1 December 2016 in IEEE Transactions on Dielectrics and Electrical Insulation
The insulation structure of the UV-preionization gas switch for LTDs (Linear Transformer Drivers) has been designed in this study. The surface discharge along the gas switch chamber surface problem has been studied to ensure the gas switch can be charged to 200 kV DC. Meanwhile, the structure of the gas switch ought to be designed compact, in order to lower the overall inductance of the UV-preionization gas switch for LTD. It has been found that surface discharge is most likely to occur at the connection part of the solid dielectric, the electrodes and the air according to the electric field intensity simulation by a two-dimensional electrostatic solver. Polycarbonate (PC) has been selected as the insulator for the gas switch by analyzing the electric field distortion extent and the machinery strength of the various kinds of insulators. A surface discharge experiment has been designed. The experiment measures the surface discharge voltage in various distinct conditions of the surface roughness, the surface discharge distance and the gas pressure etc. In analogy to the air breakdown voltage empirical formula (U=f(pd)), we fitted the surface discharge voltage formula for the product of surface discharge distance and the gas pressure. The chamber surface has been grooved since the surface discharge distance has to be lengthened. It has been found that the measure of raising the grooving width is more effective than the measure of raising the grooving length in preventing the surface discharge when comparing the experimental results of these two different grooving methods.
27 September 2022 in IEEE Transactions on Plasma Science
The temperature is closely related to the operating state of the thyristors in repetitive pulsed power applications. To study the thermal behaviors of the thyristor at high blocking voltage and repetition discharge frequency, the thermal calculation model, including the electrothermal model and the finite-element method (FEM) model, is established. The model is based on the practical conditions, the internal structure of the thyristor, and the heat transfer mechanism and is validated by comparing the experimental and calculation results. By the model, the transient junction temperature variation and the mathematical model among blocking voltage, repetition frequency, and junction temperature are obtained. The model presented is capable of evaluating the thermal behaviors, calculating the junction temperature of the thyristors in repetitive pulsed power applications, and providing optimal suggestions for the reliable operation of the pulsed power sources.
1 September 2018 in Review of Scientific Instruments
This paper presents a low-jitter, low-trigger-threshold, high-dielectric-constant ceramic, plasma-triggered gas switch developed for pulsed power generators. We also discuss the principles behind the switch and the experiments and numerical calculations used. The electron emission and surface flashover in the trigger structure are used to create the initial plasma for switch breakdown. The experimental results show that the switch is triggered stably with a negative pulse of −50 kV peak and has a breakdown delay time jitter of 2–3 ns. In this jitter performance, the switch has a switch coefficient below 20%, and a peak current-carrying ability of at least ±5 kA in dry air at atmospheric pressure. The switch can also be reliably triggered with a switch coefficient of 49.7% and an over-voltage ratio of only 0.16 in dry air.