Paul Beckett

Paul Beckett

Auto-generated profile, based on publicly available information

Paul Beckett

School of Engineering, RMIT University 3 , Melbourne, VIC 3000, Australia

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in APL Photonics
Verified
Journal Article
Open access
PDF file
XHXIN HE
XIN HE
YLYajing Liu
Yajing Liu
KGKumar Ganesan
Kumar Ganesan
IAI arman Ahnood
I arman Ahnood
PBPaul Beckett
Paul Beckett
RURanjith Unnithan
Ranjith Unnithan
A multispectral image camera captures image data within specific wavelength ranges in narrow wavelength bands across the electromagnetic spectrum. Images from a multispectral camera can extract a additional information that the human eye or a normal camera fails to capture and thus may have important applications in precision agriculture, forestry, medicine, and object identification. Conventional multispectral cameras are made up of multiple image sensors each fitted with a narrow passband wavelength filter and optics, which makes them heavy, bulky, power hungry, and very expensive. The multiple optics also create an image co-registration problem. Here, we demonstrate a single sensor based three band multispectral camera using a narrow spectral band red–green–blue color mosaic in a Bayer pattern integrated on a monochrome CMOS sensor. The narrow band color mosaic is made of a hybrid combination of plasmonic color filters and a heterostructured dielectric multilayer. The demonstrated camera technology has reduced cost, weight, size, and power by almost n times (where n is the number of bands) compared to a conventional multispectral camera.

22 July 2016 in IEEE Transactions on Emerging Topics in Computing
Verified
Journal Article
Closed access
NNNastaran Nemati
Nastaran Nemati
PBPaul Beckett
Paul Beckett
MRMark C. Reed
Mark C. Reed
KFKarl Fant
Karl Fant
Null Convention Logic (NCL) is a robust asynchronous technique that poses new challenges to test and testability strategies due to the lack of a clock signal and the state-holding behavior of the NCL gates. The lack of deterministic timing in NCL complicates the management of test timing, and stuck-at faults on gate internal feedback (GIF) of the NCL gates exhibit a totally different effect compared to that of stuck-at faults on the gate inputs. Stuck-at faults on gate internal feedback of NCL gates do not always cause an incorrect output and therefore are considered hard-to-detect or undetectable by automatic test pattern generation (ATPG) algorithms. Such faults could leave the primary outputs of the circuit completely unaffected or sometimes they only affect the circuit by early detection of completeness. This work first proposes a clock-less self-timed ATPG, with no added design for test (DFT), that detects all of the faults on the gate inputs and a share of those on the GIF of gates. Then, this work investigates the effectiveness of IDDQ (quiescent current) test for detecting stuck-at faults on GIF of NCL gates. Hspice is used for implementing static and semi-static transistor-level NCL gates in (45nm, 1.1V) technology, for which the supply current is measured and compared for fault-free and faulty circuits. The experimental results show that the faulty current is orders of magnitude higher than the fault-free leakage current. This considerable difference shows that IDDQ testing might be an efficient and low-cost candidate for detecting stuck-at faults on GIF of NCL gates. The proposed IDDQ test method along with the self-timed ATPG has resulted in average 98.16% and 98.04% fault coverage for static and semi-static implementations of several NCL circuits, respectively. To the extent of our knowledge, this is the first work that has addressed clock-less, self-timed ATPG for NCL with no area overhead, and also the first work conducted on IDDQ test for NCL.

11 August 2016
Verified
Conference Paper
Closed access
NNNastaran Nemati
Nastaran Nemati
MRMark C. Reed
Mark C. Reed
KFKarl Fant
Karl Fant
PBPaul Beckett
Paul Beckett
This work proposes asynchronous interleaved scan architecture (AISA) intended for the internal structure of online Built-in Self-test for Null Convention Logic (NCL) circuits. NCL is a robust asynchronous paradigm which can target devices for long-life missions and hard-to-access environments. However, on-line self-test methods adapted to match the characteristics of this important asynchronous method are not available currently. Existing test hardware for NCL is based on synchronous test elements. Such test hardware when used for on-line testing could introduce metastability issues and reduce the reliability of the highly robust NCL devices. We propose a scan architecture specifically designed for NCL circuits and demonstrate how this can be integrated into an on-line BIST architecture. Results for timing of the scan cell are shown with an average area overhead of 10%, which is only 35% of that of previous work [1]. Furthermore we do not need clock trees or double latches for sync/async interfaces.

1 December 2015
Verified
Conference Paper
Closed access
KHKashfia Haque
Kashfia Haque
CJConrad Jakob
Conrad Jakob
RSRenuka Sovani
Renuka Sovani
PBPaul Beckett
Paul Beckett
We present the design and organization of an homogeneous asynchronous bit-level array based on Null Convention Logic. A bit element (bel) array represents a bit-level hybrid processor that exhibits both Spatial and Temporal computing characteristics. The bit elements are organized in a 2D grid, with eight-way connectivity. Programs represented as Directed Acyclic Graphs can be mapped to the array either fully statically or with a small level of element reuse (dynamic mapping).

19 October 2018 in IEEE Photonics Journal
Verified
Journal Article
Open access
MSMiao Sun
Miao Sun
Omid KaveheiOmid Kavehei
Omid Kavehei
PBPaul Beckett
Paul Beckett
ARAnn Roberts
Ann Roberts
WSWilliam Shieh
William Shieh
RURanjith Unnithan
Ranjith Unnithan
Plasmonic filters are excellent candidates for spectral filters in the near infrared spectrum. Such filters require only a single nanoscale thickness perforated metal film that can be tailored to tune the location of the transmission maximum. Here, we demonstrate using computational methods a double coaxial aperture array (DAA) in a hexagonal geometry that can be tuned to produce plasmon resonances accompanied by strong transmission in the nearinfrared spectrum and at telecommunication wavelengths with a peak wavelength insensitive to angle of incidence. The DAA consists of two concentric annular apertures and radial distance between the two apertures is varied to tune the resonant wavelength. The presented geometry finds potential applications in modulators for telecommunication, spectroscopy, solar cells, highresolution CMOS image sensors, chemical sensors and biosensors.