The temperature is closely related to the operating state of the thyristors in repetitive pulsed power applications. To study the thermal behaviors of the thyristor at high blocking voltage and repetition discharge frequency, the thermal calculation model, including the electrothermal model and the finite-element method (FEM) model, is established. The model is based on the practical conditions, the internal structure of the thyristor, and the heat transfer mechanism and is validated by comparing the experimental and calculation results. By the model, the transient junction temperature variation and the mathematical model among blocking voltage, repetition frequency, and junction temperature are obtained. The model presented is capable of evaluating the thermal behaviors, calculating the junction temperature of the thyristors in repetitive pulsed power applications, and providing optimal suggestions for the reliable operation of the pulsed power sources.
The merits of fast conduction, rapid dielectric recovery, high reliability, and compact construction make the electrically triggered vacuum surface flashover switch (VSFS) suitable for high-pulsed power technology. The trigger delay is an important parameter to describe the performance of VSFS. This article focuses on the trigger delay of a coaxial VSFS. Based on the secondary electron emission avalanche (SEEA) model, the trigger process of VSFS was analyzed in this article. A quantitative calculation method is proposed, which includes the electron emission at the vacuum–metal–dielectric triple junction, saturated secondary electron emission (SSEE), the desorbed gas diffusion on the surface of dielectric, plasma channel resistance collapse, and plasma diffusion. The influence factors of trigger delay are revealed through calculation, which could determine the optimum operating mode of the switch. Finally, the trigger delay of VSFS is tested, and the experimental results are consistent with the calculated results.
The high proportion of renewable energy connected to the grid has resulted in insufficient consumption capacity in distribution networks, while the construction of new-type power distribution systems has imposed higher reliability requirements. With its flexible power synchronization control capabilities, grid-forming energy storage systems possess the ability to both promote the consumption of distributed energy resources in new-type distribution networks and enhance their reliability. However, current control methods are still hindered by drawbacks such as high computational complexity and a singular optimization objective. To address this, this paper proposes an optimized strategy for unified active–reactive power coordinated control in high-proportion renewable energy distribution networks with the participation of multiple grid-forming energy storage systems. Firstly, to optimize the parameters of grid-forming energy storage systems more accurately, this paper employs an improved iterative self-organizing data analysis technique algorithm to generate typical scenarios consistent with the scheduling time scale. Quantile regression (QR) and Gaussian mixture model (GMM) clustering are utilized to generate typical scenarios for renewable energy output. Subsequently, considering operational constraints and equipment state constraints, a unified active–reactive power coordinated control model for the distribution network is established. Meanwhile, to ensure the optimality of the results, this paper adopts an improved northern goshawk optimization (NGO) algorithm to solve the model. Finally, the effectiveness and feasibility of the proposed method are validated and illustrated through an improved IEEE-33 bus test system tested on MATLAB 2024B. Through analysis, the proposed method can reduce the average voltage fluctuation by 6.72% and increase the renewable energy accommodation rate by up to 8.64%.
7 November 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Electrically triggered vacuum surface flashover switches (VSFS) offer the advantages of rapid closure, high pulsed repetition frequency, high reliability, and compact design for high pulse power technology. The output performance of the pulsed power system, as well as the lifetime of VSFS, is limited by the plasma impedance during the VSFS turn-on process. This paper presents a theoretical calculation of the plasma impedance based on experimental measurements and second-order Taylor series, and the mathematical expressions of plasma impedance and ohmic loss are performed. From the experimental waveform and the theoretical calculation of the expression, the variation curve of the plasma impedance is derived. Lastly, the influencing factors (operating voltage, loop resistor, discharge capacitor, trigger resistor, and trigger voltage) are investigated. The experimental results indicate that an increase in operating voltage can increase the plasma resistance drop rate and can reduce the plasma ohmic loss. The same trend is also achieved by decreasing the loop resistor. Moreover, the discharge capacitance, trigger voltage, and trigger current only affect the on-state stage and the trigger process, and the impact on the plasma resistance and ohmic loss during the closing process is weak.