingerprint region in the mid-infrared. Near-real-time acquisition of broadband absorption spectra with 0.0056 cm−1 maximum resolution is demonstrated using a frequency comb Fourier transform spectrometer which operates in the 2100-to-3700-cm−1 spectral region. We achieve part-per-billion detection limits in 30 seconds of integration time for several important molecules including methane, ethane, isoprene, and nitrous oxide. Our system enables precise concentration measurements even in gas mixtures that exhibit continuous absorption bands, and it allows detection of molecules at levels below the noise floor via simultaneous analysis of multiple spectral features.
We overcome the resolution limit of Fourier-transform spectrometry and measure instrumental line-shape-free broadband molecular spectra with lines narrower than the optical path-limited resolution. We do this by using an optical frequency comb and precisely matching the maximum delay range of the spectrometer to the comb line spacing to measure the intensities of the individual comb lines. This method allows measurements of undistorted high-resolution spectra with acquisition time and interferometer length reduced by orders of magnitude and with frequency scale accuracy given by the comb.
We achieve a quantum-noise-limited absorption sensitivity of per spectral element at 400 s of acquisition time with cavity-enhanced frequency comb spectroscopy, the highest demonstrated for a comb-based technique. The system comprises a frequency comb locked to a high-finesse cavity and a fast-scanning Fourier transform spectrometer with an ultralow-noise autobalancing detector. Spectra with a signal-to-noise ratio above 1000 and a resolution of 380 MHz are acquired within a few seconds. The measured absorption line shapes are in excellent agreement with theoretical predictions.
1 January 2018 in Journal of Quantitative Spectroscopy and Radiative Transfer
Broadband precision spectroscopy is indispensable for providing high fidelity molecular parameters for spectroscopic databases. We have recently shown that mechanical Fourier transform spectrometers based on optical frequency combs can measure broadband high-resolution molecular spectra undistorted by the instrumental line shape (ILS) and with a highly precise frequency scale provided by the comb. The accurate measurement of the power of the comb modes interacting with the molecular sample was achieved by acquiring single-burst interferograms with nominal resolution matched to the comb mode spacing. Here we describe in detail the experimental and numerical steps needed to achieve sub-nominal resolution and retrieve ILS-free molecular spectra, i.e. with ILS-induced distortion below the noise level. We investigate the accuracy of the transition line centers retrieved by fitting to the absorption lines measured using this method. We verify the performance by measuring an ILS-free cavity-enhanced low-pressure spectrum of the 3ν1 + ν3 band of CO2 around 1575 nm with line widths narrower than the nominal resolution. We observe and quantify collisional narrowing of absorption line shape, for the first time with a comb-based spectroscopic technique. Thus retrieval of line shape parameters with accuracy not limited by the Voigt profile is now possible for entire absorption bands acquired simultaneously
Optical frequency combs offer enormous potential in the detection and control of atoms and molecules by combining their vast spectral coverage with the extremely high spectral resolution of each individual comb component. Sensitive and multiplexed trace gas detection via cavity-enhanced direct frequency comb spectroscopy has been demonstrated for various molecules and applications; however, previous demonstrations have been confined to the visible and near-infrared wavelength range. Future spectroscopic capabilities are created by developing comb sources and spectrometers for the deep ultraviolet and mid-infrared spectral regions. Here we present a broadband high resolution mid-infrared frequency comb-based Fourier transform spectrometer operating in the important molecular fingerprint spectral region of 2100–3600 cm−1 (2.8–4.8 μm). The spectrometer, employing a multipass cell, allows simultaneous acquisition of broadband, high resolution spectra (down to 0.0035 cm−1) of many molecular species at concentrations in the part-per-billion range in less than 1 min acquisition time. The system enables precise measurements of concentration even in gas mixtures that exhibit continuous absorption bands. The current sensitivity, 2 × 10−8 cm−1Hz−1/2 per spectral element, is expected to improve by two orders of magnitude with an external enhancement cavity. We have demonstrated this sensitivity increase by combining cavity-enhanced frequency comb spectroscopy with a scanning Fourier transform spectrometer in the near-infrared region and achieving a sensitivity of 4.7 × 10−10 cm−1Hz−1/2. A cavity-enhanced mid-infrared comb spectrometer will provide a near real-time, high sensitivity, high resolution, precisely frequency calibrated, broad bandwidth system for many applications.