Muhammad Haziq Mohd Wazir

Muhammad Haziq Mohd Wazir

Auto-generated profile, based on publicly available information

Muhammad Haziq Mohd Wazir

Centre of Electrical Energy Systems, Institute of Future Energy, Universiti Teknologi Malaysia, Skudai, Malaysia

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
MWMuhammad Haziq Mohd Wazir
Muhammad Haziq Mohd Wazir
DSDalila Mat Said
Dalila Mat Said
ZYZaris Izzati Mohd Yassin
Zaris Izzati Mohd Yassin
SWSiti Aisyah Abd Wahid
Siti Aisyah Abd Wahid
In an electrical power distribution system, harmonic distortion is the most prominent power quality problem that causes long-term adverse effects such as failure of distribution transformers. Considering that most transformer problems are caused by heat losses due to the presence of harmonics, it was decided to use a numerical method with the highest accuracy, finite element method (FEM) to analyze the hot spot temperature (HST) of the thermal distribution transformer model. Through the use of COMSOL Multiphysics software, three phases of unbalanced harmonic loads are considered, which contribute to three different total harmonic distortion current (THDI) levels and five different insulation temperature classes. Using the IEEE C57.110-2018 guidance, the simulation outputs are then verified with HST results from the HST mathematical model. The findings indicated that with the increased loadings, the unbalanced harmonic currents have impacted the HST increment and distinguished the HST values between the phases.

18 March 2025 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
MWMuhammad Haziq Mohd Wazir
Muhammad Haziq Mohd Wazir
DSDalila Mat Said
Dalila Mat Said
NSNorazliani Md Sapari
Norazliani Md Sapari
MYMohamed Shahriman Mohamed Yunus
Mohamed Shahriman Mohamed Yunus
ZYZaris Izzati Mohd Yassin
Zaris Izzati Mohd Yassin
Elevated winding insulation temperature, driven by harmonic distortions, is a key factor in transformer lifespan reduction. Conventional models often oversimplify the effect of combined current and voltage harmonics. This paper proposes an electro-thermal modeling approach, incorporating dual heat sources from core and winding domains, to enhance HST estimation in distribution transformers affected by photovoltaic-induced (PV)-induced harmonic losses. A sophisticated numerical approach, Finite Element Analysis (FEA), is employed using COMSOL Multiphysics software, with a 250-minute time-dependent study assessing thermal effects. The results, verified against a mathematical model approach based on IEEE C57.110-2018 guidance, demonstrate that higher levels of harmonics lead to a rapid increase in HST, accelerating the time to reach the aging factor temperature and consequently diminishing the transformer’s operational lifespan. Specifically, the per-unit life of the transformer decreases from 0.219 in Case 1 to 0.154 in Case 2 and 0.027 in Case 3, while the aging acceleration factor increases from 4.310 to 5.683 and 21.7, respectively. The methods showed over 95% alignment with the mathematical modeling approach, confirming the model’s precision in its predictive capability. The novelty of this study lies in its enhanced electro-thermal framework, which overcomes the limitations of conventional methods by integrating dual heat sources and providing a refined assessment of transformer aging under harmonic distortions. This advancement offers a more precise and computationally efficient approach for assessing transformer thermal stress under harmonic distortions.